User Manual Model: HCP Lshape ZW3 ANZ / HCP Lshape ZW3 EMEA/ HCP Lshape ZW3 KR
Table of Contents 1 FEATURES & SPECIFICATIONS ........................................................................................................................3 1.1 HARDWARE CHARACTERISTICS ...........................................................................................................................3 1.2 SOFTWARE CHARACTERISTICS ............................................................................................................................3 2 PRODUCT QUICK START .............
1 FEATURES & SPECIFICATIONS 1.1 Hardware Characteristics Parameter Value Z-Wave Module ZGM130S Z-Wave Antenna Distance 40m (Indoor) /150m (Outdoor) Input Voltage 3.6-6.0V from the lock Working Current RX: 9.8 mA TX: 13.3 mA Standby Current 0.8μA 1.2 Software Characteristics Parameter Value Wireless Technology Z-Wave Certification Type Z-Wave Plus v2 Z-Wave SDK Version 7.16.
Association Support. Refer to Section 3.2 Association Group Info. Factory Reset Support. Refer to Section 2.5 How to factory reset. Power-down Memory Support. All command settings will stay unchanged even power down. Timed battery report Support. Low battery warning Support. Door State Report Support. When door lock mode changed, send out notification via Group 1. Note: Z-Wave 700 Module cannot be used independently. It should be used with the lock ( Yale).
2 PRODUCT QUICK START 2.1 What is Z-Wave Z-Wave is the international wireless protocol for communication in the Smart Home. Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
3 SOFTWARE FUNCTION DEFINITION 3.
Multi-Channel Association 3 S0 or Access Control Powerlevel 1 S0 or Access Control Security 0 1 None Security 2 1 None Supervision 1 None Transport Service 2 None 3 S0 or Access Control 1 None Version Application Status Configuration 4 S0 or Access Control Door Lock Logging 1 S0 or Access Control 8 S0 or Access Control 3 S0 or Access Control 1 S0 or Access Control 2 None 2 S0 or Access Control 2 None Notification Schedule Entry Lock Time Parameter Time User Code Z-Wave
3.4 Z-Wave Plus Info The Command is used to differentiate between Z-Wave Plus, Z-Wave for IP and Z-Wave devices. This command provides additional information about the Z-Wave Plus device in question.
3.5 Version The Command may be used to obtain the Z-Wave library type, the Z-Wave protocol version used by the application, the individual command class versions used by the application. Parameter Value Z-Wave Protocol Library Type 0x03 Z-Wave Protocol Version 0x07 Z-Wave Protocol Sub Version 7.16.3 Firmware 0 Version 0x02 Firmware 0 Sub Version 0x26 Firmware 1 Version 0x0B Firmware 1 Sub Version 0x0B Hardware Version 0x02 Number of additional firmware targets 0x01 3.
3.6.1 Grouping identifier 1 3.6.
3.7 Devices from Multiple Manufactures This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufactures. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. 3.