User Manual

01/29/11
1-800-810-WIRE • www.sargentlock.com • A7786E 11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Profile Series v.S2 WiFi Mortise Lock
Step #7 – Inside Escutcheon Wire Connections
Images are shown without gasket. If gasket is necessary,
refer to Step #5.
Before the controller is attached to the door:
1. Attach the reader assembly
ribbon cable into the back of the
controller assembly (side that
faces towards the door when
mounted (Fig. 7A).
2. Attach the antenna to the
circuit board in the plastic
housing under the
controller assembly.
Note: The difference between
the wiring for the iCLASS 13.56
MHz reader and the 125 kHz
Prox is that the iCLASS wiring
includes an antenna wire.
3. Attach the ground wire
to the bottom of the
controller assembly (E1).
Step #8 – Lock Wire Connections
1. Connect the cable from the mortise lock
to the bottom of the controller assembly
(TB1, Fig. 8A).
2. Connect the AX/DPS connector to the
2-pin harness.
Mortise
Connector
Ground
Wire
Fig. 8A
Back
1
AX/DPS
2
Inside of Door
1
2
Outside
Escutcheon
Antenna
Unused
TB1
Reader
Ribbon Cable
Ground
Wire
Fig. 7A
3
1
2
Antenna
(iCLASS)
Outside
Escutcheon
1
2
3
Ground
Wire
Reader
Cable
Antenna
(iCLASS)
Reader
Ribbon Cable