GigaX Series Layer 2 Managed Switch User Guide
GigaX Series L2 Managed Switch User Guide E2211 First Edition V1 July 2005 Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (ASUS).
GigaX Series L2 Managed Switch User’s Guide Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
GigaX Series L2 Managed Switch User Guide ASUS contact information ASUSTeK COMPUTER INC. (Asia-Pacific) Address: General Tel: General Fax: Web Site: Technical Support MB/Others (Tel): Notebook (Tel): Desktop/Server (Tel): Support Fax: 150 Li-Te Road, Peitou, Taipei, Taiwan 112 +886-2-2894-3447 +886-2-2894-7798 www.asus.com.
GigaX Series L2 Managed Switch User Guide Table of Contents 1 2 3 4 Introduction............................................................................... 11 1.1 L2 managed features ..................................................... 11 1.2 Conventions used in this document ............................... 12 1.2.1 Notations......................................................... 12 1.2.2 Typography..................................................... 12 1.2.3 Symbols ........................
GigaX Series L2 Managed Switch User Guide 6 4.3 System Pages ................................................................30 4.3.1 Management ...................................................30 4.3.2 IP Setup ..........................................................32 4.3.3 Administration .................................................34 4.3.4 Reboot.............................................................35 4.3.5 Firmware Upgrade ..........................................35 4.
GigaX Series L2 Managed Switch User Guide 4.8.2 4.8.3 4.9 5 6 7 8 Error Group..................................................... 68 Historical Status.............................................. 69 Save Configuration......................................................... 71 Console Interface ..................................................................... 72 5.1 Power On Self Test ........................................................ 73 5.1.1 Boot ROM Command Mode .......................
GigaX Series L2 Managed Switch User Guide List of Figures Figure 1. GigaX L2 managed switch package contents ................13 Figure 2. Front panel .....................................................................14 Figure 3. Rear panel ......................................................................16 Figure 4. Overview of Hardware Connections...............................19 Figure 5. Login and IP setup Screen .............................................21 Figure 6. Login Screen .
GigaX Series L2 Managed Switch User Guide Figure 26. Tagged VLAN................................................................. 51 Figure 27. Default Port VLAN and CoS........................................... 52 Figure 28. Cos Queue Mapping ...................................................... 54 Figure 29. Community Table ........................................................... 55 Figure 30. Host Table...................................................................... 56 Figure 31.
GigaX Series L2 Managed Switch User Guide List of Tables Table 1. Front panel labels and LEDs ..........................................15 Table 2. Technical specifications .................................................16 Table 3. LED Indicators................................................................20 Table 4. Port color description......................................................27 Table 5. Commonly used buttons and icons ................................29 Table 6.
GigaX Series L2 Managed Switch User Guide 1 Introduction Congratulations on becoming the owner of the ASUS GigaX L2 managed switch! You may now manage your LAN (local area network) through a friendly and powerful user interface. This user guide tells you how to set up the GigaX L2 managed switch, and how to customize its configuration to get the most out of this product. 1.
GigaX Series L2 Managed Switch User Guide • LEDs for port link status • LEDs system, redundant power supply (RPS), and fan status 1.2 Conventions used in this document 1.2.1 Notations • Acronyms are defined the first time they appear in text and in the glossary. • For brevity, the GigaX switch is referred to as “the switch.” • The terms LAN and network are used interchangeably to refer to a group of Ethernet-connected computers at one site. 1.2.
GigaX Series L2 Managed Switch User Guide 2 Getting to know the GigaX 2024X 2.1 Package contents The GigaX 2024X switch package comes with the following items: • GigaX 2024X ( 26-port) L2 managed switch • AC Power cord • Null modem cable for console interface (DB9) • Rack installation kit (two brackets with six #6-32 screws) • USB cable for console interface • Installation CD-ROM • User Manual • Quick installation guide Figure 1.
GigaX Series L2 Managed Switch User Guide 2.2 Front Panel The front panel includes LED indicators that show the system, RPS, fan, and port status. Figure 2.
GigaX Series L2 Managed Switch User Guide Table 1.
GigaX Series L2 Managed Switch User Guide 2.3 Rear Panel The switch rear panel contains the ports for the data and power connections. Figure 3. Rear panel No. Label Description 1 Power Connector Connects to the supplied power cord 2 RPS Redundant Power Supply connector 3 FAN1 – FAN2 Replaceable system fans 2.4 Table 2. Technical specifications Technical specifications Physical Dimensions 43.5mm(H) X 444 mm(W) X 265mm(D) Power Input Consumption 100-240V AC/2.
GigaX Series L2 Managed Switch User Guide 3 Quick start guide This section provides the basic instructions to set up the GigaX environment. Refer also to the GigaX Series Installation Guide. Part 1 shows you how to install the GigaX on a flat surface or on a rack. Part 2 provides instructions to set up the hardware. Part 3 shows you how to configure basic settings on the GigaX.
GigaX Series L2 Managed Switch User’s Guide 3.2 Part 2 — Setting up the switch Connect the device to the power outlet, and your computer or network. See Figure 4. 3.2.1 Connect the console port For console management, use an RS232 (DB9) or a USB cable to connect the switch. If you want to use WEB interface, connect your PC to the switch using the Ethernet cable. 3.2.2 Connect to the computers or a LAN You can use Ethernet cable to connect computers directly to the switch ports.
GigaX Series L2 Managed Switch User Guide RS-232 Console Management RPS USB Cat 5 Ethernet cables Expansion hub/switch LAN computers Figure 4.
GigaX Series L2 Managed Switch User’s Guide Table 3. LED Indicators No. LED Description 1 System Solid green indicates that the device is turned on. If this light is off, check if the power adapter if attached to the switch and plugged into a power source. 2 Switch ports Solid green indicates that the device can communicate with the LAN, or flashing when the device is sending or receiving data from your LAN computer.
GigaX Series L2 Managed Switch User Guide 3. Make sure the settings of your terminal emulation software as follows: a) Choose the appropriate serial port number b) Set the data baud rate to 9600 c) Set the data format to no parity, 8 data bits and 1 stop bit d) No flow control e) Set VT1000 for emulation mode 4. After setting up the terminal, you can see the prompt “(ASUS)%” on the terminal. 5. Type “login” to access the command line interface. The default user name is “admin”.
GigaX Series L2 Managed Switch User’s Guide 3.3.2 Setting up through the Web interface To successfully connect your PC to the switch, your PC must a valid IP in your network. Contact your network administrator to obtain a valid IP for the switch. If you wish to change the default IP address of the switch, follow section 3.3.1 to change the IP address.
GigaX Series L2 Managed Switch User Guide Default User Name: Default Password: admin (no password) You can change the password at any time (see section 5.3.1 System Commands). 3. To setup a new IP address, click “System”, then “IP Setup” (see Figure 8). Fill in the IP address, network mask and default gateway, then click . 4. If your new address is different from the default, the browser can not update the switch status window or retrieve any page. This is normal.
GigaX Series L2 Managed Switch User’s Guide Figure 7.
GigaX Series L2 Managed Switch User Guide 4 Management with the Web Interface The switch provides Web pages that allow switch management through the Internet. The program is designed to work best with Microsoft Internet Explorer® 5.5, or later versions. NOTE: Netscape is not supported. 4.1 Log into Web user interface 1. From a PC, open your web browser, type the following in the web address (or location) box, and press : http://192.168.1.1 This is the factory default IP address for the switch.
GigaX Series L2 Managed Switch User’s Guide Use the following defaults the first time you log into the program. You can change the password at any time through CLI interface (see section 5.3.1 ) Default User Name: admin Default Password: The home page appears each time you log into the program.(See Figures 9). Figure 9.
GigaX Series L2 Managed Switch User Guide 4.2 Functional layout Typical web page consists of three separate frames. The top frame has a switch logo and front panel as shown in Figures 10. This frame remains on the top of the browser window all the times and updates the LED status periodically. See Table 4 for the LED definitions. See Table 5 for the color status description. Figure 10. Top frame Table 4.
GigaX Series L2 Managed Switch User’s Guide Figure 11. Expanded Menu List The right frame displays configuration pages or graphics for the statistics. See section 4.3 for details.
GigaX Series L2 Managed Switch User Guide 4.2.1 Menu navigation tips • To expand a group of related menus, click on the corresponding group name. The sign will change to after expansion. • To contract a group of related menus: click on the corresponding group name. The sign will appear next to the group name. • To open a specific configuration page, click on the desired menu item. • 4.2.
GigaX Series L2 Managed Switch User’s Guide 4.3 System Pages System pages include management, IP setup, administration, reboot, and firmware update function. 4.3.
GigaX Series L2 Managed Switch User Guide Figure 12.
GigaX Series L2 Managed Switch User’s Guide 4.3.2 IP Setup The switch supports dynamic IP and static IP assignment. The dynamic IP is get from a DHCP server within the same VLAN. The IP Setup page contains the following editable information: VLAN ID: Specify a VLAN ID to system management interface. It is necessary to be within the same VLAN for management usages. DHCP Client: Enable DHCP to get a dynamic IP address, or disable DHCP to specify a static IP address.
GigaX Series L2 Managed Switch User Guide Figure 13.
GigaX Series L2 Managed Switch User’s Guide 4.3.3 Administration The Administration page allows you enable or disable the authentication for web user by password protection. The default setting for web access does not require any authentication. To save any changes and make it effective immediately, click . Use to refresh the setting, as shown in Figure 14. When you enable the password protection, you have to login again immediately. You can change the password at any time through the CLI interface.
GigaX Series L2 Managed Switch User Guide 4.3.4 Reboot The Reboot page contains a system. button. Clicking the button reboots the Rebooting the system stops the network traffic and terminates the Web interface connection. Figure 15. Reboot 4.3.5 Firmware Upgrade The Firmware page contains the following information: Hardware Version: shows the hardware revision number. Boot ROM Version: shows the version of the boot code Firmware Version: shows the current running firmware version.
GigaX Series L2 Managed Switch User’s Guide Enter the firmware location into the firmware space directly, or click to choose the file name of the firmware from prompt window. Click to update the switch firmware. See Figure 16 for reference. Clicking the upload button loads the assigned firmware to the switch, then reboot system after a successful firmware update. You have to re-login to Web interface again Figure 16.
GigaX Series L2 Managed Switch User Guide 4.4 Physical Interface The Physical Interface displays the Ethernet port status in real time. You can configure the port in following fields: Port: select the port to configure Admin: disable/enable the port Mode: set the speed and duplex mode Flow Control: enable/disable 802.
GigaX Series L2 Managed Switch User’s Guide Figure 17.
GigaX Series L2 Managed Switch User Guide 4.5 Bridge The Bridge page group contains most layer 2 configurations, like link aggregation, STP etc.. 4.5.1 Spanning Tree The configuration page for Spanning Tree Protocol can disable and enable the feature in runtime. This page consists of three parts. The first part shows the root information. It tells user the STP setting about the root switch. The second part is the STP setting.
GigaX Series L2 Managed Switch User’s Guide Edge Port: All ports are set to be edge ports by default. Edge port becomes STP port when BPDU is received. Also, it takes very short time for an edge port to be in forwarding state. Point to Point: Auto/Yes/No. A full duplex link is considered as a point to point link. Otherwise, it is a shared link. Point to point link may have less convergence time. Auto is recommended in most cases. Click to make the settings effective. Click settings to current value.
GigaX Series L2 Managed Switch User Guide Name: the group name. Trunk ID: a number to identify the trunk group besides the group name. LACP: Enable/Disable LCAP on selected trunk. LACP mode is fixed to be Active. Remove Trunk: Remove the selected trunk. Port Icons: these port icons are listed in a way like the front panel. You have to click on the icon the select the group members. The port can be removed from the group by clicking the selected port again.
GigaX Series L2 Managed Switch User’s Guide group consists of port 1 and 2. If the VLAN of port 1 changes, the VLAN of port 2 also changes with port 1. Figure 19. Link aggregation 4.5.3 Mirroring Mirroring, together with a network traffic analyzer, helps you monitor network traffics. You can monitor the selected ports for egress or ingress packets. Mirror Mode: Enables or disables the mirror function for the selected group.
GigaX Series L2 Managed Switch User Guide Monitor Port: Receives the copies of all the traffics in the selected mirrored ports. The monitor port can not belong to any link aggregation group. The monitor port can not operate as a normal switch port. It does not switch packets or do address learning. Click to make the setting send to the switch (HTTP server). Click to refresh the settings to current value. Figure 20.
GigaX Series L2 Managed Switch User’s Guide Static Multicast This page can add multicast addresses into the multicast table. The switch can hold up to 256 multicast entries. All the ports in the group will forward the specified multicast packets to other ports in the group. Show Group: selects “Add a new Group” to enter a new entry. Or select an existing group address to display MAC Address: selects the multicast address VLAN: selects the vlan group Click to make the setting effective.
GigaX Series L2 Managed Switch User Guide 4.5.4 IGMP Snooping IGMP snooping helps to reduce the multicast traffics on the network by allowing the IGMP snooping function to be turned on or off. When turned on, the switch snoops the IGMP packets and puts the new group into the multicast table. However, if the static entries occupy all 256 spaces, the IGMP snoop does not work normally. The switch only allows 256-layer 2 multicast group. Figure 22. IGMP Snooping 4.5.
GigaX Series L2 Managed Switch User’s Guide Figure 23. Traffic Control 4.5.6 Dynamic Addresses This page displays the result of dynamic MAC address lookup by port, VLAN ID, or specified MAC address. The dynamic address is the MAC address learned by switch, it will age out from the address table if the address is not learned again during the age time. User can set the age time by entering a to save the valid number from 15 to 3825 in seconds. Then click on new age value.
GigaX Series L2 Managed Switch User Guide Figure 24.
GigaX Series L2 Managed Switch User’s Guide 4.5.7 Static Addresses You can add a MAC address into the switch address table. The MAC address added by this way will not age out from the address table. We call it static address. MAC Address: enter the MAC address VLAN ID: enter the VLAN ID that the MAC belongs Port Selection: select the port which the MAC belongs Click on when you create a new static MAC address by the above information. Then you will see the new added entry shows in the address window.
GigaX Series L2 Managed Switch User Guide Figure 25. Static Address 4.5.8 Tagged VLAN You can set up to 256 VLAN groups and show VLAN group in this page. There is a default VLAN created by the switch. It cannot be removed at all. This feature prevents the switch from malfunctions. You can remove any existed VLAN except the default VLAN. You can assign the port to be a tagged port or an untagged port by toggling the port button.
GigaX Series L2 Managed Switch User’s Guide If one untagged port belongs to two or more VLAN groups at the same time, it will confuse the switch and cause flooding traffics. To prevent it, the switch only allows one untagged port belongs to one VLAN at the same time. That is, the untagged port belongs to the VLAN group which is called “PVID” and configured in the “Default Port VLAN & CoS” page.
GigaX Series L2 Managed Switch User Guide Figure 26.
GigaX Series L2 Managed Switch User’s Guide 4.5.9 Default Port VLAN and CoS Some VLAN tag related field settings for each port are included in this page. It includes: Port: select the port to configure PVID: port-based VLAN ID. Every untagged packet received from this port will be tagged with this VLAN group ID CoS (Class of Service) value: every untagged packet received from this port will be assigned to this CoS in the VLAN tagged. Click on to change the content in the port list window.
GigaX Series L2 Managed Switch User Guide 4.5.10 CoS Queue Mapping The switch supports 4 egress queues for each port. For each queue, you can specify the scheduling types as follows: • Strict priority scheduling: each CoS value can map into one of the four queues. The queue 4 has the highest priority to transmit the packets. And packets in the low-priority queue do not transmit until all the high-priority queues become empty. In Strict priority scheduling, weight settings always zero.
GigaX Series L2 Managed Switch User’s Guide Figure 28.
GigaX Series L2 Managed Switch User Guide 4.6 SNMP This group offers the SNMP configuration including Community Table, Host Table, and Trap Setting. To provide more secure management and access control, SNMPv3 is supported. 4.6.1 Community Table You can type different community names and specify whether the community has the privilege to make a setting (write access) by checking the box. Click to save the configuration permanently or to refresh the page. Figure 29.
GigaX Series L2 Managed Switch User’s Guide 4.6.2 Host Table This page links host IP address to the community name that is entered in Community Table page. Type an IP address and select the community name from the drop-down list. Click permanently or to save the configuration to refresh the page. Figure 30.
GigaX Series L2 Managed Switch User Guide 4.6.3 Trap Setting By setting trap destination IP addresses and community names, you can enable SNMP trap function to send trap packets in different versions(v1 or v2c). to save the configuration permanently or Click refresh the page. to Figure 31. Trap Setting 4.6.4 VACM Group VACM(View-based Access Control Model) Group is used to configure the information of SNMPV3 VACM Group. Group Name: enter the security group name.
GigaX Series L2 Managed Switch User’s Guide Write View Name: enter the Write View Name that the Group belongs. The related SNMP message is Set. Notify View Name: enter the Notify View Name that the Group belongs. The related SNMP messages are Trap,Report.. Security Model: enter the Security Model Name that the Group belongs. Any is suitable for v1,v2,v3. USM is SNMPv3 related. Security level: enter the Security level Name that the Group belongs. Only NoAuth, AuthNopriv, AuthPriv can be chosen.
GigaX Series L2 Managed Switch User Guide Figure 32. VACM Group 4.6.5 VACM View VACM (View-based Access Control Model) View is used to view the information of SNMPV3 VACM Group. View Name: enter the security group name. View Type: select the View Type that the View belongs. Included or Excluded when View Subtree matches the Oid in the SNMPv3 message. View Subtree: enter the View Subtree that the View belongs. The Subtree is the Oid to match the Oid in the SNMPv3 message.
GigaX Series L2 Managed Switch User’s Guide Click on the when you create a new VACM View entry by the above information. Then you will see the new added entry shows in the view window. You can remove the existed views by selecting the entry with the mouse, then . The button updates the existed VACM View clicking on to save effectively. Click to refresh the entries. Click settings to current value. To make the configuration effective, please go to "Save Configuration" page, then click on . Figure 33.
GigaX Series L2 Managed Switch User Guide Name: enter Name combined with Engine ID that should match the Name and Engine ID in the Manager. Auth Protocol: enter the Auth Protocol that Engine ID and Name belong. Only NoAuth ,MD5, SHA1 can be chosen. If the NoAuth is chosen, there is no need to enter password. Auth Password: enter the password that the Auth Protocol belongs. The password needs at least 8 characters or digits. Priv Protocol: enter the Priv Protocol that Engine ID and Name belong.
GigaX Series L2 Managed Switch User’s Guide Figure 34.
GigaX Series L2 Managed Switch User Guide 4.7 Security The switch has the 802.1x port-based security feature. Only authorized hosts are allowed to access the switch port. Traffic is blocked for hosts failed to authenticate themselves. The authentication service is provided by a RADIUS server or the local database in the switch. The switch also supports dynamic VALN assignment through 802.1x authentication process.
GigaX Series L2 Managed Switch User’s Guide • Multi-host: If enabled, all hosts connected to the selected port are allowed to use the port if one of the hosts passed the authentication. If disabled, only one host among other hosts passed the authentication is allowed to use the port. • Authentication Control: If 'force authorized' is selected, the selected port is forced to be authorized. Thus, traffic from all hosts is allowed to pass.
GigaX Series L2 Managed Switch User Guide 4.7.2 Dial-In User Dial-in User is used to define users in the local database of the switch. • User Name: New user name. • Password: Password for the new user. • Confirm Password: Enter the password again. • Dynamic VLAN: Specify 802.1x-authenticated clients. VLAN ID to add the new user. Click Please click finished the modifications. Click selected user.
GigaX Series L2 Managed Switch User’s Guide 4.7.3 RADIUS In order to use external RADIUS server, the following parameters are required to be setup: • Authentication Server IP: The IP address of the RADIUS server. • Authentication Server Port: The port number for the RADIUS server is listening to. • Authentication Server Key: The key is used for communications between GigaX and the RADIUS server. • Confirm Authentication Key: Re-type the key entered above.
GigaX Series L2 Managed Switch User Guide 4.8 Statistics Chart The Statistics Chart pages provide network flow in different charts. You can specify the period time to refresh the chart. You can monitor the network traffic amount in different graphic chart by these pages. Most MIB-II counters are displayed in these charts. Click Refresh Rate to set the period for retrieving new data from the switch. You can differentiate the statistics or ports by selecting Color.
GigaX Series L2 Managed Switch User’s Guide Figure 38. Traffic comparison 4.8.2 Error Group Select the Port and display Color, then click the Draw, the statistics window shows you all the discards or error counts for the specified port. The data is updated periodically.
GigaX Series L2 Managed Switch User Guide Figure 39. Error group 4.8.3 Historical Status You can display information for different ports and statistics items in this chart. Since this shows the history of the statistics information, the chart can keep the old data even it is refreshed.
GigaX Series L2 Managed Switch User’s Guide Figure 40.
GigaX Series L2 Managed Switch User Guide 4.9 Save Configuration To save configuration permanently, you should click also takes effective after a successful save. . The setting Sometimes you may want to reset the switch configuration, you can click on to reset the configuration file to factory default. Of course, a system reboot will follow this restoration process. You will lose all the configurations when you choose to restore the factory default configurations. Figure 41.
GigaX Series L2 Managed Switch User’s Guide 5 Console Interface This chapter describes how to use console interface to configure the switch. The switch provides RS232 and USB connectors to connect your PC. Use a terminal emulator on your PC such as HyperTerminal and command line interpreter to configure the switch. You have to set up the terminal emulator with baud rate 9600, 8 bit data, no parity, and 1 stop bit, and no flow control.
GigaX Series L2 Managed Switch User Guide 5.1 Power On Self Test POST is executing during the system booting time. It tests system memory, LED and hardware chips on the switchboard. It displays system information as the result of system test and initialization. You can ignore the information until the prompt, “(ASUS) %”, appears (see Figure 43). Figure 42.
GigaX Series L2 Managed Switch User’s Guide 5.1.1 Boot ROM Command Mode During the POST process, you can enter a “Boot ROM Command” mode by pressing key as shown in Figure 43. Figure 43 shows dual images in the switch. Enter the “?” key to show the help messages for all available commands. Although the commands are helpful in some situation, we STRONGLY suggest users not to use them if you don’t know the command function. Figure 43.
GigaX Series L2 Managed Switch User Guide 5.1.2 Boot ROM Commands Type “?” in the boot mode to display the valid commands list. Table 6.
GigaX Series L2 Managed Switch User’s Guide 5.2 Login and Logout By typing “login” to enter the CLI mode, you have to give a valid user name and password. As the first time login, you can enter “admin” as the user name and bypass the password. For security reason, please change the user name and password after login. Once you forget the use name and password, you may contact ASUS support team or erase the whole configuration file in the Boot ROM Command mode.
GigaX Series L2 Managed Switch User Guide If you put a name in the name description field, the switch system name will be changed into the new one. [System Contact] Displays the detail information of contact about the switch. This is an RFC-1213 defined MIB object in System Group, and provides contact information on the managed node.
GigaX Series L2 Managed Switch User’s Guide Figure 44. SYS commands [VLAN ID] Display the VLAN ID for the switch. It is necessary to be within the same VLAN for management . CLI command: net interface vlan sw0 [DHCP Client] Enable DHCP to get a dynamic IP address, or disable DHCP to specify a static IP address. If you enable DHCP, you can renew or release the IP address for the switch, and use show command to display the dynamic IP address.
GigaX Series L2 Managed Switch User Guide [Network Mask] Displays the subnet mask for the switch. CLI command: net interface ip sw0 < IP address> [Default Gateway] Displays the IP address of the default gateway. This field is necessary if the switch network contains one or more routers.
GigaX Series L2 Managed Switch User’s Guide 5.3.2 Physical Interface Commands [Admin] [Enable/Disable] Displays the port admin status and allows user to turn the port on or off. CLI command : l2 port admin [Mode] [Auto/10M-Half/10M-Full/100M-Half/100M-Full/1G-Full] Displays the current speed and duplex mode of the port. The speed and duplex mode can be automatically detected when auto-negotiation is enabled on a port.
GigaX Series L2 Managed Switch User Guide [Hello Time] [Forward Delay] [Max Age] [Bridge Priority] Displays the current STP/RSTP bridge parameters setting. CLI command : l2 stp bridge set Hello Time (1..10 seconds):[old Hello Time] Max Age (6..40 seconds):[ old Max Age] Forward Delay (4..30 seconds):[ old Forward Delay] Bridge Priority (0..
GigaX Series L2 Managed Switch User’s Guide CLI command : l2 stp port retrieve [Show Trunk] Displays a specific trunk group settings. User can create a new trunk group by specify a unique trunk ID, a trunk name description, the port selection criterion (rtag), LACP mode (enabled or disable), and its trunk group member ports. CLI command : l2 trunk show [Create Trunk] Creates a new trunk group by giving trunk ID, rtag, name, LACP mode and port numbers.
GigaX Series L2 Managed Switch User Guide CLI command : l2 port lacppri [Reload] Restores the previous saved settings of trunk from configuration file. CLI command : l2 trunk retrieve [Mirror Mode] [Enable/Disable] [Monitor Port] [port number] Displays the mirroring settings of the switch.
GigaX Series L2 Managed Switch User’s Guide vlan id [1 by default]: port list [format: 1 2 3 4- 26/* for all ports]: [Remove Multicast Group] Allows user to delete a static multicast group entry from multicast group table by given a MAC address and VLAN ID. CLI command : l2 mcast delete mac address [format: xx:xx:xx:xx:xx:xx]: vlan id: [Reload] Restores the previous saved settings from configuration file.
GigaX Series L2 Managed Switch User Guide CLI command : l2 rate set [ ] [Reload] Restores the previous saved settings from configuration file. CLI command : l2 rate retrieve [Aging Time] User can set the ARL (Address Resolution Logic) entries aging time by setting the aging time value.
GigaX Series L2 Managed Switch User’s Guide [MAC Address] [VLAN ID] [Port Selection] User can add or modify a static ARL entry by specifying a MAC address, VLAN ID, port number, and trunk ID. CLI command : l2 arl static [Remove] Static ARL entries can be deleted by indicating the MAC address and its VLAN ID. These two-field combination is formed as unique entry in ARL table.
GigaX Series L2 Managed Switch User Guide CLI command : l2 vlan create CLI command : l2 vlan add CLI command : l2 vlan remove CLI command : l2 vlan utportadd [Remove VLAN] Allows user to completely destroy an existing VLAN. CLI command : l2 vlan delete [Reload] Restores the previous saved settings from configuration file.
GigaX Series L2 Managed Switch User’s Guide CLI command : l2 port retrieve [CoS] [Map] Allows user to map the CoS priority (with range of 0-7) for a buffer queue (total of 4, with queue ID of 1-4). CLI command : l2 cos map [Scheduling Algorithm] [Strict/WRR] Allows user to set scheduling with strict priority based or weight priority based. CLI command : l2 cos sched [Reload] Restores the previous saved settings from configuration file.
GigaX Series L2 Managed Switch User Guide This action will modify all hosts with community string from 'old community' to 'new community'. Are you sure? (y/n):[y] Get privileges: [y, always turn on by default] Set privileges? (y/n):[n] Allows user to delete a community entry from community table.
GigaX Series L2 Managed Switch User’s Guide Host IP/Subnet (old IP address): Netmask (old netmask): Community (old community string): Allows user to delete a host entry from host table. CLI command : snmp host delete Entry id (table index): [Reload] Restores the previous saved settings from configuration file.
GigaX Series L2 Managed Switch User Guide Community (old community string): Allows user to delete a trap entry from trap table. CLI command : snmp trap delete Trap table entry (table index): [Reload] Restores the previous saved settings from configuration file.
GigaX Series L2 Managed Switch User’s Guide Notify View Name: User can modify a VACM entry in the Group by reassigning its allowed group name, read view name, write view name, notify view name, security model, security level and context match.
GigaX Series L2 Managed Switch User Guide [View Name] [View Type] [View Subtree] [View Mask] VACM (View-based Access Control Model) View is used to view the information of SNMPV3 VACM Group. A VACM View entry contains a view name, view type, view subtree and view mask.
GigaX Series L2 Managed Switch User’s Guide [Engine Id] [Name] [Auth Protocol] [Auth Password] [Priv Protocol] [Priv Password] USM(User-based Security Model) User is used to configure the information of SNMPV3 USM User. A USM User entry contains a engine Id, name, auth protocol, auth password, priv protocol and priv password.
GigaX Series L2 Managed Switch User Guide AuthPassword: (old auth password string) < new auth password string> Priv Protocol [oid]: (old priv protocol oid string) < new priv protocol oid string > Priv Password: (old priv password string) < new priv password string > Allows user to delete a USM User entry. CLI command : snmp snmpv3 usmuser delete USM user entry: [Reload] Restores the previous saved settings from configuration file. CLI command : snmp snmpv3 usmuser retrieve 5.3.
GigaX Series L2 Managed Switch User’s Guide CLI command : security dot1x bridge quietperiod [Retransmission Time] Allows user to set up the retransmission time. CLI command : security dot1x bridge retxtime [Max Reauthentication Attempts] Allows user to set up the max number of the reauthentication attemps.
GigaX Series L2 Managed Switch User Guide [User Name] [Password] [Confirm Password] [Dynamic VLAN] Create users in the local database of the switch for 802.1x authentication. A user entry contains a user name, password and dynamic VLAN.
GigaX Series L2 Managed Switch User’s Guide [Authentication Server Port] [Authentication Server Key] [Confirm Authentication Key] Allows user to config the RADIUS server IP, server port and server key .
GigaX Series L2 Managed Switch User Guide [Show Generating Status] Show the SSH key generating status. It will display “success” or “SSH keys generated fail” or “system is generating keys ...”.
GigaX Series L2 Managed Switch User’s Guide 5.4 Miscellaneous Commands sys time uptime: shows the time since the system boot up.
GigaX Series L2 Managed Switch User Guide 6 IP Addresses, Network Masks, and Subnets 6.1 IP Addresses This section pertains only to IP addresses for IPv4 (version 4 of the Internet Protocol). IPv6 addresses are not covered. This section assumes basic knowledge of binary numbers, bits, and bytes. For details on this subject, see Appendix 6. IP addresses, the Internet's version of telephone numbers, are used to identify individual nodes (computers or devices) on the Internet.
GigaX Series L2 Managed Switch User’s Guide Table 7. IP address structure Field1 Field2 Class A Network ID Host ID Class B Network ID Class C Network ID Field3 Field4 Host ID Host ID Following are examples of valid IP addresses: Class A: 10.30.6.125 (network = 10, host = 30.6.125) Class B: 129.88.16.49 (network = 129.88, host = 16.49) Class C: 192.60.201.11 (network = 192.60.
GigaX Series L2 Managed Switch User Guide 6.1.2 Network classes The three commonly used network classes are A, B, and C. (There is also a class D but it has a special use beyond the scope of this discussion.) These classes have different uses and characteristics. Class A networks are the Internet's largest networks, each with room for over 16 million hosts. Up to 126 of these huge networks can exist, for a total of over 2 billion hosts.
GigaX Series L2 Managed Switch User’s Guide 6.2 Subnet masks A mask looks like a regular IP address, but contains a pattern of bits that tells what parts of an IP address are the network ID and what parts are the host ID: bits set to 1 mean "this bit is part of the network ID" and bits set to 0 mean "this bit is part of the host ID." Subnet masks are used to define subnets (what you get after dividing a network into smaller pieces).
GigaX Series L2 Managed Switch User Guide The two extra bits in Field 4 can have four values (00, 01, 10, 11), so there are four subnets. Each subnet uses the remaining six bits in field4 for its host IDs, ranging from 0 to 63. Sometimes a subnet mask does not specify any additional network ID bits, and thus no subnets. Such a mask is called a default subnet mask. These masks are: Class A: Class B: Class C: 255.0.0.0 255.255.0.0 255.255.255.
GigaX Series L2 Managed Switch User’s Guide 7 Troubleshooting This section gives instructions for using several IP utilities to diagnose problems. A list of possible problems with suggestion actions is also provided. All the known bugs are listed in the release note. Read the release note before you set up the switch. Contact Customer Support if these suggestions do not resolve the problem. 7.1 Diagnosing problems using IP utilities 7.1.
GigaX Series L2 Managed Switch User Guide Figure 45. Using the ping utility If the target computer cannot be located, you will receive the message “Request timed out.” Using the ping command, you can test whether the path to the switch is working (using the pre-configured default LAN IP address 192.168.1.1) or another address you assigned. You can also test whether access to the Internet is working by typing an external address, such as that for www.yahoo.com (216.115.108.243).
GigaX Series L2 Managed Switch User’s Guide 7.1.2 nslookup You can use the nslookup command to determine the IP address associated with an Internet site name. You specify the common name, and the nslookup command looks up the name on your DNS server (usually located with your ISP). If that name is not an entry in your ISP’s DNS table, the request is then referred to another higher-level server, and so on, until the entry is found. The server then returns the associated IP address.
GigaX Series L2 Managed Switch User Guide 7.2 Replacing defective fans Turn off the power of the switch when you remove the fan module on the rear side of the switch. When any one of the switch fans (located on the rear panel) becomes defective, you can easily replace it following these steps. 1. Unlock the fan module by loosening the thumbscrew that secures it to the rear panel. Figure 47. Loosening the thumbscrew 2. Carefully pull the module out as shown. Figure 48.
GigaX Series L2 Managed Switch User’s Guide 3. Carefully pull the two power cables from the fan connectors. 4. Loosens the screws that secure the fan to the module. Remove the defective fan. Figure 49. Detaching the fan from the module 5. Fastens the new fan with the screws that you removed earlier. Make sure that the fan cable is near the bottom of the module. Follow the same steps to replace the other fan. 6. Connects the fan cables to the PCB.
GigaX Series L2 Managed Switch User Guide 7.3 Simple fixes The following table lists some common problems that you may encounter when installing or using the switch, and the suggested actions to solve the problems. Table 8. Troubleshooting Problem Suggested Action LEDs SYSTEM LED does not light up after the switch is turned on. Verify if the power cord is securely connected to the switch and a wall socket/power strip. RPS LED does not light up after a redundant power supply is attached. 1.
GigaX Series L2 Managed Switch User’s Guide Problem Suggested Action Web Configuration Interface You forgot/lost your WEB Configuration Interface user ID or password. 1. If you have not changed the password from the default, try using “admin” as the user ID and bypassing password. Some pages do not display completely 1. Verify that you are using Internet Explorer v5.5 or later. Netscape is not supported. Support for Javascript® must be enabled in your browser. Support for Java® may also be required.
GigaX Series L2 Managed Switch User Guide 8 Glossary 10BASE-T A designation for the type of wiring used by Ethernet networks with a data rate of 10 Mbps. Also known as Category 3 (CAT 3) wiring. See also data rate, Ethernet. 100BASE-T A designation for the type of wiring used by Ethernet networks with a data rate of 100 Mbps. Also known as Category 5 (CAT 5) wiring. See also data rate, Ethernet. 1000BASE-T A designation for the type of wiring used by Ethernet networks with a data rate of 1000 Mbps.
GigaX Series L2 Managed Switch User’s Guide broadcast To send data to all computers on a network. Ethernet The most commonly installed computer network technology, usually using twisted pair wiring. Ethernet data rates are 10 Mbps and 100 Mbps. See also 10BASE-T, 100BASE-T, twisted pair. FTP File Transfer Protocol A program used to transfer files between computers connected to the Internet. Common uses include uploading new or updated files to a web server, and downloading files from a web server.
GigaX Series L2 Managed Switch User Guide mask See network mask. Multicast To send data to a group of network devices. Mbps Abbreviation for Megabits per second, or one million bits per second. Network data rates are often expressed in Mbps. Monitor Also called “Roving Analysis”, allow you to attach a network analyzer to one port and use it to monitor the traffics of other ports on the switch.
GigaX Series L2 Managed Switch User’s Guide ping Packet Internet (or Inter-Network) Groper A program used to verify whether the host associated with an IP address is online. It can also be used to reveal the IP address for a given domain name. port A physical access point to a device such as a computer or router, through which data flows into and out of the device. protocol A set of rules governing the transmission of data.
GigaX Series L2 Managed Switch User Guide SNMP Simple Network Management Protocol The TCP/IP protocol used for network management. STP Spanning Tree Protocol The bridge protocol to avoid packet looping in a complicate network. subnet A subnet is a portion of a network. The subnet is distinguished from the larger network by a subnet mask which selects some of the computers of the network and excludes all others.
GigaX Series L2 Managed Switch User’s Guide Telnet/SSH An interactive, character-based program used to access a remote computer. While HTTP (the web protocol) and FTP only allow you to download files from a remote computer, Telnet / SSH allows you to log into and use a computer from a remote location. TFTP Trivial File Transfer Protocol A protocol for file transfers, TFTP is easier to use than File Transfer Protocol (FTP) but not as capable or secure.
GigaX Series L2 Managed Switch User Guide upstream The direction of data transmission from the user to the Internet. VLAN Virtual Local Area Network WAN Wide Area Network Any network spread over a large geographical area, such as a country or continent. With respect to the SL-1000, WAN refers to the Internet.