3.4.5 Timeout
1. At Ext. door timeout, choose
between
normal;default
short;20seconds
2. At Room not occupied,enter
the applic able number of minutes
(default is 8) after which t imeout
should occur. If 'Normal' is chosen
at Ext. door timeout, the HVAC
will turn off if the exterior door is
left open for t his period of time.
3. At Room not sold,enterthe
applicable number of hours
(default is 16) after which an
unoccupied room should enter the
unsold mode.
Note:
If the PMS system sends
a c heck-out c ommand, the
Room not sold parameter will be
overridden and timeout will
immediately take place.
Figure 63
3.4.6 Deadband
1. At Thermostat,enterthe
applicable number of degrees;
default is 2 ºF.
2. At Heat/cool,enterthe
applicable number of degrees;
default is 3 ºF.
Figure 64