User Manual

6 1-800-810-WIRE • www.sargentlock.com • A8032D
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
12/15/10
Passport 1000 Series P1 PoE Mortise Lock
Order of installation may vary. Refer to appropriate sections for in-
structions.
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully fish the assembly through the
door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
4-pin male Molex connector
6-pin male Molex connector with ground wire
Lock-side harness connectors:
Ring terminal
(2) 4-pin connectors:
4-pin Molex connector
4-pin connector
Notes:
Connectors go on only one way. They cannot be plugged to
incorrect position.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
4-pin male Molex connector
6-pin male Molex connector with ground wire
Lock-side harness connectors:
Ring terminal
(2) 4-pin connectors:
4-pin Molex connector
4-pin connector
Notes:
Connectors go on only one way. They cannot be plugged to incorrect position.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
PoE Data Hinge
PoE Lock
JST
4-Pin
4-pin M 4-pin F4-pin F
4-Pin
Molex
6-pin F 6-pin F 6-pin M
Cable: CAT 5e,
26 AWG stranded,
shielded, 100ohm
Drain Wire
PoE Door Harness
C
D