6) ML20800 Hard Wiring Instructions
12
1.Caution: disconnect all input power before beginning installation to prevent
electrical shock and equipment damage.
2.Installer must be a trained, experienced service person.
3.All wiring must comply with applicable local electrical codes, ordinances
and regulations.
6.1) Important
1.With new applications, an ElectroLynx™ door harness with 8 and 4 pin connectors
will be pre-installed inside door by ASSA ABLOY door manufacturer when specified
during ordering process.
2.Wiring to pigtail harness is per facility wiring requirement. ElectroLynx™ connector
terminations and wire colors all match.
3.
If door does not have an ElectroLynx™ type door harness, cut connectors off
product and hard wire, or consult factory for appropriate mating harness.
6.2) Installation Notes
The system is designed to be installation friendly with pluggable connectors from the
electric hinge through the door to the rail. The only wiring required is to the loose wires
on the pigtail harness assembly on the frame side of the electric hinge.
IMPORTANT:
The plug and receptacle connectors are designed to mate and lock together as shown
in the figure. Plug the connectors into each other with the locking mechanism aligned
as indicated.
Do NOT Force connectors on any other way.
6.3) ElectroLynx™ Connector System Notes:
As part of their promise to provide
innovative, fast and effective, and higher
security solutions to their customers,
ASSA ABLOY Group companies offer
ElectroLynx™, a universal quick-connect
system that simplifies the electrification of
t
he door opening.
ElectroLynx™ is a registered trademark of
ASSA ABLOY North America, Inc.
Receptacle
Locking Mechanism
Plug
Hardwiring Made Easy
ELECTRO
TM