Operating instructions
Inst.241a Viron Series Pool & Spa Heater V08.11
10
The flue temperature will be approximately 85 degrees C and should be kept at least 25 mm clear of any
combustible surface.
4/ Joining flue sections.
Supplied with the flue is a special joiner piece. To join the flues insert a bead of silicon into both ends of the joiner .
Push the flue into the end of the joiner piece. Secure the flue with pop rivets. Repeat for the second flue pipe
connection.
5/ Rooftop terminations.
All flue exiting the roof must be shielded with the gal cover. Extra lengths of gal can be supplied. Decktite fittings
/ flashings must be attached to the galvanised flue cover. Brace flue in high wind applications.
Locate flue cowl onto reduced end of the gal outer covering / flue pipe. Attach with rivets / screws to hold into
place.