12.4.3.22.4 Out of range failure 'R'
The block address of the 'w' command is higher than 40h.
The block address of the 'w' command conflicts with other commands, therefore the
block address has to be limited to 40h.
Use the 'wb' command instead.
12.4.3.23 Write EEPROM
Writes to the internal reader EEPROM. It contains all start-up parameters and the
device ID. Changes to the start-up settings will only go into effect after a reset of the
device.
Command
Command Data
'wp' Address (1 byte), valid range 0Ah - EFh
Data (1 byte)
Answer
Answer Description
Data EEPROM data (1 byte)
'F' Error: Read after write failure
'R' Error: Out of range failure
Example
Command Description
wp0A01 Set EEPROM address 0A (Station ID) to 01h
12.4.3.23.1 Out of range failure 'R'
The entered address exceeds the address range.