To set up the o nline netw o rk
TheonlinenetworkfortheexampleinFigure C10 looksasinFigureC12.Thetwo
thermostats 102 and 103 must be set up under the same parent in the network,
i.e. be set up in the same PAN (personal area network). To set up the network,
follow the steps below:
1. Open SysMon (Syst em Monit or) whic h is used for managing the online net work;
double c lic k on SysMon.exe in the VISIONLINE inst allat ion folder.
2. Log on to SysMon; go to File/Log on and enter user ID and password. At
'Operator card', choose the applicable card encoder and click Enter.
3. Go to View/Online Network to show the Online Network tree.
4. Install the gateway; see User manual Online option for details.
5. Initialize thermostat 102 with 'normal parameters', i.e. all parameters except for
those related to suite. To do this, use the Initialize alternative in Orion Servic e
but leave the Suite settings empty. See Quic k referenc e guide Orion Servic e
for det ails about Initialize.
6. Connec t thermostat 102 to the gateway; see chapter 4
for details.
7. Connec t motion sensor 102 to thermostat 102;seechapter 4
for details.
8. Connec t loc k 102 to thermostat 102;seechapter 4
for details.
9. Repeat steps 5-8 for the devices in room 103.
10. Initialize thermostat 102 with suite settings; click here
for details.
11. Read out the thermostat status for thermostat 102; c lic k here
for details.
12. Read out the thermostat status for thermostat 103; c lic k here
for details.
13. See the final Online Network tree in Figure C16
.
Figure C12