DRAFT 66 8003 001-8
2.1.2 Thermostat display
Figure 14
Note: After some seconds of inactivity of the thermostat buttons,
the display will shut down. The first key press of any button will
activate the display again, and then the buttons work as normal
until the next inactivity timeout occurs.
Note: Some of the indicators are not yet implemented in
the thermostat firmware and therefore not described in the
below table.
Display indicator
Description
1
Temperature
The temperature display area shows the actual room temperature or the
setpoint temperature as well as the indication of Fahrenheit or Celsius.
What to display is configured when setting up the thermostat profile for the
concerned thermostat; choose 'Set temperature' or 'Room temperature' under
the Misc alternative in the Thermostat profile details dialog of VISIONLINE,
see Figure 15. If 'Room temperature' is chosen, the thermostat
will still display the set temperature for a few seconds when the guest uses
the Increase/Decrease temperature buttons. The thermostat will then revert to
show the room temperature again. When the displayed temperature is the guest
setting and not the actual room temperature, the SET indicator is also displayed.
2
Heat/Cool
The thermostat displays universal icons for heating and cooling.
The snow star is the symbol to indicate the unit is in cooling mode
and the sun is the symbol to indicate heating mode.
3
Fan
The Fan indicator shows the fan speed of the unit. As the fan speed increases,
additional segments or the indicator are displayed. When in AUTO fan mode,
the word AUTO will appear at the Miscellaneous indicator, see below.
4
Miscellaneous
The Miscellaneous indicator is a multi-purpose indicator; it e.g. displays
the word AUTO when the automatic fan mode is enabled.
5
Wrench
The Wrench indicator is displayed when maintenance is required on any
of the Orion EMS devices in the room or on the HVAC unit. This icon is
only displayed to hotel staff. To get the details of the maintenance needed,
connect the service cable to the thermostat and choose the Status alternative
in Orion Service.
6
Battery
The Battery indicator is displayed to hotel staff when the batteries are
low (on battery powered units) and in need of replacement. Note: This is
a low indicator only, not a segmented icon that displays the battery level.
As soon as this indicator is displayed, the batteries need to be replaced.
Note: If the lock is not used to monitor the door status, the service
indicators will only be displayed when the service cable is connected
to the thermostat and Orion Service is used.
Table 8