User Manual

8/05/12
1-800-810-WIRE • www.sargentlock.com • A8122B 11
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock
10 Install Thumb Turn
Fig. 10
Thumb Turn
Inside of Door
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Orient mounting plate so screw hole is vertical (aligned with
preparation holes).
3. Secure plate with phillips screw provided.
4. Test thumb turn for function by retracting and projecting the deadbolt
(7976 and 7977 functions only).
Phillips
screw
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
11
Inside Mounting Plate Installation
1. Install washers onto both through bolts, Fig. 11A.
Insert the through bolts through the upper and lower
holes of the mounting plate.
2. Feed the DPS wire through the hole of the fire shield
and feed the lock wiring into the slot, Fig. 11B.
3. Place the fire shield against the door and place the mounting
plate over it so the through bolts align with the door holes.
Mounting Plate
Fire shield
Fig. 11C
Fig. 11A
Inside of Door
2x Through bolts
2x Through bolts
Fig. 11B
open slot
Scan this Microsoft® Tag using
your mobile phone to see a
video of this installation step.
The Microsoft Tag mobile app
is required to scan the Tag.
Download the free mobile app at
http://gettag.mobi
Preliminary