User Manual

Table Of Contents
WARNING
To avoid possible electric shock or personal injury, and to
avoid possible damage to the Meter or to the equipment being
tested, adhere to the following rules:
When servicing the Meter, use only the same model number
or identical electrical specifications replacement parts.
● When using the test leads, keep your fingers behind the
finger guards.
● Do not apply more than the rated voltage, as marked on the
Meter, between the terminals or between any terminal and
grounding.
● Do not use or store the Meter in a high-temperature
environment, do not expose to high levels of humidity, or
near strong magnetic fields. The performance of the Meter
may deteriorate after dampening.
● When the Meter is working at an effective voltage over 60V
in DC or 30V rms in AC, special care should be taken
because there is a danger of electric shock.
● When measuring, connect the neutral wire or ground wire
first, and then connect the live wire; when disconnecting,
disconnect the live wire first, and then disconnect the neutral
wire and the ground wire.
● Replace the battery as soon as the battery indicator
appears. With a low battery, the Meter might produce false
readings that can lead to electric shock and personal injury.
● Remove the connection between the testing leads and the
circuit being tested and turn the Meter power off before
opening the Meter case.
● The manual rotary switch should be placed in the correct
position before measurement and should NOT be moved
during measurement to prevent damage to the Meter.
● Turn the Meter off when not in use and take out the battery
when it is not going to be used for an extended period.
Regularly check the battery as it may leak when it has not
been used for some time. Replace the battery as soon as
leaking appears. A leaking battery will damage the Meter.
ELECTRICAL SYMBOLS
MULTIMETER DIAGRAM
-3- -5-
100*140mm
-4-
Test Leads
11
K-Type Thermocouple
12
11
12
-6-
BUTTONS FUNCTIONS
Backlight: Press this button to turn on/off the
screen’s backlight.
Flashlight: Long Press this button to turn on/off the
flashlight.
When taking a measurement, press this button once
to enter “Max Mode. In this mode, the multimeter
will capture the highest reading it records. Press this
button again to enter “Min Mode” which will capture
the lowest reading it records. Press and hold this
button to exit the Max/Min Modes.
Button Function
Use the rotary switch to select a function. Use the
FUNC Button to further select the function if there
are multiple functions in one rotary setting.For
example: Switching between AC and DC voltage
tests.
NOTE: Pay special attention to the selected setting
before performing any tests.
Press this button while performing a test to hold
(freeze) the reading for easy recording. The screen
will display when the hold function is activated.
Press the button again to cancel the data hold.
H
SETTING FUNCTION
-7-
● TERMINALS
-8- -9-
● OTHER FUNCTIONS
Auto Shut Off:
After 15 of standby, the Meter will automatically turn off. To
turn it on again, just rotate the range switch or press a
button.
V
V
Turn the rotary dial to the setting. When the
voltage is below 600mV, turn the dial to the
setting. Press the “FUNC” button to switch
between AC/DC voltage. The screen will
indicate the setting that the DMM is currently
in. “DC” will display for DC measurements
and “AC” will display when the Meter is set to
measure AC.
V
mV
HOW TO USE THIS MULTIMETER
Ⅰ. MEASURING VOLTAGE
Insert the red test lead into the “Input” jack
and the black test lead into the “COM” jack.
After the reading stabilizes, record the reading from the LCD
screen.
● Turn the rotary switch to the OFF position to turn off the
Meter.
VOLTAGE NOTES:
● To avoid damage to the meter, do not measure voltage
exceeding 600V DC or 600V AC
● Pay special attention to the voltage setting of the Multimeter.
The LCD screen will indicate whether the setting is in AC.
Use the “FUNC” button to choose the appropriate setting.
● SPECIAL NOTE: The orange backlight will illuminate when
the measured voltage is higher than 80V.
-10-
. MEASURING CURRENT
● Turn the rotary dial to the , , or setting
according to the current level to be measured.
A
Hz
mA
HzHz
μA
● When the screen displays “DC” the Meter
is in the DC function, when “AC” is
displayed, the Meter is in the AC function.
● Under the and settings, connect the red
test lead to the input terminal and the black
test lead to COM terminal.
mA
HzHz
μA
Disconnect the power supply of the circuit under test.
Connect the meter to the circuit under test in series, and
then turn on the power supply of the circuit.
Under the setting, connect the red test
lead to 10A terminal and the black test
lead to COM terminal.
A
Hz
● The reading will be displayed on the LCD screen.
● Insert the red test lead into the “Input” jack
and the black test lead into the “COM” jack.
Ⅲ. MEASURING FREQUENCY/DUTY CYCLE
● Turn the rotary dial to the setting.
Hz%
● The reading will be displayed on the LCD screen.
. MEASURING RESISTANCE
● Turn the rotary dial to the setting.
Ω
● Insert the red test lead into the “Input” jack
and the black test lead into the “COM” jack.
● The results will appear on the LCD display.
● Place the test leads at both ends of the resistance to be
measured and maintain strong contact.
RESISTANCE NOTES:
● Do not change the resistance while taking a measurement.
Doing so may damage the Meter and affect the test results.
● Do not directly measure the internal resistance of micrometers,
galvanometers, batteries, and other instruments.
● Do not test parallel circuits. The accuracy of the
measurement will be affected, and the results may not be
accurate.
● If the measured value is equal to the nominal resistance of
the resistor or within the range of error, the resistor is
functioning correctly.
● If there is a large deviation between the nominal resistance
and the measured resistance, the resistor is bad.
● If the measured resistance is infinite (open circuit), zero
(short circuit), or unstable, it means the resistor is damaged
and can no longer be used.
-11- -12-
. MEASURING CAPACITANCE
Turn the rotary dial to the
setting. Press the “FUNC” button
to switch to Capacity Test.
Ω
Insert the red test lead into the “Input” jack
and the black test lead into the “COM” jack.
● Make a secure connection between the test leads and both
ends of the capacitor.
Insert the red test lead into the “Input” jack
and the black test lead into the “COM” jack.
. CONTINUITY TEST
● Turn the rotary dial to the setting.
● Place the test leads on both sides of the object to be
measured.
. DIODE TEST
Set the function switch to “ ” range,
Press the “FUNC” button to switch to
diode Test.
Connect the black test lead to the “COM” jack
and the red test lead to the “INPUT” jack.
● Connect the red test lead to the positive end of the diode
and the black test lead to the negative end.
NOTE: Generally, the positive end of the diode is the longer
end.
● The LCD will show the reading of the voltage decreased by
the diode. If the leads are incorrectly connected to the diode
electrodes, the LCD will show “OL”.
. TEMPERATURE MEASUREMENT
● Set the function switch to “ ” range.
℃/℉
● Insert the negative (-) plug of the K-type
thermocouple to the COM jack and the
positive (+) plug to the INPUT jack.
● Carefully touch the end of the thermocouple to the object
being measured.
● Celsius and Fahrenheit are both displayed.
NOTE: Results take time to stabilize as thermal equilibrium is
reached with the measuring environment. When the
thermocouple is not in contact with an object being measured,
it will read the ambient temperature of the surrounding
environment.
. NON-CONTACT VOLTAGE (NCV)
The NCV function detects AC voltage without
the use of test leads.
NCV
Live
● Set the Rotary Dial to the NCV function .
● When the meter senses a weak AC signal, the green
indicator light will turn on and the buzzer emits a slow beep;
When the meter senses a strong AC signal, the red indicator
light will turn on, and the buzzer will emit a quick beep.
NOTE: This function does not affect the Meter’s
measurement after exiting the setting. If the range switch is
not in the NCV position, the Meter will operate normally.
. LIVE WIRE DETECTION
● Turn the rotary dial to the setting.
Press the “FUNC” button to switch to
Live Wire Detection and the screen
will show “Live”.
NCV
Live
Insert the red test lead into the “Input”
jack. Do not insert the black test lead into
any terminal.
● When the meter senses a weak AC signal, the green
indicator light will turn on, and the buzzer emits a slow beep;
When the meter senses a strong AC signal, the red indicator
light will turn on, and the buzzer will emit a quick beep.
-16--13- -14- -15-
TROUBLESHOOTING
The reading
does not
stabilize
● Check the test leads for damage.
● Check the contact between test leads and
object being measured.
● Check the connection between the test
leads and the Meter.
Reading is
not accurate
● Check the test leads for damage.
● Check if the battery needs to be replaced.
A certain
range is not
available
Adjust the contact point of the transfer
switch.
Range error
is large
● The variable value of shunt resistance
needs to be adjusted or replaced.
No reading
● Check whether the fuse is intact.
● Check the test leads for damage.
Range
600mV
Resolution Accuracy
0.1mV
6V
0.001V
60V
0.01V
±(0.5% rdg +3 dgts)
600V
0.1V
1000V
1V
● Input Impedance : 10MΩ
● Overload Protection : 1000V DC/750V AC
● Input Impedance: 10MΩ
● Overload Protection: 1000V DC/750V AC
● Frequency Range: 40Hz ~ 1kHz
● Response: True RMS
DC CURRENT
600μA 0.1μA
6000μA 1μA
60mA 0.01mA
Range
Resolution
Accuracy
±(1.2% rdg +3 dgts)
600mA 0.1mA
10A 0.01A
● Overload Protection: “A/mA”: F600mA/250V fuse
“10A”: F10A/250V fuse
● Max.Input Current: “A/mA” jack: 600mA
“10A” jack: 10A
(For measurements>5A: duration <10 seconds, interval >15
minutes)
AC CURRENT
600μA 0.1μA
6000μA
1μA
60mA 0.01mA
±(1.5% rdg +3 dgts)
600mA 0.1mA
10A 0.01A
Range
Resolution
Accuracy
● Overload Protection: “A/mA”: F600mA/250V fuse
“10A”: F10A/250V fuse
● Max.Input Current: “A/mA” jack: 600mA
“10A” jack: 10A
● Frequency Range: 40Hz ~ 1KHZ
● Response: True RMS
(For measurements>5A: duration <10 seconds, interval >15
minutes)
RESISTANCE
Overload Protection: 250V
600Ω 0.1Ω
6kΩ 0.001kΩ
60kΩ 0.01kΩ
±(1.0% rdg +3 dgts)
600kΩ 0.1kΩ
6MΩ 0.001MΩ
60MΩ 0.01MΩ
±(1.5% rdg +3 dgts)
Range
Resolution
Accuracy
TEMPERATURE
CAPACITANCE
Overload Protection: 250V
10nF 0.001nF
100nF 0.01nF
1000nF 0.1nF
±(4.0% rdg +5 dgts)
10μF 0.001μF
100μF 0.01μF
1000μF 0.1μF
10mF 0.001mF
100mF 0.01mF
±(5.0% rdg +5 dgts)
Range
Resolution
Accuracy
FREQUENCY/DUTY CYCLE
NOTE:
and , Frequency measurement:
● Measuring range: 0 ~ 10kHz
● Voltage range: 0.5~600V AC (the higher the measured
frequency, the higher the voltage should be)
● Overload Protection: 250 V
V
Hz
mV
Hz
 , ,and Frequency measurement:
● Measuring range: 0 ~ 10 kHz
● Signal range; ≥ 1/4 range (the higher the measured
frequency, the higher the current should be)
● Overload Protection: “A/mA”F600mA/250V fuse
“10A” F10A/250V fuse
A
Hz
mA
HzHz
μA
DC VOLTAGE
DIODE AND CONTINUITY
Range
Introduction
The approximate forward
voltage Drop will be
displayed.
Test voltage: 3.0V
Overload
Protection250V
Remark
If the value of the measured
resistance or circuit is less than
30Ω, the buzzer will emit a beep and
the green indicator light will
illuminate. When the value is
between 30Ω~60Ω, the red indicator
light will illuminate, and the screen
will display the measured value.If
there is no continuity, the buzzer will
not sound, “OL” will appear on the
screen, indicating infinite resistance.
Test voltage:
1V
Overload
Protection:
250V
MAINTENANCE
CLEANING THE METER:
If there is dust or humidity in the terminals, it may produce
erroneous measurements. Please clean the Meter as follows:
● Turn of the power to the Meter and remove the test leads.
● Wipe the case with a damp cloth or mild detergent. Do not
use abrasives or solvents. Wipe the contacts in each
terminal with a clean cotton swab dampened in alcohol.
REPLACING THE BATTERY AND FUSE
BATTERY REPLACEMENT:
● Turn off the Meter and remove the test leads.
● Remove the screws on the battery cover with a screwdriver,
and remove the cover.
● Remove the old battery and replace it with a new battery of
the same specification. Please pay attention to the polarity
of the battery. The positive and negative polarity of each
battery is marked in the battery box.
● Put the battery cover back to its original position and fix the
battery cover with the removed screws.
REPLACING FUSES:
Fuses rarely need to be replaced and are usually blown due
to operator error. To replace the fuses:
● Disconnect the test leads.
● Remove the rubber sleeve and screws on the back cover of
the Meter.
● Open the back of the Meter and replace with fuses of the
same rating.
It is crucial that the replacement fuses have the same
rating:
Fuse 1: F600mA/250V fuse,6mmX32mm
Fuse 2: F10A/250V fuse,6mmX32mm
INCLUDED IN BOX
● 1 x Owner’s Manual
● 1 x Pair of Test Leads
● 1 x K-Type Thermocouple
● 1 x AstroAI 6000 Counts Multimeter
Web:.astroai.com
E-mail:support@astroai.com
3 YEAR WARRANTY LIMITED WARRANTY FROM ASTROAI
Each AstroAI Digital Multimeter will be free from defects in
material and workmanship. This warranty does not cover
fuses, disposable batteries and damage from neglect,
misuse, contamination, alteration, accident, or abnormal
conditions of operation or handling, including overvoltage
failures caused by use outside the Multimeter’s specified
rating, or normal wear and tear of mechanical components.
This warranty covers the original purchaser only and is not
transferable.
If this product is defective, please contact AstroAI Customer
Support at support@astroai.com.
V1.0
FUNC
HOLD
MAX/MIN
M6KOR
MAX
10A
TRUE RMS
MAX
MAX
750V
10A/250V
600mA/250V
1000V
600V
CAT III
CAT IV
1000V
COM
μA
mA
VΩHzLive℃/℉
OFF
V
mV
A
mA
NCV
Live
Ω
Hz
Hz
Hz
Hz
Hz
Hz %
℃/℉
μA
AstroAI
6000
Counts
AC
DC
H
MkΩHznμmAVF°C°F
MAX MIN
Live
°F°C
kHz%
10 20 30 40 50 600
Category IV test equipment is suitable for testing
and measurements of circuits connected to the
power supply of a low-voltage power supply unit in a
building.
CATIV
Dangerous VoltageWarning
Earth Ground
DC (Direct Current)
Fuse
AC and DC
Double Insulation
Low Battery Symbol
Category III test equipment is suitable for testing
and measurements of circuits connected to the
power distribution portion of a low-voltage power
supply unit in a building.
CATⅢ
AC
(Alternating Current)
Compliance with
EU Standards
AC/DC Current Test : 0~10A
A
Setting
Function
DC Voltage Test : 0~1000v
AC Voltage Test : 0~750v
AC/DC Voltage Test: 0~600mv
Resistance Test : 0.1Ω~60MΩ
NOTE: Use the FUNC Button to further select the function
if there are multiple functions in one rotary setting.
V
mV
Ω
Capacitance Test : 0.001nF~100mF
Audible Continuity Test
Diode Test
Frequency
Duty Cycle
Hz
%
mA
AC/DC Current Test : 0~600mA
μA
AC/DC Current Test : 0~6000uA
Fahrenheit Temperature
Celsius Temperature
NCV Detection
Live Wire Detection
NCV
Live
10Hz 0.001Hz
100Hz 0.01Hz
1000Hz 0.1Hz
±(1.0% rdg +3 dgts)
Range
Resolution
Accuracy
-17- -18- -19- -20- -21-
● The accuracy does not include the error of the thermocouple
probe.
-4~ 32
32~ 752
752~ 1832
±5.0% rdg or±6
±1.0% rdg or±4
±2.0% rdg
1
-20~ 0
0 ~ 400
400 ~ 1000
±5.0% rdg or±3
±1.0% rdg or±2
±2.0% rdg
1
Range
Resolution
Accuracy
-22- -23-
True RMS 6000 Count
Digital Multimeter
Input Indication:
When turning on or function switching, the corresponding
input indicator light will flash to remind the user which
terminal is inserted.
AC Frequency Display:
When measuring AC voltage/current, the frequency of the
voltage/current will display.
High Voltage/High Current Indication:
When the measured voltage is higher than 80V or the
measured current is higher than 1A, the orange backlight will
light up, prompting the user to be careful.
Low Battery Indication:
If the“ ” symbol appears on the display, the battery should
be replaced immediately.
Thank you for purchasing the True RMS 6000 Count Digital
Multimeter from AstroAI. The AstroAI True RMS Digital
Multimeter is designed to be safely and accurately used by
professionals or DIYer’s that need a little more utility from their
standard digital multimeter. This manual provides all safety
information, operation instruction, specifications, and
maintenance for the meter. The instrument performs AC/DC
Voltage, AC/DC Current, Resistance, Audible Continuity,
Diode, Frequency, Duty Ratio, Capacitance, NCV Detection,
Live Wire Detection and Temperature Testing. Thank you
again for choosing AstroAI, if you have any questions or
concerns regarding your product, please contact us at
support@astroai.com.
NOTE: Fully read and understand this manual before using
this Digital Multimeter.
Before using the Meter, inspect the exterior casing. Do not
use the Meter if it is damaged or if all or part of the exterior
casing is removed. Look for cracks or missing plastic. Pay
special attention to the insulation around the connectors.
Comply with local and national safety regulations. Wear
personal protective equipment (such as approved rubber
gloves, masks, and flame-retardant clothing, etc.) to prevent
injury from electric shocks and arcs when hazardous live
conductors are exposed.
Check whether the Meter is working normally by measuring
the known voltage, do not use if the readings are incorrect or
the Meter is damaged.
1
2
3
4
1
Plug the red test lead into this terminal for
currents between 600mA and 10A.
2
Plug the black test lead into this terminal.
Plug the red test lead into this terminal for
currents less than 600mA.
4
Plug the red test lead into this terminal for all
measurements except current.
3
● Connect the test leads to the source of load to be measured.
Neutral wire first, then live wire.
● Measurement results will be displayed on the LCD display.
1
3
4
5
6
7
9
8
10
2
GETTING TO KNOW YOUR DEVICE
● Connect the test leads to the source or load to be measured.
● Touch the point to be measured with the tip of the red test
lead.
GENERAL TECHNICAL INDICATORS
Operating
Environment
● CAT. IV 600V; CAT. III 1000V
● Pollution Degree: 2
Altitude: <2000m (6562ft)
● Operating Temp: 32~104°F (0~40°C)
● Operating Humidity: (<80% RH)
● Temperature Coefficient: 0.1 x accuracy/°C
(<18°C or >28°C)
Storage
Environment
● Storage Temperature: 14~140°F (-10~60°C)
● Storage Humidity: (<70% RH, take out
battery)
AC VOLTAGE
60V
0.01V
±(0.8% rdg +5 dgts)
600V
0.1V
750V
1V
Range
600mV
Resolution
Accuracy
0.1mV
6V
0.001V
10MHz 0.001MHz
1~99% 0.1%
±(3.0% rdg +3 dgts)
Measuring range: 0~ 10MHz
Voltage range: 0.2~10V AC (the higher the measured
frequency, the higher the voltage should be)
Overload Protection250V
±(1.0% rdg +3 dgts)
10kHz 0.001kHz
100kHz 0.01kHz
1000kHz 0.1kHz
-2-
Maximum
Voltage
● DC1000V/AC750V
Fuse
Protection
● mA : F600mA/250V fuse,6mmX32mm
● 10A: F10A/250V fuse,6mmX32mm
Sampling
Speed
● 3x per second
Display
● 6000 counts display. Automatically displays
unit according to rotary dial.
Overload
Indication
● “OL” Displayed
Low Battery
Indication
● displayed when battery voltage is lower
than normal.
Polarity
Indication
● “-”Automatically displayed
Power
● 2 x 1.5V AA Batteries
3
Indicator Light
NCV Detector
1
Flashlight Button
2
LCD Screen
4
Function buttons
5
Rotary Function Switch
6
10A Terminal
7
INPUT Terminal
8
μA/mA Terminal
10
COM Terminal
9

Summary of content (1 pages)