2-40 Chapter 2: RAID conguration
3. Perform one of the following steps:
Click Preview to preview
the foreign congurations.
The Foreign Conguration
Preview screen appears, as
shown in the right gure.
Click Clear to clear the foreign
congurations and reuse the
drives for another virtual drive.
If you click Cancel, it cancels the
importation or preview of the foreign
conguration.
The right panel shows the virtual drive properties of the foreign conguration.
In this example, there are two RAID1 virtual drives with 67.843GB each. The
left panel shows the drives in the foreign conguration.
4. Click Import to import this foreign conguration(s) and use it on this
controller.
Foreign Configurations in Cable Pull and Drive Removal Scenarios
If one or more drives are removed from a conguration, by a cable pull or
drive removal, for example, the conguration on those drives is considered a
foreign conguration by the RAID controller.
Use the Foreign Conguration Preview screen to import or clear the
foreign conguration in each case.
The following scenarios can occur with cable pulls or physical drive removals.
If you want to import the foreign conguration in any of the following scenarios,
you should have all the drives in the enclosure before you perform the import
operation.
1. Scenario #1: If all of the drives in a conguration are removed
and re-inserted, the controller considers the drives to have foreign
congurations.
Import or clear the foreign conguration. If you select Import, automatic
rebuilds will occur in redundant virtual drives.
Start a consistency check immediately after the rebuild is complete to ensure
data integrity for the virtual drives.
2. Select a conguration or All Congurations.