Importing or Clearing a Foreign Conguration
A foreign conguration is a storage conguration that already exists on a
replacement set of drives that you install in a computer system. In addition, if one
or more drives are removed from a conguration, by a cable pull or drive removal,
for example, the conguration on those drives is considered a foreign conguration
by the RAID controller.
The WebBIOS CU allows you to import the foreign conguration to the RAID
controller, or to clear the conguration so you can create a new conguration using
these drives.
When you create a new conguration, the WebBIOS CU shows only the
uncongured drives. Drives that have existing congurations, including foreign
congurations, do not appear. To use drives with existing congurations, you
must rst clear the conguration on those drives.
Foreign conguration(s) found on adapter
Press any key to continue or ‘C‘ to load the conguration utility,
or ‘F‘ to import foreign conguration(s) and continue.
If WebBIOS CU detects a foreign conguration, the following screen appears when
enter the WebBIOS CU.
If a foreign conguration is detected during POST, press <C> when the following
screen appears.
Follow these steps to import or clear a foreign conguration:
1. Click the drop-down list to show the congurations.
The GUID (Global Unique Identier) entries on the drop-down list are OEM
names and will vary from one installation to another.
1 Virtual Drive(s) handled by BIOS
Press <Ctrl><H> for WebBIOS or press <Ctrl><Y> for Preboot CLI
When the following screen appears, press <Ctrl+H> to enter the WebBIOS CU.