Selectadestinationdiskwiththesamesizeastheoriginalharddisk.
6.3.6 Rebuilding the RAID
ThisoptionisonlyfortheRAID1set.
Rebuilding the RAID with other non-RAID disk
IfanyoftheSATAharddiskdrivesincludedintheRAID1arrayfailed,thesystemdisplays
thestatusoftheRAIDvolumeas“Degraded”duringPOST.YoucanrebuildtheRAIDarray
withotherinstallednon-RAIDdisks.
TorebuildtheRAIDwithothernon-RAIDdisk:
1. DuringPOST,press<Ctrl>+<I>attheprompttoentertheIntelRapidStorage
TechnologyoptionROMutility.
2. Ifthereisanon-RAIDSATAHardDiskavailable,theutilitywillpromptyoutorebuild
theRAID.Presstheup/downarrowkeystoselectthedestinationdiskthenPress
<Enter>tostarttherebuildingprocess,orpress<ESC>toexit.
6.3.5 Exiting the Intel
®
Rapid Storage Technology enterprise
SATA Option ROM utility
Toexittheutility:
1. Fromtheutilitymainmenu,select
4. Exit
thenpress<Enter>.
2. Press<Y>toexitorpress<N>toreturntotheutilitymainmenu.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[ DEGRADED VOLUME DETECTED ]
Are you sure you want to exit? (Y/N):
[ CONFIRM EXIT ]