User Manual

5
8
Installation Instructions
Installation of Inside Escutcheon (continued)
CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wire
damage and/or malfunction of the lock may occur.
1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide
onto spindle halfway. With inside escutcheon resting on spindle, be certain that all keypad ribbon
cable will remain inside ribbon cable hole, and that ground wire will not get pinched once
escutcheon is mounted. Escutcheon will not fit flush on door otherwise.
2. Insert 3 #10-24 screws through inside escutcheon and thread loosely into outside escutcheon. Check
operation of both inside and outside levers and make sure the turnpiece and key still operate the
latch and deadbolt correctly. If lock function is satisfactory, fully tighten the bottom two screws.
Check operation of both levers again. If levers move freely, tighten top screw. If levers do not move
freely, loosen bottom screws and realign the escutcheons until proper operation is obtained.
Inside
of door
Lockbody harness - Feed excess
wire back into the mortise of the
door between the door cavity and
lockbody. Do not feed excess
wires into the cylinder hole of
the lock.