User Manual

19
An ASSA ABLOY Group brand
P/N AYRT-220-INST-FUL Rev A
MISCELLANEOUS
Cycle the lock in both the locked and the unlocked positions. If problems are found:
TROUBLESHOOTING
Hardware Troubleshooting
Symptom Suggested Action
Door is binding a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Latch will not deadlock a. Check for sufficient clearance of the latch within the strike-side jamb. Correct this by
increasing the depth of the pocket for the latch.
b. Check for misalignment of latch and/or strike which may be preventing latch from
properly entering the strike. With the door open, extend and retract the latch; if it is
smooth, check the strike alignment.
Latch does not extend or retract smoothly a. Latch and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to latch.
c. Verify proper door preparation and re-bore holes that are too small or misaligned.
d. Verify keypad cable/connector is routed under the latch (see Fig. A).
e. Verify latch is installed with correct side up (Fig. A).
Inside of Door
Figure A
Hardware Troubleshooting ......................................................................................17
Programming Troubleshooting ...............................................................................18
Installing the Network Module ...............................................................................19
Change Lever Handing .................................................................................... 20-21
Replace/Install Cylinder .........................................................................................22
Sample Pin Code Management Sheets ........................................................... 23-24