User Manual

8 1-800-810-WIRE • www.sargentlock.com • A8122B
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
8/050/12
IN100 Mortise Lock
4
Weather Conduit Installation (Optional P/N 52-2847)
Fig. 4A
Install weather conduit on NON FIRE-RATED metal exterior doors only (Fig. 4A).
1. Carefully insert the weather conduit into the ribbon cable hole
from the outside of the door.
2. Place the O-ring around the weather conduit on the inside and
up against the door (Fig. 4B).
Fig. 4B
O-Ring
Inside of Door
5 Install Lock body
1. Feed the wire harness through the mortise pocket
and inside preparation hole as depicted in Fig. 5.
2. Carefully push the lock body into the pocket while lightly
applying tension to the wire harness.
Note: Do not pull the lock into the pocket with the
harness alone. Ensure that the wire harness is not
pinched between the lock and the mortise pocket.
3. Insert (2) #12-24 screws into the lock body
and tighten with a screw driver.
Mortise
Connectors
Fig. 5
Inside of Door
(2) #12-24 screws
Scan this Microsoft® Tag using your mobile phone to
see a video of this installation step. The Microsoft Tag
mobile app is required to scan the Tag. Download the
free mobile app at http://gettag.mobi
Preliminary