50
DRAFT 66 8003 001-8
Appendix A
Orion Thermostat-Zen-HV
Dimensions (WxHxD)
112 x 117 x 35 mm (4 13/32" x 4 19/32" x 1 3/8")
Input voltage
100-277VAC; 50/60 Hz
Switch input
Door switch - 1 exterior/1 interior
Multifunction input
Motion sensor/card switch/pipe temp sensor
High voltage outputs
- W/W2 (heating; max 0.5A
- Y/W2 (cooling/compressor; max 0.5A)
- RV (reversing valve; max 0.5A
- G1 (Fan 1; max 3A)
- G2 (Fan 2; max 3A)
- G3 (Fan 3; max 3A)
Low voltage outputs
- Proportional 0-10V; heating
- Proportional 0-10V; cooling
- Relay output (max 30V AC/DC, max 100mA)
Temperature sensor
Integrated in thermostat
Material
ABS
Required VISIONLINE version
1.14.0 or higher
Required Orion Service version
1.2.5 or higher