Operating instructions
E- Series Chlorinator M20 CSD & M25 CSD V05_10
8
b. SET SPA WATER VOLUME, select YES if your have a SPA attached to your pool and then set volume.
Press ACCEPT
c. ENABLE ALARM? Select YES and an alarm will sound if you run our of ACID or the ACID adjustment is
not working.
d. SELECT the Maximum pH value to trigger the alarm. It is recommended this is set at 8.0.
e. SELECT the Minimum pH value to trigger the alarm. It is recommended this is set at 6.8.
f. DOSE CYCLE 240 Seconds. In normal circumstances this will suffice for most pools – press ACCEPT.
g. ADJUST CELL CLEAN FREQUENCY – Most pools require medium level of cell clean frequency, press
ACCEPT.
h. ADJUST CELL CLEAN DURATION – Most pools require a medium duration cell clean, press ACCEPT.
i. TIMER ENABLED – this function will turn your timer on or off. If the chlorinator is not connected to an
external timer clock or Genus Remote Control system Press ACCEPT. If an external timeclock is used to
operate the chlorinator and filter pump then change to disabled.
j. FLUSH AFTER TIMER. This function will turn the filtration pump on 15 minutes after the time period is
finished to ensure the pH probe is not affected by ACID during the timer OFF period. Press ACCEPT
k. RESET SYSTEM? If you are happy with your settings press ACCEPT.
i. The unit will now reset itself with your individual settings to suit your pool.
ii. Cycle through POOL MODE button to select Auto, Manually ON or Manually OFF.
a. AUTO will allow the unit to operate your filter pump, chlorine production and pH adjustment on the timer
periods you have selected. If you have not changed the timer periods, the default timer turns the filter
pump and unit on at 08:00 hours for a period of 4 hours and then again at 16:00 hours for a further period
of 4 hours. This is the default setting from the factory.
5.0 CALIBRATION OF PH SENSOR/PROBE:
From time to time, the pH sensor will require cleaning and calibration. Typically, calibration should take place one
every 6 to 12 months.
To Calibrate, Press MAINT and next until CAL appears on the LCD. Select CAL to commence the process.
CAL
The pH probes/sensor has been factory calibrated. However it is a good practice to check the adjustment for the
probe periodically (say 6 months or earlier if required). The probe should be cleaned first (refer under Maintenance
page 13 for cleaning) and allowed to settle down for about 4-5 minutes before adjusting/calibrating. Calibration
solution is available via AstralPool as a spare part.
pH When the controller is in Manual Off mode, remove the pH probe from the pipe line (shut off the filter pump and
close any isolation valves to avoid water spill), clean the probe (see under Maintenance) and place it in a 7.5 pH
Easy cal Solution (available from AstralPool). Press MAINT and then next until CAL is displayed. The unit will ask
CHANGE PH CALIBRATION, select YES. Select NO to Filter Pump on?
The display will indicate that the system is measuring pH. When the pH is displayed, press the UP or DOWN
buttons to get the display to indicate the same value as the buffer (7.5) and then press ACCEPT
MAINTENANCE MODE
SELECT FUNCTION?
EXIT CAL NEXT