INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS AstralPool Pumps CTX Series, E Series Bolero ND BX Series & FX Series Cleaner INSTALLATION AND OPERATING INSTRUCTIONS Melbourne: 03 8796 8600 Sydney: 02 9853 2100 Brisbane: 07 3308 5400 19/03/2014 Gold Coast: 07 5552 2600 Townsville: 07 4750 3100 Adelaide: 08 8152 7600 Perth: 08 9350 2600 sales@astralpool.com.au www.astralpool.com.
Inst243 AstralPool Pump Instructions V05.
GENERAL A high performance, high head pump ideally suited for the modern pool or spa with extensive equipment such as chlorinators, heaters and in floor cleaning. Note: The appliance is not intended for use by young children or infirm person without supervision. Please ensure that young children are supervised to ensure that they do not play with the appliance.
INSTALLATION OF BX, CTX & E SERIES PUMPS A. Plan position of pump so that it will be: 1. 2. Free of water flooding, such as in a sump, garden hollow, ditch or at the bottom of a bank. On a stable base so that: a) The pump is not left suspended by its fittings, causing a leak or failure with loss of water. b) Movement through vibration is restricted c) No strain is put on attaching pipe or other expensive equipment 3. Accessible for maintenance and easily removed for service. 4. Breathing space.
INSTALLATION OF FX SERIES PUMPS A. Plan position of pump so that it will be: 1. Below the pool or spa water level unless pump is primed to be a secondary pump, 2. Free of water flooding, such as in sump, garden hollow, ditch or at bottom of bank with run off. 3. On a stable base so that: a) The pump is not left suspended by its fittings, causing a leak or failure with loss of water. b) Movement through vibration is restricted. c) No strain is put on attaching pipe or other expensive equipment. 4.
3 PHASE PUMP INSTALLATION To be performed only by a qualified electrician. 1. 2. 3. 4. 5. Connect power to motor Ensure that pump is empty of all water Momentarily apply power to motor and check rotation direction of motor matches that of the arrow located on the rear of the pump seal plate. If motor is rotating in the opposite direction to arrow on pump, correct phase wiring. Once rotation is correct, fill pump with water, prime as described below and test pump operation.
OPERATION OF FX SERIES PUMP 1. Open all valves, allowing fluid to flow through pump. 2. If an air lock occurs and no water appears to fill pump housing once the valves have been opened, release outlet barrel union slowly until a small amount of water escapes from the pump then re-tighten. 3. Switch on power to pump, motor to start. 4. If some flow of water does not establish within on half minute, switch off and repeat procedure 3 again.
Maintenance of your pump Maintenance Schedule: You new product incorporates moving parts and withstands high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/replacement before further serious damage is sustained.
Electrical Specifications All Astral Pool pumps have double insulation on the water circuit for maximum protection and safety. Pumps manufactured by Astral Pool use P2 rated capacitors for protection against fire. Inst243 AstralPool Pump Instructions V05.
WARRANTY AstralPool Australia Pty Ltd (ABN 97 007 284 504) ("AstralPool") provides the following warranty in relation to its series of Pool & Spa pumps ("Product"). Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
Exclusions The warranty will not apply where: (a) the customer is in breach of the Terms and Conditions of Sale; (b) the Product was used for a purpose other than one it was intended for; (c) the Product was repaired, modified or altered by any person other than AstralPool; (d) the Product has not been installed, maintained and/or operated in complete compliance with the installation and operating instructions and any instructions by AstralPool; (e) the Product has been subject to accident, negligence, alte
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS ASTRALPOOL Pty. Limited. A.B.N. 97 007 284 504 www.astralpool.com.au email: service@astralpool.com.au Information and specifications subject to change without notice. Victoria: Ph: (03) 8796 8600 Fax: (03) 8796 8670 New South Wales: Ph: (02) 9853 2100 Fax: (02) 98532170 Queensland: Ph: (07) 3308 5400 Fax: (07) 3308 5470 Inst243 AstralPool Pump Instructions V05.