Motherboard P5M2-M Series
E2777 First Edition September 2006 Copyright © 2006 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Notices.................................................................................................vii Safety information..............................................................................viii About this guide................................................................................... ix Typography........................................................................................... x P5M2-M Series specifications summary...............................................
Contents 2.7 Connectors.......................................................................... 2-23 2.7.1 Rear panel connectors........................................... 2-23 2.7.2 Internal connectors................................................ 2-24 Chapter 3: Powering up 3.1 Starting up for the first time................................................. 3-1 3.2 Powering off the computer.................................................... 3-2 3.2.1 Using the OS shut down function...........
Contents 4.4.3 Remote Access Configuration................................ 4-20 4.4.4 Trusted Computing................................................ 4-21 4.4.5 CPU Configuration.................................................. 4-22 4.4.6 Chipset Configuration............................................ 4-23 4.4.7 Onboard Devices Configuration.............................. 4-25 4.4.8 PCI PnP................................................................... 4-26 4.
5.4. 5.3.5 Checking the drives for data consistenccy............ 5-31 5.3.6 Deleting a RAID configuration................................ 5-34 5.3.7 Selecting the boot drive from a RAID set.............. 5-35 5.3.8 Enabling the WriteCache........................................ 5-36 Global Array Manager........................................................... 5-36 Chapter 6: Driver installation 6.1 6.2 6.3 6.4 vi RAID driver installation......................................................
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Safety information Electrical safety • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. • When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
About this guide This user guide contains the information you need when installing and configuring the motherboard. How this guide is organized This manual contains the following parts: • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technology it supports. • Chapter 2: Hardware information This chapter lists the hardware setup procedures that you have to perform when installing system components.
Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
P5M2-M Series specifications summary CPU LGA775 socket for Intel® Pentium®4/processor Compatible with Intel® PCG 06/05B/05A and 04B/04A and the latest Intel® dual-core processor Supports Intel® Enhanced Memory 64 Technology (EM64T) Supports Enhanced Intel SpeedStep® Technology (EIST) Supports Intel® Hyper-Threading Technology Chipset NorthBridge: Intel® Mukilteo-2 SouthBridge: Intel® ICH7R Front Side Bus 1066/800/533 MHz Memory Dual-channel memory architecture 4 x 240-pin DIMM
P5M2-M Series specifications summary Rear panel 1 x PS/2 keyboard port (purple) 1 x PS/2 mouse port (green) 2 x USB 2.
This chapter describes the motherboard features and the new technologies it supports.
Chapter summary 1 1.1 Welcome!............................................................................... 1-1 1.2 Package contents.................................................................. 1-1 1.3 Special features.....................................................................
1.1 Welcome! Thank you for buying an ASUS® P5M2-M Series motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard, and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items.
1.3 Special features 1.3.1 Product highlights Latest processor technology The motherboard comes with a 775-pin surface mount Land Grid Array (LGA) socket designed for the Intel® Pentium® 4 processor in the 775-land package. The motherboard supports the Intel® Pentium® 4 processor with 1066/800 MHz Front Side Bus (FSB). The motherboard also supports the Intel® Hyper‑Threading Technology and is fully compatible with Intel® O6, 05B/05A or 04B/04A processors. See page 2-6 for details.
Gigabit LAN solution The motherboard comes with dual Gigabit LAN controllers and ports to provide a total solution for your networking needs. The onboard Broadcom® BCM5721 Gigabit LAN controllers use the PCI Express interface and could achieve network throughput close to Gigabit bandwidth. See page 2-23 for details. Serial ATA II technology The motherboard supports the Serial ATA II technology through the Serial ATA interfaces controlled by the Intel® ICH7R.
1.3.2 Innovative ASUS features CrashFree BIOS 2 This feature allows you to restore the original BIOS data from the support CD in case when the BIOS codes and data are corrupted. This protection eliminates the need to buy a replacement ROM chip. See page 4-5 for details. ASUS MyLogo2™ This new feature present in the motherboard allows you to personalize and add style to your system with customizable boot logos. See page 4-32 for details.
This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard.
Chapter summary 2 2.1 Before you proceed............................................................... 2-1 2.2 Motherboard overview........................................................... 2-2 2.3 Central Processing Unit (CPU)............................................... 2-6 2.4 System memory................................................................... 2-13 2.5 Expansion slots.................................................................... 2-15 2.6 Jumpers........................
2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them.
2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an SSI EEB 3.5 compliant chassis. Make sure to unplug the power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage to the motherboard components. 2.2.
2.2.3 Motherboard layout 24.5cm (9.
2.2.4 Layout contents Slots/Sockets Page 1. CPU socket 2-6 2. DDR2 DIMM slots 2-13 3. PCI/PCI Express slots 2-17 Jumpers Page 1. Clear RTC RAM (CLRTC1) 2-18 2. CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) 2-19 3. USB device wake-up (3-pin USBPW12, USBPW34) 2-19 4. Keyboard/Mouse power (3-pin KBPWR1) 2-20 5. VGA controller setting (3-pin VGA_EN1) 2-20 6. Gigabit LAN controller setting (3-pin LAN_EN1; LAN_EN2) 2-21 7. RAID controller selection (3-pin RAID_SEL1) 2-21 8.
Internal connectors Page 1. Floppy disk drive connector (34-1 pin FLOPPY1) 2-24 2. ICH7R primary IDE connectors (40-1 pin PRI_IDE1) 2-25 3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) 2-26 4. Hard disk activity LED connector (4-pin HDLED1) 2-27 5. USB connector (10-1 pin USB34) 2-27 6. Serial port connector (10-1 pin COM2) 2-28 7. CPU and system fan connectors (3-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2) 2-28 8. Backplane SMBus connector (6-1 pin BPSMB1) 2-29 9.
2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA775 socket designed for the Intel® Pentium® 4 in the 775-land package. 2.3.1 • Upon purchase of the motherboard, make sure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS shoulders the repair cost only if the damage is shipment/ transit-related.
2. Press the load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. Retention tab A PnP cap Load lever B This side of the socket box should face you. To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. 3. Lift the load lever in the direction of the arrow to a 135º angle. 4.
The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! 6. Close the load plate (A), then push the load lever (B) until it snaps into the retention tab. A B The motherboard supports Intel® Pentium® 4 LGA775 processors with the Intel® Enhanced Memory 64 Technology (EM64T), Enhanced Intel SpeedStep® Technology (EIST), and Hyper-Threading Technology.
2.3.2 Installing the CPU heatsink and fan The Intel® Pentium® 4 LGA775 processor requires a specially designed heatsink and fan assembly to ensure optimum thermal condition and performance. • When you buy a boxed Intel® Pentium® 4 processor, the package includes the CPU fan and heatsink assembly. • Your Intel® Pentium® 4 LGA775 heatsink and fan assembly comes in a push-pin design and requires no tool to install.
2. 3. Push down two fasteners at a time in a diagonal sequence to secure the heatsink and fan assembly in place. A B B A B A A B Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1/CPU_FAN2. FAN_PWM FAN_PWM P5M2-M CPU Fan Connectors GND FANPWR2 CPU_FAN2 ® 2-10 FANPWR2 GND P5M2-M CPU_FAN1 • Do not forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector.
2.3.3 Uninstalling the CPU heatsink and fan To uninstall the CPU heatsink and fan: 1. Disconnect the CPU fan cable from the connector on the motherboard. 2. Rotate each fastener counterclockwise. 3. Pull up two fasteners at a time in a diagonal sequence to disengage the heatsink and fan assembly from the motherboard. 4. A B B A B A A B Carefully remove the heatsink and fan assembly from the motherboard.
5. Rotate each fastener clockwise to ensure correct orientation when reinstalling. Narrow end of the groove The narrow end of the groove should point outward after resetting. (The photo shows the groove shaded for emphasis.) Refer to the documentation in the boxed or stand-alone CPU fan package for detailed information on CPU fan installation.
2.4 System memory 2.4.1 Overview The motherboard comes with four Double Data Rate 2 (DDR2) Dual Inline Memory Modules (DIMM) sockets. A DDR2 module has the same physical dimensions as a DDR DIMM but has a 240-pin footprint compared to the 184-pin DDR DIMM. DDR2 DIMMs are notched differently to prevent installation on a DDR DIMM socket. P5M2-M The figure illustrates the location of the DDR2 DIMM sockets: 128 Pins 112 Pins DIMM_A1 DIMM_A2 ® DIMM_B1 DIMM_B2 P5M2-M 240-pin DDR2 DIMM Sockets 2.4.
2.4.3 Installing a DIMM Unplug the power supply before adding or removing DIMMs or other system components. Failure to do so can cause severe damage to both the motherboard and the components. 2 To install a DIMM: 1. Unlock a DIMM socket by pressing the retaining clips outward. 2. Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket. 3.
2.5 Expansion slots In the future, you may need to install expansion cards. The following sub‑sections describe the slots and the expansion cards that they support. Make sure to unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage to the motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1.
2.5.
2.5.4 PCI slot The PCI slot supports cards such as a LAN card, SCSI card, USB card, and other cards that comply with PCI specifications. The figure shows a LAN card installed on a PCI slot. 2.5.5 PCI Express x8 slot This motherboard supports PCI Express x8 cards that comply with the PCI Express specifications.
2.6 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. Turn OFF the computer and unplug the power cord. 2. Remove the onboard battery. 3. Move the jumper cap from pins 1-2 (default) to pins 2-3.
2. CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) These jumpers allow you to connect either a 3-pin or a 4-pin fan cable plug to the CPU fan connectors (CPU_FAN1, CPU_FAN2). Set these jumpers to pins 1-2 if you are using a 3-pin fan cable plug, or to pins 2‑3 if you are using a 4-pin plug. FM_CPU1 P5M2-M 1 2 3-pin fan (Default) 4-pin fan FM_CPU2 ® 1 2 P5M2-M FM CPU Setting 3.
4. Keyboard/Mouse power (3-pin KBPWR1) This jumper allows you to enable or disable the keyboard/mouse wake-up feature. Set this jumper to pins 2-3 (+5VSB) to wake up the computer when you press a key on the keyboard (the default is the Space Bar) or use the mouse. This feature requires an ATX power supply that can supply at least 1A on the +5VSB lead, and a corresponding setting in the BIOS. KBPWR1 P5M2-M 1 2 2 3 +5V (Default) +5VSB ® P5M2-M Keyboard Power Setting 5.
Gigabit LAN controller setting [3-pin LAN_EN1, LAN_EN2 (for P5M2-M model only )] These jumpers allow you to enable or disable the onboard Broadcom® BCM5721 Gigabit LAN1 or LAN2 controller. Set to pins 1-2 to activate the Gigabit LAN controller. P5M2-M 6.
8. Force BIOS recovery setting (3-pin RECOVERY1) This jumper allows you to quickly update or recover the BIOS when it gets corrupted. To update the BIOS: Prepare a floppy disk that contains the latest BIOS for the motherboard (xxxx-xxx.ROM) and the AFUDOS.EXE utility. 2. Set the jumper to pins 2-3. 3. Insert the floppy disk then turn on the system to update the BIOS. 4. Shut down the system. 5. Set the jumper back to pins 1-2. 6. Turn on the system. P5M2-M 1.
2.7 Connectors 2.7.1 Rear panel connectors 1 8 2 7 6 5 4 3 Rear Panel of P5M2-M 1 8 2 7 6 5 Rear Panel of P5M2-M/C 3 1. PS/2 mouse port (green). This port is for a PS/2 mouse. 2. Parallel port. This 25-pin port connects a parallel printer, a scanner, or other devices. 3. Gigabit LAN1 (RJ-45) port. This ports allow Gigabit connection to a Local Area Network (LAN) through a network hub. Refer to the table below for the LAN port LED indications. 4. Gigabit LAN2 (RJ-45) port.
LAN port LED indications ACT/LINK LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection 2.7.2 1. SPEED LED ACT/LINK SPEED LED LED LAN port Internal connectors Floppy disk drive connector (34-1 pin FLOPPY1) This connector is for the provided Floppy Disk Drive (FDD) signal cable.
2. ICH7R primary IDE connector (40-1 pin PRI_IDE1) This connector is for an Ultra DMA 100/66 signal cable. The Ultra DMA 100/66 signal cable has three connectors: a blue connector for the primary IDE connector on the motherboard, a black connector for an Ultra DMA 100/66 IDE slave device (optical drive/hard disk drive), and a gray connector for an Ultra DMA 100/66 IDE master device (hard disk drive).
3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) These connectors are for the Serial ATA signal cables for Serial ATA hard disk drives. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 0+1, and RAID 5 configuration using the Intel® Matrix Storage Technology or RAID 0, RAID 1 and RAID 0+1 configuration using the LSI MegaRAID® utility embedded in the Intel® ICH7R Southbridge.
4. Hard disk activity LED connector (4-pin HDLED1) HDLED1 P5M2-M This connector supplies power to the hard disk activity LED. The read or write activities of any device connected to the SCSI connectors or the SATA connectors cause this LED to light up. NC ADD_IN_CARD_ACT# ADD_IN_CARD_ACT# NC 1 ® P5M2-M SCSI/SATA Card Activity LED Connector 5. USB connector (10-1 pin USB34) USB+5V USB_P4USB_P4+ GND NC P5M2-M This connector is for USB 2.0 ports.
6. Serial port connector (10-1 pin COM2) This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis. The serial port module is purchased separately. P5M2-M COM2 PIN 1 ® P5M2-M Serial Port2 (COM2) Connector 7. CPU and system fan connectors (3-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2) The fan connectors support cooling fans of 350 mA ~ 740 mA (8.88 W max.) or a total of 2.1 A ~ 4.
8. Backplane SMBus connector (6-1 pin BPSMB1) P5M2-M This connector allows you to connect SMBus (System Management Bus) devices. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface. 1 BPSMB1 9. GND I2C_DATA +5V P5M2-M SMBus Connector FAN_DC1 I2C_CLK ® Power supply SMBus connector (5-pin PSUSMB1) This connector is for the power supply SMB cable, if your power supply supports the SMBus function. ® +3.
10. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V2) These connectors are for SSI power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • Use of an SSI 12 V Specification 2.0-compliant power supply unit (PSU) that provides a minimum power of 450 W is recommended for a fully-configured system.
11. Auxiliary panel connector (20-pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. • Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. • LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel.
12. System panel connector (20-pin PANEL1) This connector supports several chassis-mounted functions. System power LED (Green 3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. • Message LED (Brown 2-pin MLED) This connector is for the message LED cable that connects to the front message LED.
This chapter describes the power up sequence, the vocal POST messages, and ways of shutting down the system.
Chapter summary 3 3.1 Starting up for the first time................................................. 3-1 3.2 Powering off the computer....................................................
3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 2. Be sure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis. 4. Connect the power cord to a power outlet that is equipped with a surge protector. 5. Turn on the devices in the following order: a. Monitor b. External SCSI devices (starting with the last device on the chain) c. 6.
3.2 Powering off the computer 3.2.1 Using the OS shut down function If you are using Windows® Server 2000: 1. Click the Start button then click Shut Down... 2. Make sure that the Shut Down option button is selected, then click the OK button to shut down the computer. 3. The power supply should turn off after Windows® shuts down. If you are using Windows® Server 2003: 1. Click the Start button then select Turn Off Computer. 2. Click the Turn Off button to shut down the computer. 3.
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
Chapter summary 4 4.1 Managing and updating your BIOS......................................... 4-1 4.2 BIOS setup program............................................................. 4-10 4.3 Main menu............................................................................ 4-13 4.4 Advanced menu................................................................... 4-18 4.5 Power Configuration............................................................ 4-27 4.6 Boot menu........................
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup. 1. ASUS AFUDOS (Updates the BIOS in DOS mode using a bootable floppy disk.) 2. ASUS CrashFree BIOS 2 (Updates the BIOS using a bootable floppy disk or the motherboard support CD when the BIOS file fails or gets corrupted.) 3. ASUS Update (Updates the BIOS in Windows® environment.) Refer to the corresponding sections for details on these utilities.
4.1.2 AFUDOS utility The AFUDOS utility allows you to update the BIOS file in DOS environment using a bootable floppy disk with the updated BIOS file. This utility also allows you to copy the current BIOS file that you can use as backup when the BIOS fails or gets corrupted during the updating process. Copying the current BIOS To copy the current BIOS file using the AFUDOS utility: • Make sure that the floppy disk is not write-protected and has at least 1024 KB free space to save the file.
Updating the BIOS file To update the BIOS file using the AFUDOS utility: 1. Visit the ASUS website (www.asus.com) and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable floppy disk. Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt. 2. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier. 3.
5. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive. A:\>afudos /iP5M2-M.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file ....... done Reading flash ...... done Advance Check ...... Erasing flash ...... done Writing flash ...... done Verifying flash ....
4.1.3 ASUS CrashFree BIOS 2 utility The ASUS CrashFree BIOS 2 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using the motherboard support CD or the floppy disk that contains the updated BIOS file. • Prepare the motherboard support CD or the floppy disk containing the updated motherboard BIOS before using this utility.
Recovering the BIOS from the support CD To recover the BIOS from the support CD: 1. Remove any floppy disk from the floppy disk drive, then turn on the system. 2. Insert the support CD to the optical drive. 3. The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file. Bad BIOS checksum. Starting BIOS recovery... Checking for floppy...
4.1.4 ASUS Update utility The ASUS Update is a utility that allows you to manage, save, and update the motherboard BIOS in Windows® environment. The ASUS Update utility allows you to: • Save the current BIOS file • Download the latest BIOS file from the Internet • Update the BIOS from an updated BIOS file • Update the BIOS directly from the Internet, and • View the BIOS version information. This utility is available in the support CD that comes with the motherboard package.
Updating the BIOS through the Internet To update the BIOS through the Internet: 4- 1. Launch the ASUS Update utility from the Windows® desktop by clicking Start > Programs > ASUS > ASUSUpdate > ASUSUpdate. The ASUS Update main window appears. 2. Select Update BIOS from the Internet option from the drop‑down menu, then click Next. 3. Select the ASUS FTP site nearest you to avoid network traffic, or click Auto Select. Click Next.
4. From the FTP site, select the BIOS version that you wish to download. Click Next. 5. Follow the screen instructions to complete the update process. The ASUS Update utility is capable of updating itself through the Internet. Always update the utility to avail all its features. Updating the BIOS through a BIOS file To update the BIOS through a BIOS file: 1. Launch the ASUS Update utility from the Windows® desktop by clicking Start > Programs > ASUS > ASUSUpdate > ASUSUpdate.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section “4.1 Managing and updating your BIOS”. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup”. This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Menu bar Configuration fields General help BIOS SETUP UTILITY Main Advanced Power Boot Exit System Time System Date Legacy Diskette A [11:10:19] [Tue 01/01/2002] [1.44M, 3.5 in] Primary IDE Master Primary IDE Slave Third IDE Master Third IDE Slave Fourth IDE Master Fourth IDE Slave IDE Configuration : : : : : : [Not [Not [Not [Not [Not [Not Detected] Detected] Detected] Detected] Detected] Detected] System Information Use [ENTER].
4.2.4 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items. 4.2.5 BIOS SETUP UTILITY Main Advanced Power Boot Exit System Time [11:10:19] System Date [Tue 01/01/2002] Legacy Diskette A [1.44M, 3.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information. Refer to section “4.2.1 BIOS menu screen” for information on the menu screen items and how to navigate through them.
4.3.4 Primary, Third, Fourth IDE Master/Slave The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press to display the IDE device information. BIOS SETUP UTILITY Main Primary IDE Master Device : Not Detected Select the type of device connected to the system.
PIO Mode [Auto] Selects the PIO mode. Configuration options: [Auto] [0] [1] [2] [3] [4] DMA Mode [Auto] Selects the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] SMART Monitoring [Auto] Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled] 32Bit Data Transfer [Enabled] Enables or disables 32-bit data transfer. Configuration options: [Disabled] [Enabled] 4.3.
Onboard IDE Operate Mode [Enhanced Mode] Allows selection of the onboard IDE operation mode depending on the installed operating system (OS). Set to [Enhanced] if you are using native OS, e.g. Windows® 2000/XP. Set to [Compatible] if you are using legacy OS, e.g. Windows ME/98/NT, MS-DOS. Configuration options: [Disabled] [Compatible] [Enhanced] Set the item Configure SATA as to [RAID] if you want to use or configure the SATA connectors under SuSE Linux Enterprise Server 9.
4.3.6 System Information This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu. BIOS SETUP UTILITY Main AMIBIOS Version Build Date : 0115 : 08/14/06 Processor Type Speed Count : Genuine Intel(R) CPU 2.80GHz : 2800 MHz : 2 System Memory Usable Size : 1024MB +F1 F10 ESC Select Screen Select Item Change Option General Help Save and Exit Exit AMI BIOS Displays the auto-detected BIOS information.
4.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Main Advanced BIOS SETUP UTILITY Power Boot Exit Configure the MultiProcessor Table. USB Configuration MPS Configuration Remote Access Configuration Trusted Computing CPU Configuration Chipset Onboard Devices Configuration PCIPnP +F1 F10 ESC 4.4.
When USB Function set to 2 USB Ports or 4 USB Ports, the following items appear. Legacy USB Support [Enabled] Allows you to enable or disable support for legacy USB. The AUTO option disables legacy support if there is no USB device connected. Configuration options: [AUTO] [2 USB Ports] [4 USB Ports] USB 2.0 Controller [Enabled] Allows you to enable or disable the USB 2.0 controller. Configuration options: [Enabled] [Disabled] USB2.0 Controller mode [HiSpeed] Allows you to select the USB2.0 controller mode.
4.4.3 Remote Access Configuration The items in this menu allows you to configure the Remote Access features. Select an item then press to display the configuration options.
Terminal Type [ANSI] Allows you to select the target terminal type. Configuration options: [ANSI] [VT100] [VT-UTF8] VT-UTF8 Combo Key Support [Enabled] Allows you to enable or disable VT-UTF8 Combination Key Support for ANSI/VT100 terminals. Configuration options: [Enabled] [Disabled] Media Type [Serial] Allows you to select the media for console redirection. Configuration options: [Serial] [LAN] [Serial + LAN] 4.4.
4.4.5 CPU Configuration The items in this menu show the CPU-related information that the BIOS automatically detects. Advanced BIOS SETUP UTILITY Configure Advanced CPU settings Manufacturer: Brand String: Frequency : FSB Speed : Cache L1 : Cache L2 : Cache L3 : Sets the ratio between CPU Core Clock and the FSB Frequency. NOTE: If an invalid ratio is set in CMOS then actual and setpoint values may differ. Intel Genuine Intel(R) CPU 2.
The Hyper-Threading Technology item appears only when you installed an Intel® Pentium® 4 CPU that supports the Hyper-Threading Technology. Hyper-Threading is not supported when you installed a dual-core CPU. Hyper-Threading Technology [Enabled] Allows you to enable or disable the processor Hyper-Threading Technology. Configuration options: [Disabled] [Enabled] 4.4.6 Chipset Configuration The Chipset Configuration menu allows you to change the advanced chipset settings.
DRAM RAS# to CAS# Delay [4 Clocks] Controls the latency between the DDR SDRAM active command and the read/write command. Configuration options: [2 Clocks] [3 Clocks] [4 Clocks] [5 Clocks] DRAM RAS# Activate to Precharge Delay [15 DRAM Clocks] Configuration options: [1 Clocks] [2 Clocks] ~ [15 Clocks] DRAM Write Recovery Time [4 Clocks] Configuration options: [2 Clocks] [3 Clocks] [4 Clocks] [5 Clocks] Spread Spectrum [Disabled] Allows you to enable or disable the spread spectrum.
4.4.7 Onboard Devices Configuration The Onboard Devices Configuration menu allows you to change the onboard devices settings. Select an item then press to display the submenu.
4.4.8 PCI PnP The PCI PnP menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting IRQ and DMA channel resources for either PCI/PnP or legacy ISA devices, and setting the memory size block for legacy ISA devices. Take caution when changing the settings of the PCI PnP menu items. Incorrect field values can cause the system to malfunction. Advanced PCI/PnP Settings WARNING: Setting wrong values in below sections may cause system to malfunction.
4.5 Power Configuration The Power Configuration menu items allow you to change the settings for the ACPI and Advanced Power Management (APM) features. Select an item then press to display the configuration options. Main Advanced BIOS SETUP UTILITY Power Boot Exit ACPI APIC Support [Enabled] APM Configuration Include ACPI APIC table pointer to RSDT pointer list.
whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State] Resume On By RTC Alarm [Disabled] Allows you to enable or disable RTC to generate a wake event. When this item is set to [Enabled], the items RTC Alarm Date, RTC Alarm Hour, RTC Alarm Minute, and RTC Alarm Second appear with set values. Configuration options: [Disabled] [Enabled] The following items appear only when the Resume On By RTC Alarm item is set to Enabled.
4.5.2 Hardware Monitor Hardware Monitor CPU Temperature MB1 Temperature MB2 Temperature CPU Fan1 Speed CPU Fan2 Speed Front Fan1 Speed Front Fan2 Speed Rear Fan1 Speed Rear Fan2 Speed Smart Fan Control CPU Target Temperature MB Target Temperature VCORE Voltage 3.3V Voltage 5V Voltage CPU1 Temperature [49ºC/120ºF] [47ºC/114ºF] [47ºC/114ºF] [3884RPM] [N/A] [N/A] [N/A] [N/A] [N/A] [Smart Fan] [055] [050] [ 1.320V] [ 3.345V] [ 5.094V] Use the arrow down key to display additional items.
CPU Temperature [XXX] MB1 Temperature [XXX] Displays the detected CPU and system threshold temperature when the Smart Fan Control is enabled. VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage The onboard hardware monitor automatically detects the voltage outputs through the onboard voltage regulators. 4.6 Boot menu The Boot menu items allow you to change the system boot options. Select an item then press to display the sub-menu.
4.6.1 Boot Device Priority BIOS SETUP UTILITY Boot Boot Device Priority 1st Boot Device 2nd Boot Device 3rd Boot Device [1st FLOPPY Drive] [Network: MBA v7.7.5] [Network: MBA v7.7.5] 1st Boot Device [1st FLOPPY Drive] 2nd Boot Device [Network: MBA v7.7.5] 3rd Boot Device [Network: MBA v7.7.5] These items specify the boot device priority sequence from the available devices. Configuration options: [xxxxx Drive] [Disabled] 4.6.
4.6.3 Boot Settings Configuration BIOS SETUP UTILITY Boot Boot Settings Configuration Quick Boot Full Screen Logo AddOn ROM Display Mode Bootup Num-Lock PS/2 Mouse Support Wait For ‘F1’ If Error Hit ‘DEL’ Message Display Interrupt 19 Capture [Enabled] [Enabled] [Force BIOS] [On] [Auto] [Enabled] [Enabled] [Disabled] Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system.
Hit ‘DEL’ Message Display [Enabled] When set to Enabled, the system displays the message “Press DEL to run Setup” during POST. Configuration options: [Disabled] [Enabled] Interrupt 19 Capture [Disabled] When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Configuration options: [Disabled] [Enabled] 4.6.4 Security The Security menu items allow you to change the system security settings. Select an item then press to display the configuration options.
To clear the supervisor password, select the Change Supervisor Password then press . The message “Password Uninstalled” appears. If you forget your BIOS password, you can clear clear it by erasing the CMOS Real Time Clock (RTC) RAM. See section “2.6 Jumpers” for information on how to erase the RTC RAM. After you have set a supervisor password, the other items appear to allow you to change other security settings.
2. On the password box that appears, type a password composed of at least six letters and/or numbers, then press . 3. Confirm the password when prompted. The message “Password Installed” appears after you set your password successfully. To change the user password, follow the same steps as in setting a user password. Clear User Password Select this item to clear the user password. Password Check [Setup] When set to [Setup], BIOS checks for user password when accessing the Setup utility.
4.7 Exit menu The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items. Main Advanced Power BIOS SETUP UTILITY Boot Exit Exit Options Exit & Save Changes Exit & Discard Changes Discard Changes Load Setup Defaults Exit system setup after saving the changes. F10 key can be used for this operation.
When a confirmation window appears, select [OK] then press to discard the changes, and load the previously saved settings. If you wish to cancel the command, select [Cancel] then press to return to the Exit menu. Load Setup Defaults Select this option then press to load the optimized settings for each of the Setup menu items. When a confirmation window appears, select [OK] then press to load the default settings.
This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities.
Chapter summary 5 5.1 RAID configurations............................................................... 5-1 5.2 Intel Matrix Storage Manager option ROM utility................... 5-3 5.3 LSI Logic Embedded SATA RAID Setup Utility..................... 5-14 5.4 Global Array Manager...........................................................
5.1 RAID configurations The server system/motherboard comes with the Intel® ICH7R and the LSI Logic Embedded SATA RAID technology built-in the Intel® ICH7R SouthBridge chipset that allows you to configure IDE and Serial ATA hard disk drives as RAID sets. The motherboard supports the following RAID configurations: 5.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks.
5.1.2 Installing Serial ATA hard disks The motherboard supports Serial ATA hard disk drives. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for a RAID configuration: 1. Install the SATA hard disks into the drive bays. 2. Connect the SATA signal cables. 3. Connect a SATA power cable to the power connector on each drive. 5.1.
5.2 Intel® Matrix Storage Manager Option ROM Utility The Intel® Matrix Storage Manager Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 0+1), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. To enter the Intel® Application Accelerator RAID Option ROM utility: 1. Install all the Serial ATA hard disk drives. 2. Turn on the system. 3. During POST, press + to display the utility main menu.
5.2.1 Creating a RAID 0 set (striped) To create a RAID 0 set: 1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears. Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ CREATE ARRAY MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow key to select the stripe size for the RAID 0 array, then press . The available stripe size values range from 8 KB to 128 KB. The default stripe size is 128 KB. TIP: We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. Key in the RAID volume capacity that you want, then press . The default value indicates the maximum allowed capacity. 8.
5.2.2 Creating a RAID 1 set (mirrored) To create a RAID 1 set: 1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears. Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ CREATE ARRAY MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume1 RAID1(Mirror) Select Disks N/A XX.
5.2.3 Creating a RAID 10 set (RAID 0+1) To create a RAID 10 set: 1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears. Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ CREATE ARRAY MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume10 RAID10(RAID0+1) Select Disks 128KB XXX.
8. Press when the Create Volume item is highlighted. This warning message appears. WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 9. Press to create the RAID volume and return to the main menu or to go back to the Create Volume menu. 5.2.4 Creating a RAID 5 set (parity) To create a RAID 5 set: 1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears.
4. When the Disks item is highlighted, press to select the hard disk drives to configure as RAID. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model Serial # Size XXXXXXXXXXXX XXXXXXXX XX.XGB XXXXXXXXXXXX XXXXXXXX XX.XGB XXXXXXXXXXXX XXXXXXXX XX.XGB XXXXXXXXXXXX XXXXXXXX XX.
5.2.5 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume, then press to display this screen. Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Level Drives Capacity Status Bootable Volume0 RAIDX(xxxxx) X XXX.
5.2.6 Resetting Disks to Non-RAID Take caution before you reset a RAID volume HDD to non-RAID. Resetting a RAID volume HDD deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID, then press to display this screen. [ RESET RAID DATA ] Resetting RAID data will remove internal RAID structures from the selected RAID disks. By removing these structures, the drive will revert back to a non-RAID disk.
5.2.8 Rebuilding the RAID This option is only for the RAID 1, RAID 5 and RAID 10 sets. Rebuilding the RAID with other non-RAID disk If any of the SATA hard disk drives included in the RAID array failed, the system displays the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array with other installed non-RAID disks. To rebuild the RAID with other non-RAID disk: 1. At the prompt, press + to enter the Intel Matrix Storage Manager RAID configuration. 2.
4. Exit the RAID configuration utility and reboot the system. 5. Select Start > Programs > Intel Matrix Storage > Intel Matrix Storage Console or click the Intel Matrix Storage Manager tray icon to load the Intel Matrix Stroage Manager utility. 6. From the View menu, select Advanced Mode to display the details of the Intel Matrix Storage Console. 7. From the Volumes view option, select RAID volume to view the rebuilding status. When finished, the status is changed to “Normal”.
5.3 LSI Logic Embedded SATA RAID Setup Utility The LSI Logic Embedded SATA RAID Setup Utility allows you to create RAID 0, RAID 1, and RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard Southbridge chip. The LSI Logic Embedded SATA RAID automatically configures a RAID 1 (Mirrored) set when the SATA is configured as RAID in the BIOS and you installed two hard disk drives without a RAID configuration.
3. The utility main window appears. Use the arrow keys to select an option from the Management Menu, then press . Refer to the Management Menu descriptions below. At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level.
Using Easy Configuration To create a RAID set using the Easy Configuration option: 1. From the utility main menu, highlight Configure, then press . 2. Use the arrow keys to select Easy Configuration, then press . 3. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drives you want to include in the RAID set, then press .
4. Select all the drives required for the RAID set, then press . The configurable array appears on screen. 5. Press , select the configurable array, then press . The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
6. Select RAID from the Logical Drive menu, then press . 7. Select the RAID level from the menu, then press . You need at least two identical hard disk drives when creating a RAID 1 set. 8. When creating a RAID 1 or a RAID 10 set, select Stripe Size from the Logical Drive menu, then press . When creating a RAID 0 set, proceed to step 10. 9. Key in the stripe size, then press . For server systems, we recommend that you use a lower array block size.
10. When finished setting the selected logical drive configuration, select Accept from the menu, then press . 11. Follow steps 5 to 10 to configure additional logical drives. 12. When prompted, save the configuration, then press to return to the Management Menu.
Using New Configuration When a RAID set is already existing, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option: 5-20 1. From the utility main menu, highlight Configure, then press . 2. Use the arrow keys to select New Configuration, then press . 3.
5.3.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, highlight Configure, then press . 2. Use the arrow keys to select View/Add Configuration, then press . 3. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports.
4. Select all the drives required for the RAID set, then press . The configurable array appears on screen. 5. Press , select the configurable array, then press . The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
6. Follow steps 6 to 7 of the Creating a RAID set: Using Easy Configuration section. 7. Select Size from the Logical Drive menu, then press . 8. Key in the desired logical drive size, then press . 9. Follow steps 8 to 12 of the Creating a RAID set: Using Easy Configuration section to add the new RAID configuration.
5.3.3 Initializing the logical drives After creating the RAID set(s), you must initialize the logical drives. You may initialize the logical drives of a RAID set(s) using the Initialize or Objects command in the Management Menu. Using the Initialize command To initialize the logical drive using the Initialize command: 5-24 1. From the Management Menu, highlight Initialize, then press . 2. The screen displays the available RAID set(s) and prompts you to select the logical drive to initialize.
3. When prompted, press the to select Yes from the Initialize? dialog box, then press . You may also press to initialize the drive without confirmation. Initializing a logical drive(s) erases all data on the drive. 4. A progress bar appears on screen. If desired, press to abort initialization.
5. When initialization is completed, press . Using the Objects command To initialize the logical drives using the Objects command: 1. 5-26 From the Management Menu, highlight Objects, then press .
2. Select Logical Drive from the Objects sub-menu, then press . 3. Select the logical drive to initialize from the Logical Drives sub‑menu, then press . 4. Select Initialize from the pop-up menu, then press to start initialization.
5-28 5. When prompted, press the to select Yes from the Initialize? dialog box, then press . You may also press to initialize the drive without confirmation. 6. A progress bar appears on screen. If desired, press to abort initialization. 7. When initialization is completed, press .
5.3.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild or Objects command in the Management Menu. Using the Rebuild command To rebuild a failed hard disk drive using the Rebuild command: 1. From the Management Menu, highlight Rebuild, then press . 2. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. Select the drive you want to rebuild, then press .
3. After selecting the drive to rebuild, press . The indicator for the selected drive now shows RBLD. 4. When prompted, press to to rebuild the drive. 5. When rebuild is complete, press any key to continue. Using the Objects command To rebuild a failed hard disk drive using the Objects command: 5-30 1. From the Management Menu, select Objects, then select Physical Drive from the menu. 2. Use the arrow keys to select the physical drive you want to rebuild, then press . 3.
5.3.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for logical drives included in a RAID 1 set. Using the Check Consistency To check data consistency using the Check Consistency command: 1.
3. When prompted, press the to select Yes from the Consistency Check dialog box, then press . You may also press to check the drive consistency. A progress bar appears on screen. 4. While checking the disk consistency, press to display the following options. • Stop - Stops the consistency check. The utility stores the percentage of disk checked. When you restart checking, it continues from the last percentage completed rather than from zero percent.
Using the Objects command To check data consistency using the Objects command: 1. From the Management Menu, select Objects, then select Logical Drive from the menu. 2. Use the arrow keys to select the logical drive you want to check, then press . 3. Select Check Consistency from the pop-up menu, then press . 4. When prompted, press to to check the drive. 5. When checking is complete, press any key to continue.
5.3.6 Deleting a RAID configuration To delete a RAID configuration: 1. From the Management Menu, select Configure > Clear Configuration, then press . 2. When prompted, press the to select Yes from the Clear Configuration? dialog box, then press . The utility clears the current array. 3. 5-34 Press any key to continue.
5.3.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. Refer to the Creating a RAID set: Using New Configuration section for details. To select the boot drive from a RAID set: 1. From the Management Menu, select Configure > Select Boot Drive, then press . 2. When prompted, press the to select the bootable logical drive from the list, then press . 3.
5.3.8 Enabling the WriteCache You may enable the RAID controller’s WriteCache option to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. To enable WriteCache: 1. From the Management Menu, select Objects > Adapter, then press to display the adapter properties. 2. Select WriteCache, then press to turn the option On (enabled). 3.
This chapter provides instructions for installing the necessary drivers for different system components.
Chapter summary 6 6.1 RAID driver installation........................................................... 6-1 6.2 LAN driver installation......................................................... 6-11 6.3 VGA driver installation......................................................... 6-13 6.4 Management applications and utilities installation...............
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk You may have to use another system to create the RAID driver disk from the system/motherboard support CD or from the Internet.
For systems with Red Hat® Enterprise versions that are not listed in the Makedisk menu, explore the support CD and copy the RAID driver disk from the following path: \Drivers\ICH7R\LSI\Linux. 6.1.2 Installing the RAID controller driver Windows ® 2000/2003 Server OS During Windows® 2000/2003 Server OS installation To install the RAID controller driver when installing Windows® 2000/2003 Server OS: 6- 1. Boot the computer using the Windows® 2000/2003 Server installation CD.
4. Insert the RAID driver disk you created earlier to the floppy disk drive, then press . 5. Select the RAID controller driver from the list, then press . LSI Logic SATA RAID Select “LSI Logic Embedded SATA RAID” for Windows 2000 or 32bit Windows 2003 Server OS from the list, then press . For 64bit Windows 2003 Server OS, please select “LSI Logic Embedded SATA RAID ( Intel IA32E )” item.
Intel Matrix Storage Select “Intel(R) 82801GR/GH SATA RAID Controller (Desktop ICH7RDH)” for Intel Matrix Storage RAID mode from the list, then press . If you configured SATA as AHCI Mode in the BIOS setup utility of IDE Configuration, first install the Intel SATA AHCI Driver during windows setup. Then, select the “Intel(R) 82801GR/GH SATA AHCI Controller (Desktop ICH7RDH)” from the list. Refer to section “6.1.1 Creating a RAID driver disk” to create the Intel SATA Driver for windows system. 6- 6.
To an existing Windows® 2000/2003 Server OS To install the RAID controller driver on an existing Windows® 2000/2003 Server OS: 1. Restart the computer, then log in with Administrator privileges. 2. Windows® automatically detects the RAID controller and displays a New Hardware Found window. Click Cancel. 3. Right-click the My Computer icon on the Windows® desktop , then select Properties from the menu. 4.
To verify the RAID controller driver installation: 6- 1. Right-click the My Computer icon on the Windows® desktop , then select Properties from the menu. 2. Click the Hardware tab, then click the Device Manager button. 3. Click the “+” sign before the item SCSI and RAID controllers. The LSI Logic Embedded SATA RAID or Intel® 8201 GR/GH SATA RAID items should appear. 4. Right-click the RAID controller driver item, then select Properties from the menu. 5.
Red Hat ® Enterprise ver. 3.0 To install the Intel® ICH7R LSI Logic Embedded SATA RAID controller driver when installing Red Hat® Enterprise ver. 3.0 operating system: 1. Boot the system from the Red Hat® Installation CD. 2. At the boot:, type linux dd , then press .
6- 3. Select Yes using the key when asked if you have the driver disk. Press 4. Select fd0 using the key when asked to select the driver disk source. Press to move the cursor to OK, then press .
5. When prompted, insert the Red Hat® Enterprise ver. 3.0 RAID driver disk to the floppy disk drive, select OK, then press . The drivers for the RAID controller are installed to the system. 6. When asked if you will load additional RAID controller drivers, select Yes, then install the additional RAID controller drivers. 7. Follow screen instructions to continue the OS installation.
SuSE Linux To install the RAID controller driver when installing SuSE Linux OS: 1. Boot the system from the SuSE Installation CD. 2. Select Installation from the Boot Options menu, then press . 3. A message instructs you to prepare the RAID driver disk. Press . For SuSE Linux Enterprise Server 9.0 SP1 operating system, do not use OS bundled driver, otherwise your computer may become unstable due to OS limitation.
4. When prompted, insert the RAID driver disk to the floppy disk drive, then press . 5. When prompted, select the floppy disk drive (fd0) as the driver update medium, select OK, then press . The drivers for the RAID controller are installed to the system.
6.2 LAN driver installation This section provides instructions on how to install the Broadcom® Gigabit LAN controller drivers. 6.2.1 Windows ® 2000/2003 Server To install the Broadcom® Gigabit LAN controller driver on a Windows® 2000/2003 Server OS: 1. Restart the computer, then log on with Administrator privileges. 2. Insert the motherboard/system support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer. 3.
4. Click Next when the InstallShield Wizard window appears. Follow screen instructions to continue installation. 6.2.2 Red Hat ® Enterprise ver. 3.0 Follow these instructions when installing the Broadcom® Gigabit LAN controller base driver for the Red Hat® Enterprise ver. 3.0 operating system. Building the driver from the TAR file Install first the Kernel Development tools before building the driver from the TAR file. To build the driver from the TAR file: 1.
6.3 VGA driver installation This section provides instructions on how to install the XGI Graphics driver. 6.3.1 Windows ® 2000 Server You need to manually install the XGI Graphics driver on a Windows® 2000 Server operating system. To install the XGI Graphicsdriver: 1. Restart the computer, then log on with Administrator privileges. 2. Insert the motherboard/system support CD to the optical drive. The support CD automatically displays the Drivers menu if Autorun is enabled in your computer.
6.3.2 Windows ® 2003 Server 6.3.3 Red Hat ® Enterprise ver. 3.0 The Windows® 2003 Server operating system automatically recognizes the XGI Graphics driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA. The Red Hat® Enterprise ver. 3.0 operating system automatically recognizes the XGI Graphics driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA.
6.4 Management applications and utilities installation The support CD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support CD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.4.1 Running the support CD Place the support CD to the optical drive.
6.4.3 Management Software menu The Management Software menu displays the available network and server monitoring application. Click on an item to install. 6.4.4 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click on an item to install.
6.4.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.