INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS E Series Salt Chlorinator ND ModelsBolero M20 CSD and M25 CSDCleaner Part numbers 10814 and 10815 INSTALLATION AND OPERATING INSTRUCTIONS Melbourne: 03 8796 8600 Sydney: 02 9853 2100 Brisbane: 07 3308 5400 27/05/2010 Gold Coast: 07 5552 2600 Townsville: 07 4750 3100 Adelaide: 08 8152 7600 Perth: 08 9350 2600 sales@astralpool.com.au www.astralpool.com.
INDEX 1.0 Introduction…………………………………………………………………………………………………. 3 2.0 Installation…………………………………………………………………………………………………... 3 2.1 Mounting the Controller……………………………………………………………………… 4 2.2 Connecting the PVC Acid Tube……………………………………………………………….. 4 …………………………………………………………………………………………………….. 5 3.0 Starting your Chlorinator……………………………………………………………………………………. 6 3.1 Set Up………………………………………………………………………….…………………………….. 6 3.2 Setting Timers………………………………………………………………………………………………... 6 3.
Warning: The appliance is not intended for use by young children or infirm persons without supervision. Please ensure that young children are supervised to ensure that they do not play with the appliance. Controller must be installed according to AS 3000 wiring rules. If the supply cord is damaged it must be replaced by Astral Pool or its service agent or a similar qualified person in order to avoid a hazard. 1.0 INTRODUCTION Congratulations on your purchase of the E Series M20 or M25 CSD salt Chlorinator.
g. Remove cap from pH sensor and screw firmly 50mm T installed in the plumbing. Do Not Overtighten. h. The water connections to the Cell are 50mm high pressure PVC pipe. Glue into Union tails using PVC glue as show above. Direction of flow through the cell is not critical. WARNING: Never install the cell before the pump or heater i. The cell must be installed with the barrel unions underneath and the cell should be horizontal. Both 40mm and 50mm fittings have been provided.
2.2 CONNECTING THE PVC ACID TUBE Before installing the unit in position on the wall or post, the length of the PVC tubing provided should be measured and taken into consideration. Ensure the Controller and Cell are close enough for the power supply lead to reach the cell and sufficient PVC tube exists to connect Acid Container and Cell. To avoid loss of water from the system, close all stop valves before cutting any lines.
3.0 STARTING YOUR CHLORINATOR Your Chlorinator Controller operation can be divided into 4 areas; a. MAINTENANCE – selects specialised functions of your chlorinator and initial set up of Chlorinator to suit your pool and spa. b. SET – selects changes in Chlorine Product and pH of your pool and spa water c. CLOCK & TIMER buttons – sets current time and filtration, chlorine production and pH monitoring and adjustment times from Monday to Friday and Weekends d.
3.3 TIMER RECOMMENDATIONS: Hurlcon recommend that you use two timers, one for the morning and one for the evening and typically for periods of 2-5 hours for each. Your E Series CSD Chlorinator is most effective if running in the early morning or evening when it is cooler (strong sunlight consumes more chlorine). As a default, the control is set to come on at 08:00 hours and 16:00 hours both for periods of 4 hours. Timer Clock WEDNESDAY 11:07 POOL SANITISING OFF UNIT 16:00 SET MAINT 4.
b. SET SPA WATER VOLUME, select YES if your have a SPA attached to your pool and then set volume. Press ACCEPT c. ENABLE ALARM? Select YES and an alarm will sound if you run our of ACID or the ACID adjustment is not working. d. SELECT the Maximum pH value to trigger the alarm. It is recommended this is set at 8.0. e. SELECT the Minimum pH value to trigger the alarm. It is recommended this is set at 6.8. f. DOSE CYCLE 240 Seconds. In normal circumstances this will suffice for most pools – press ACCEPT. g.
6.0 OPERATION During operation, adjustments are made by the SET button. Timer Clock WEDNESDAY 16:05 POOL SANITISING ON UNIT 20:00 SET MAINT 6.1 ADJUSTING CHLORINE OUTPUT Press the SET button to change the chlorine output and the pH of your Pool CHANGE CHLORINE SET POINT Timer Clock YES NO Press YES to change the output Timer SET POINT 6 Clock ACCEPT Use the up and down buttons to change the Set Point between 0 and 8. 0 chlorine output should only be used when there is no salt in the water.
6.2 ADJUSTING PH SET POINT Continue through the SET menu to change the pH balance of your pool. As a guide the pH in your pool should be set between 7.2 and 7.8. This will be determined by the type of pool you have, (Concrete, Fibreglass, Vinyl Liner) and you should rely on your pool builder or pool professional to recommend the correct pH Set Point. Use the up and down arrows to set your pH value.
7.5 Salt Level Salt level should be maintained around 4,000ppm but should never be allowed to fall below 3,000ppm. Although salt is not consumed by the Chlorinator, salt is lost during backwashing, and when your pool overflows due to rain or splashing. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set-up the pool to 4,000ppm.
7.8 Manual Cell Cleaning Create a mild acid solution, of 1 part hydrochloric acid to 5 parts water in a bucket of water. Always add Acid to the water. To clean cell – turn power to chlorinator off to prevent pump operating. Close isolation valves if chlorinator cell is installed below water level. Supply leads, sensor lead and PVC tube may require removal from the Cell. Unscrew the lock ring in an anti clockwise direction. Remove electrode from assembly from the cell housing.
9.0 Fault Indication and trouble shooting Fault Indication No Flow Low salt Display blank Low/No chlorine production Potential Cause Pump turned off/disconnected or valves closed Remedy Ensure valves/pump on Sense wire disconnected from cell Connect sense wire to cell Salt level in pool has dropped too low See section 7.5 above Pool water temperature is low Cell has calcified Increase salt level or raise water temperature See section 7.
10.0 WARRANTY Your E Series CSD Chlorinator is covered by a limited 5 year warranty. The Electrolytic Cell is covered by a full 5 years warranty against defects in materials and assembly from the date of purchase plus 30 days to allow for installation. The Controller is covered by a 2 year warranty from the date of purchase plus 30 days to allow for installation.
E- Series Chlorinator M20 CSD & M25 CSD V05_10 15
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS ASTRALPOOL Pty. Limited. A.B.N. 97 007 284 504 www.astralpool.com.au email: service@astralpool.com.au Information and specifications subject to change without notice.