Regular Arm Installation
Closer installs on PUSH/STOP
side of door.
Surface Mounted
Adjustable & Preset "Back-Check"
900 Series
No Hold-Open/Hold-Open
Optional BF/DA
Top View Typical Installation
INSTALLATION INSTRUCTIONS
1. Select degree of opening from table and use template dimensions shown in above, mark six (6) holes on
door for door closer and two (2) holes on frame for arm shoe.
2. Drill pilot holes in door and frame for #14 all-purpose screws or drill and tap for 1/4-20 machine screws.
3. Install adjustable forearm/arm shoe assembly to frame using screws provided.
4. Install main arm to top pinion shaft using screws provided.
5. Mount closer on door using screws provided. SPRING POWER ADJUSTING NUT MUST BE POSITIONED
AWAY FROM HINGE EDGE.
6. Adjust length of adjustable forearm so that adjustable forearm is perpendicular to frame when assembled
to preloaded main arm (illustration below) Secure forearm to main arm with screw provided.
7. Snap pinion cap over shaft at bottom of closer. (When using full cover. pinion cap is not necessary)
8. Adjust closing speed, back check control and spring power of door, following instructions as shown page
4.
Left hand door shown
Right hand door opposite
Dimensions are in inches