The SARGENT Harmony Series H2 mortise lock is designed to interface with existing Wiegand Electronic
Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID
®
iCLASS
®
13.56MHz technology. Harmony Series technology is backed by SARGENT’s Grade 1 hardware.
The mortise lock comes with Request to Exit (RX) monitoring within the lock body and operates from
12-24VDC. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock position
(locked/unlocked). Gasket required for exterior door applications.
Latch: Stainless steel, 3⁄4” projection, one-piece
Deadbolt: One-piece hardened stainless steel
Guardbolt: Stainless steel, non-handed
Handed: Easily field reversible without opening case
Case: 12 gauge heavy duty wrought steel
Outside lever controlled by any 13.56MHz HID
iCLASS Wiegand credential
Field-selectable to Fail Safe or Fail Secure
General Description
2
Technical Specifications
3
Lock to be configured* as Fail Safe or
Fail Secure per AHJ compliance as part of
initial lock configuration
Locks furnished for 1-3/4” doors. Other door
thicknesses require confirmation with factory.
UL 294 Access Control Performance Ratings:
Destructive Attack Level I
Line Security Level I
Endurance Level IV
Standby Power Level I
ANSI/BHMA A156.25 Listed Grade 1 Compliant
UL and CUL listed for use on Fire Doors
This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
Regulatory Specifications
4
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
Door position switch within lock body
Inside lever provides RX signal and retracts
latch and deadbolt
• Reader Draw = 150mA @12VDC / 24VDC
• Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC
• Solenoid Draw = 250mA @12VDC
500mA @24VDC