User Manual

ASUS ESC4000 Series 6-17
3. After selecting the drive to rebuild, press <F10>. When prompted, press <Y>
to rebuild the drive.
4. When rebuild is complete, press any key to continue.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
ONLIN A00-00
RBLD A00-01
0
1
Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
LSI Software RAID Conguration Utility Ver A.60 Jul 30, 2008
BIOS Version A.08.09161344R
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
6.2.5 Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences in
data redundancy depending on the selected option in the
Objects>Adapter
menu.
The
Check Consistency
command is available only for virtual drives included
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the
Check Consistency
command
1. From the
Management Menu
, select
Check Consistency
, and then press
<Enter>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Software RAID Conguration Utility Ver A.60 Jul 30, 2008
BIOS Version A.08.09161344R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option