IN100 Mortise Lock
3
Lock Self Test LED Indication
After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated
using a series of red and green LED flashes as is described by the figure below:
Fig. Lock POST LED indication
The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the
status of each individual test as described by the following table:
Blink Meaning if Red Code in Event Log
2 Main board firmware corrupt 0x0001
3 Override list corrupt 0x0002
4 Production data corrupt 0x0004
5 Security data corrupt 0x0008
6 Configuration data corrupt 0x0010
7 Battery power low 0x0020
8 RFID reader circuit error 0x0040
9 Voltage regulator error 0x0080
10 Card detection circuit error 0x0100
11 Secure area communication error 0x0200
12 Secure area memory corrupt 0x0400
13 Secure area sensor or motor error 0x0800
14 Radio modem communication error 0x1000
15 Radio modem memory corrupt 0x2000
16 Radio modem configuration error 0x4000
17 Radio modem RF circuit error 0x8000
NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.
Instead, the 10 quick red flashes used to indicate Error in lock is shown.
One red, one green flash (1 second each)
One red flash followed by 16 red or green
flashes (.5 seconds each)
10 red flashes.
Good POST
Bad POST
The “Error in lock” indication is also
shown instead of the POST flashes
if the battery is not accepted as new
after a power-on-reset.