User's Manual

12
IN100 Cylindrical Lock
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
e. Tuck excess cable into wire hole on inside of door.
f. Begin to secure the mounting assembly by partially tightening the (2) through-bolts on the
inside of the door while ensuring proper alignment as you secure the reader (Fig. 9b).
d. Feed the reader harness and DPS connectors through the inside mounting assembly
(and gasket if required*). See Figure 9b.
IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 9b, c) - it will damage wires and
the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9c).
5) Installation Instructions (Continued)
Fig. 9b
Gasket*
Mounting Plate
Lock body
Harness
Ground
Lug
DPS
Reader
Harness
NOTE: Cable lengths exaggerated for illustrative purposes.
Inside of Door
Through -
bolt
Through -
bolt
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors through holes
as indicated (Fig. 9b).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Fig. 9c
g. Secure ground lug with #6-32 machine screw (Fig. 9c).