7.11 RUNTIME
The light is able to adjust its power to meet a certain runtime on
battery. The runtime is always calculated for a full battery.
Example:
If the light is required to light during an eight hour event,
and one hour of setup time is scheduled, then the
runtime should be set to nine hours immediately after the
first power up.
Please note, that the light should not be stored below 20°C
before an event, otherwise the runtime might be shorter than
calculated.
More details on the built in battery can be found at chapter 0.
7.12 ANTI-FLICKER
The PWM refresh rate of this light is 599.4 Hz by default. This frequency can be freely adjusted
between 200 Hz and 1205 Hz to fit different camera’s frame rates.
Make sure you have
targeted the lights you wish
to adjust (chapter 7.5).
Then press the “Anti-Flicker”.
Slide the “fps” to adjust to
default values for a
framerate.
Slide the “Hz” to fine-adjust.
Press the highlighted
frequency to enter a custom
value between 200 and
1205 Hz.
NOTE:
The Anti-Flicker adjustment is preserved in case the lamp is powered off.
It is set back to the default 599.4Hz once a Reset Settings (chapter 6.21) is done.
The adjusted frequency is used no matter what input source is currently active. Also during