1U Rackmount Server Manual

6-10 Chapter 6: RAID conguration
UsingNewConguration
When a RAID set already exists, using the
NewConguration
command
erases the existing RAID conguration data. If you do not want to delete the
existing RAID set, use the
View/AddConguration
command to view or create
another RAID conguration.
To create a RAID set using the
NewConguration
option
1. From the
Management Menu
, select
Congure>NewConguration,
and
then press <Enter>.
Configure
Initialize
Objects
Rebuild
C h e c k
C l e a r E x i s t i ng Co n f i g u r a t i o n A n d S t a r t A N e w
E a s y
Configuration
N e w
Configuration
V i e w / A d d
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
2. Follow step 2 to 9 of the previous section:
UsingEasyConguration
.
3. Select
Size
from the
Virtual Drive
menu, and then press <Enter>.
4. Key-in the desired virtual drive size, and then press <Enter>.
5. Follow step 10 to 14 of the previous section:
UsingEasyConguration
to
create the RAID set.
Configure
Initialize
Objects
Rebuild
C h e c k
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
DNLIN
DNLIN
E a s y C o n f i g u r a t i o n - A R R A Y
V i r t u a l D r i v e ( s )
LD RAID Size #Stripes StripSz
Status
0 1 148.580GB 2 64 KB
ONLINE
V i r t u a l
RAID = 1
Units= MB
Size = 152146MB
DWC = Off
RA = On
Accept
SPAN = NO
E n t e r V D
Enter VD Size: 152146_
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option