Specifications Sheet
-0/+5W
EN
1000 VDC
3
20 A
15 A
- 0.42 % / K
+0.059 % / K
- 0.32 % / K
46 °C ±2 °C
265 Wp
265 Wp
31.16 V
8.57 A
38.12 V
9.01 A
16.20%
197.3 Wp
28.90 V
6.89 A
36.20 V
7.21 A
260 Wp
260 Wp
30.90 V
8.48 A
37.78 V
8.93 A
15.98%
193.4 Wp
28.80 V
6.72 A
35.89 V
7.14 A
255 Wp
255 Wp
30.64 V
8.39 A
37.45 V
8.85 A
15.59%
189.6 Wp
28.56 V
6.64 A
35.58 V
7.08 A
250 Wp
250 Wp
30.38 V
8.29 A
37.12 V
8.76 A
15.28%
186.0 Wp
28.31 V
6.57 A
35.26 V
7.01 A
245 Wp
245 Wp
30.12 V
8.20 A
36.78 V
8.68 A
14.98%
182.3 Wp
28.07 V
6.49 A
34.94 V
6.94 A
240 Wp
240 Wp
29.86 V
8.10 A
36.45 V
8.59 A
14.67%
178.7 Wp
27.83 V
6.42 A
34.63 V
6.88 A
ASM6610P(BF) Series
Datasheet
Crystalline PV Module
Temperature coecient (Pmpp)
Temperature coecient (Isc)
Temperature coecient (Voc)
Normal operating cell temperature (NOCT)
STC
2
rated output (Pmpp)
ELECTRICAL SPECIFICATIONS
1
Maximum system voltage
Number of diodes
Reverse current loadability (IR)
Maximum series fuse rating
Warranted power output STC (Pnominal)
Rated voltage (Vmpp) at STC
Rated current (lmpp) at STC
Open circuit voltage (Voc) at STC
Short circuit current (Isc) at STC
Module eciency
Rated output (Pmpp) at NOCT
3
Rated voltage (Vmpp) at NOCT
Rated current (Impp) at NOCT
Open circuit voltage (Voc) at NOCT
Short circuit current (Isc) at NOCT
Standard sorted output
¹ Measuring uncertainity Pmpp: +/–3 %; Tolerance for Voc, Isc, Vmpp and Impp: +/–10 %
2
Standard test conditions that are dened as follows:
1.000 W/m² irradiation at a spectral density of AM 1.5 and a cell temperature of 25° C,
3
Nominal operating temperature of the cell at 800 W/m² irradiation, 20°C ambient temperature, wind speed of 1 m/s
4
Manufactured in an UL 1703 certied facility
240 245 250 255 260 265
4
Made in
Germany
For USA Market