NOTE: The LCD transmitter will also have the 
zone 2 icon and the alarm icon indicating. 
4.  The in vehicle LED will illuminate continuously for the duration of shock adjustment 
mode. 
NOTE: When the shock sensor adjustment mode is 
entered, all other timers and operations are bypassed 
until shock sensor adjustment mode is exited. 
ADJUSTING THE SHOCK SENSOR SETTING 
NOTE: When adjusting the shock sensor, 
ensure that the vehicle’s doors are closed. 
1.  Increase Sensitivity—Press and release the   button to increase shock sensor sensitivity 
by one step. The LCD transmitter beeps 2-times for each step increased in adjustment 
(and/or 1 vibrate if programmed). When the shock sensor adjustment reaches 
maximum sensitivity when the indicator bar is filled completely to the right 
. 
There are 21 levels of shock sensor adjustment, during sensor adjustment these levels 
are displayed on the indicator bar as listed below. 
NOTE: When the arm and disarm are programmed 
to a single button, then the AUX button is used 
to increase the sensitivity setting of the sensor. 
Sensor 
Adjustment
Level 
Bar Number and 
Indication 
0 
no bars displayed 
1 
bar 1 flashes 
2 
bar 1 solid 
3 
bar 1 solid, bar 2 flashes 
4 
bar 1-2 solid 
5 
bar 1-2 solid, bar 3 flashes 
6 
bar 1-3 solid 
7 
bar 1-3 solid, bar 4 flashes 
8 
bar 1-4 solid 
9 
bar 1-4 solid, bar 5 flashes 
10 
bar 1-5 solid 
11 
bar 1-5 solid, bar 6 flashes 
12 
bar 1-6 solid 
13 
bar 1-6 solid, bar 7 flashes 
14 
bar 1-7 solid 
15 
bar 1-7 solid, bar 8 flashes 
16 
bar 1-8 solid 
17 
bar 1-8 solid, bar 9 flashes 
18 
bar 1-9 solid 
19 
bar 1-9 solid, bar 10 flashes 
20 
bar 1-10 solid 