User's Manual

ASUS A88XM-E 2-15
The values of the CPU Offset Voltage, VDDNB Offset Voltage, DRAM Voltage, and
SB 1.1V Voltage items are labeled in different colors, indicating the risk levels of high
voltage settings.
The system may need better cooling system to work stably under high voltage
settings.
2.5.11 DIGI+VRM
CPU Load Line Calibration [Auto]
Load‑line Calibration is dened by AMD VRM specications and affects CPU voltage. The
CPU working voltage will decrease proportionally to CPU loading. Higher load‑line calibration
would get higher voltage and better overclocking performance, but increase the CPU and
VRM thermal. This item allows you to adjust the voltage range from the following percentages
to boost the system performance: 0% (Regular), 60% (Medium), 80% (High), and 100%
(Extreme). Conguration options: [Auto] [Regular] [Medium] [High] [Extreme]
The actual performance boost may vary depending on your CPU speciation.
CPU/NB Load Line Calibration [Auto]
Allows you to select the CPU/NB Load‑Line Calibration mode. Conguration options: [Auto]
[Regular] [High] [Extreme]
CPU Current Capability [100%]
This item provides wider total power range for overclocking. A higher value brings a
wider total power range and extends the overclocking frequency range simultaneously.
Conguration options: [100%] [110%] [120%] [130%]
CPU/NB Current Capability [100%]
This item provides wider total power range for overclocking. A higher value brings a
wider total power range and extends the overclocking frequency range simultaneously.
Conguration options: [100%] [110%] [120%] [130%]
CPU Power Phase Control [Standard]
Phase number is the number of working VRM phase. Increasing phase number under heavy
system loading to get more transient and better thermal performance. Reducing phase
number under light system loading to increase VRM efciency.
[Standard] Proceeds phase control depending on the CPU loading.
[Optimized] Loads the ASUS optimized phase tuning prole.
[Extreme] Proceeds the full phase mode.
[Manual Adjustment] Allows manual adjustment.
DO NOT remove the thermal module when switching to Extreme and Manual Adjustment.
The thermal conditions should be monitored.