Motherboard P10S-M
E14508 Revised Edition V4 July 2018 Copyright © 2018 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Notices ....................................................................................................................... vii Federal Communications Commission Statement..........................................vii REACH ...................................................................................................... viii Australia statement notice.............................................................................. viii Safety information......................................
Contents 2.5 Expansion slots......................................................................................... 2-15 2.5.1 Installing an expansion card...................................................... 2-15 2.5.2 Configuring an expansion card.................................................. 2-15 2.5.3 Interrupt assignments................................................................ 2-16 2.5.4 PCI Express x8 slot (x8 link)...................................................... 2-16 2.
Contents 4.3 4.4 Main menu................................................................................................... 4-9 4.3.1 System Date [Day xx/xx/xxxx]...................................................... 4-9 4.3.2 System Time [xx:xx:xx]................................................................ 4-9 Advanced menu........................................................................................ 4-10 4.4.1 Trusted Computing.......................................................
Contents 5.3 Intel® Rapid Storage Technology enterprise (Windows)....................... 5-12 5.3.1 Creating a RAID set................................................................... 5-13 5.3.2 Changing a Volume Type.......................................................... 5-15 5.3.3 Deleting a volume...................................................................... 5-16 5.3.4 Preferences................................................................................ 5-17 Chapter 6: 6.
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
REACH Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we publish the chemical substances in our products at ASUS REACH website at http://csr.asus.com/english/REACH.htm. Australia statement notice From 1 January 2012 updated warranties apply to all ASUS products, consistent with the Australian Consumer Law. For the latest product warranty details please visit https://www.asus. com/support.
Safety information Electrical safety • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. • When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
Conventions used in this guide To ensure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
P10S-M Specifications Summary Processor Support / System Bus 1 x Socket LGA1151 Intel® Xeon® processor E3-1200 v6 product family Intel® Xeon® processor E3-1200 v5 product family Intel® Core™ i3 processors Intel® Pentium™ processors Intel® Celeron™ processors Intel® C232 Chipset Core Logic Form Factor Micro ATX, 9.6 in. x 9.6 in.
Networking LAN Graphic VGA TPM Header PSU Connector Management Header Onboard I/O Connectors PS/2 KB/Mouse Software ASWM Enterprise Out of Band Remote Management Optional ASMB8-iKVM for KVM-over-Internet Fan Header Chassis Intruder Front LAN LED VGA Header M.2 Connector External Serial Port External USB Port VGA Port RJ-45 Management Solution Onboard header for optional management card 1 x USB 3.0 pin header (up to 2 devices) 1 x USB 2.0 pin header (up to 2 devices) 1 x USB 3.
Chapter 1: Product Introduction
1.1 Welcome! Thank you for buying an ASUS® P10S-M motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items.
1.3 Serial number label Before requesting support from the ASUS Technical Support team, you must take note of the motherboard's serial number containing 12 characters xxS2xxxxxxxx shown as the figure below. With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems. P10S-M xxS2xxxxxxxx 1.4 Special features 1.4.
PCI Express 3.0 PCI Express 3.0 (PCIe 3.0) is the PCI Express bus standard that provides twice the performance and speed of PCIe 2.0. It provides an optimal graphics performance, unprecedented data speed, and seamless transition with its complete backward compatibility to PCIe 1.0/2.0 devices. Intel® I210AT LAN Solution The motherboard comes with two Gigabit LAN controllers and ports which provide a total solution for your networking needs.
Chapter 2: Hardware Information Chapter 2: Hardware Information
2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. 2-2 • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them.
2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an ATX 1.1 compliant chassis. Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.
2.2.
2.2.4 Layout contents Slots/Sockets Page 1. CPU sockets 2-7 2. DDR4 sockets 2-13 3. PCI Express x16 / PCI Express x8 2-17 Onboard LEDs Page 1. Standby Power LED (SBPWR1) 2-19 2. Location LED (LOCLED1) 2-19 3. CATT ERR LED (CATTERR1) 2-20 4. ME LED (MELED1) 2-20 5. Message LED (MLED1) 2-20 6. CPU Warning LED (ERRCPU1) 2-21 7. Q-Code LEDs (QCODE1) 2-21 Jumpers Page 1. Clear RTC RAM (CLRTC1) 2-25 2. VGA controller setting (3-pin VGA_SW1) 2-26 3.
Rear panel connectors Page 1. PS/2 keyboard/mouse port 2-29 2. RJ-45 port for iKVM 2-29 3. Serial port (COM1) 2-29 4. Video Graphics Adapter port 2-29 5. RJ-45 ports for LAN 1-2 2-29 6. Power-on Button 2-29 7. USB 2.0 ports 1 and 2 2-29 8. USB 3.0 ports 1 and 2 2-29 Internal connectors Page 1. erial ATA 6.0 Gbps connector (7-pin SATA 6Gbps 1-6 S connector [Light Blue]) 2-31 2. Hard disk activity LED connector (4-pin HDLED1) 2-31 3. USB 2.
2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA1151 socket designed for the Intel® Xeon® E3-1200 v5 and Intel® Core™ i3 processor. 2.3.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components.
2. Press the load lever with your thumb (A), then move it to the right (B) until it is released from the retention tab. Load lever Do not remove the PnP cap yet from the CPU socket. Doing so may bend the pins of the socket. Retention tab 3. Lift the load lever until the load plate is completely lifted. Load plate 4. Position the CPU above the socket, ensuring that the gold triangle mark is on the bottom-left corner of the socket, then fit the CPU notches to the socket's alignment keys.
5. Close the load plate (A), ensuring that the front edge of the load plate slides under the retention lock (B) then push down the load lever (C). Load lever Retention lock 6. Insert the load lever under the retention tab to remove the PnP cap from the CPU socket. Load lever Retention tab 7. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is evenly spread in a thin layer.
2.3.2 Installing the CPU heatsink The Intel LGA1151 processor requires a specially designed CPU heatsink to ensure optimum thermal condition and performance. ® • When you buy a boxed Intel® processor, a specially designed CPU heatsink or a CPU heatsink with a CPU fan assembly is included depending on the package. If you buy a CPU separately, ensure that you use only Intel® certified multi‑directional CPU heatsink or CPU heatsink with CPU fan.
3. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector. 2.3.3 Uninstalling the CPU heatsink and fan To uninstall the CPU heatsink and fan: 1. Disconnect the CPU fan cable from the connector on the motherboard. 2. Rotate each fastener counterclockwise. 3.
2.3.4 Installing the CPU heatsink in rack The Intel® LGA1151 processor requires a specially designed heatsink to ensure optimum thermal condition and performance. • Ensure that you use qualified heatsink assembly only. • Ensure that you have applied the thermal interface material to the top of the CPU before installing the heatsink and fan. 1. Peel off the sticker on the heatsink metal plate and affix the plate to the back of the motherboard, matching the standoffs to the heatsink screw holes. 2.
2.4 System memory 2.4.1 Overview The motherboard comes with four (4) Double Data Rate 4 (DDR4) Dual Inline Memory Modules (DIMM) sockets. A DDR4 module is notched differently from a DDR, DDR2, or DDR3 module. DO NOT install a DDR, DDR2, or DDR3 memory module to the DDR4 slot. The figure illustrates the location of the DDR4 DIMM sockets: 2.4.2 Memory configurations You may install unbuffered DDR4 DIMMs into the DIMM sockets using the memory configurations in this section.
2.4.3 Installing a DIMM on a single clip DIMM socket 1. Unlock a DIMM socket by pressing the retaining clip outward. 2. Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket. DIMM notch DIMM slot key Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM. 3.
2.5 Expansion slots In the future, you may need to install expansion cards. The following subsections describe the slots and the expansion cards that they support. Ensure to unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1.
2.5.
No.
2.5.8 Installing the Baseboard Management Card Follow the steps below to install an optional ASMB8 Management Card on your motherboard. 1. Locate the Baseboard Management Card header on the motherboard. 2. Orient and press the Management Card in place. The motherboard illustration is for reference only. The motherboard layout and appearance may vary depending on the model, but the installation steps remain the same.
2.6 1. Onboard LEDs Standby Power LED (SBPWR1) The motherboard comes with a standby power LED. The green LED lights up to indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard LED. 2.
3. CATT ERR LED (CATTERR1) The CATT ERR LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate. 4. ME LED (MELED1) The ME LED is an onboard LED that blinks when the the ME is operating properly. 5. Message LED (MLED1) This onboard LED lights up to red when there is temperature warning or a BMC event log is generated.
6. CPU Warning LED (ERRCPU1) The CPU warning LED lights up to indicate that a CPU error or failure has occurred. 7. Q-Code LEDs (QCODE1) The Q-Code LED design provides you with a 2-digit error code that displays the system status. Refer to the Q-Code table on the next page for details.
Q-Code table Code 00 02 03 04 06 10 11 – 14 15 – 18 19 – 1C 2B – 2F 30 31 32 – 36 37 – 3A 3B – 3E 4F 50 – 53 4F 54 55 56 57 58 59 5A 5B 5C – 5F E0 E1 E2 E3 E4 – E7 E8 E9 EA EB EC – EF F0 F1 F2 F3 F4 F5 – F7 F8 Description Not used microcode CACHE_ENABLED PCH initialization CPU_EARLY_INIT PEI Core is started Pre-memory CPU initialization is started Pre-memory System Agent initialization is started Pre-memory PCH initialization is started Memory initialization Reserved for ASL (see ASL Status Codes section b
Code F9 FA FB – FF 60 61 62 63 – 67 68 69 6A 6B – 6F 70 71 72 73 – 77 78 79 7A – 7F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E – 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 Description Recovery capsule is not found Invalid recovery capsule Reserved for future AMI error codes DXE Core is started NVRAM initialization Installation of the PCH Runtime Services CPU DXE initialization is started PCI host bridge initialization System Agent DXE initialization is started System Agent DXE SMM initialization is started System Age
Code A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8– BF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC Description Start of Setup Reserved for ASL (see ASL Status Codes section below) Setup Input Wait Reserved for ASL (see ASL Status Codes section below) Ready To Boot event Legacy Boot event Exit Boot Services event Runtime Set Virtual Address MAP Begin Runtime Set Virtual Address MAP End Legacy Option ROM Initialization System Reset USB hot plug PCI bus hot plug Clean-up of NVRAM Configuration Reset (reset of NV
2.7 1. Jumpers Clear RTC RAM (3-pin CLRTC1) This jumper allows you to clear the CMOS memory system setup parameters by erasing the CMOS Real Time Clock (RTC) RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. Turn OFF the computer and unplug the power cord. 2. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. 3. 2-26 LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allows you to enable or disable the onboard Intel® I210 Gigabit LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature.
4. ME firmware force recovery setting (3-pin ME_RCVR1) This jumper allows you to force Intel Management Engine (ME) boot from recovery mode when ME become corrupted. 5. PCH_MFG1 setting (3-pin PCH_MFG1) This jumper allows you to update the BIOS ME block.
6. Smart Ride Through (SmaRT) setting (3-pin SMART_PSU1) This jumper allows you to enable or disable the Smart Ride Through (SmaRT) function. This feature is disabled by default. Set to pins 1-2 to enable it. When enabled, SmaRT allows uninterrupted operation of the system during an AC loss event.
2.8 Connectors 2.8.1 Rear panel connectors 1. PS/2 keyboard/mouse port (purple/green). This port is for a PS/2 keyboard or mouse. 2. RJ-45 port for iKVM. This RJ-45 port functions only when you enable ASMB8 Management card. 3. Serial port (COM1). This 9-pin communication port is for pointing devices. It is also used for serial interface for data transfer. 4. Video Graphics Adapter port. This port is for a VGA monitor or other VGA-compatible devices. 5. RJ-45 ports for LAN 1-2.
LAN port LED indications Activity/Link LED Status Description Speed LED Status ACT/LINK LED SPEED LED Description OFF No link OFF 10 Mbps connection ORANGE Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection Dedicated Management LAN port (DM_LAN1) LED indications Activity/Link LED Status Description Speed LED Status Description OFF No link OFF 10 Mbps connection ORANGE Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connecti
2.8.2 Internal connectors 1. Serial ATA 6.0 Gbps connectors (7-pin SATA 6Gbps_1-6 connectors [Light Blue]) Supported by the Intel® C232 chipset, these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6Gb/s of data transfer rate. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 10, or RAID 5 configuration. The actual data transfer rate depends on the speed of Serial ATA hard disks installed. 2.
3. USB 2.0 connector (10-1 pin USB78) This connector is for USB 2.0 ports. Connect the USB module cable to this connector. This USB connector complies with USB 2.0 specification that supports up to 480 Mbps connection speed. 4. USB 3.0 connector (20-1 pin USB3_34, A-Type USB3_5) These connectors allow you to connect a USB 3.0 module for additional USB 3.0 front or rear panel ports. With an installed USB 3.0 module, you can enjoy all the benefits of USB 3.
5. CPU, front, and rear fan connectors (4-pin FRNT_FAN1-3, REAR_FAN1, CPU_ FAN1) The fan connectors support cooling fans. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire of each cable matches the ground pin of the connector. 6. • DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components.
7. Trusted Platform Module connector (14-1 pin TPM) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data. A TPM system also helps enhance network security, protects digital identities, and ensures platform integrity. 8. VGA connector (16-1 pin VGA_HDR1) This connector supports the VGA High Dynamic-Range interface.
9. Serial port connector (10-1 pin COM2) This connector is for the serial (COM) port. Connect the serial port module cable to the connector, then install the module to a slot opening at the back of the system chassis. 10. Power Supply SMBus connector (5-pin PSUSMB1) This connector allows you to connect SMBus (System Management Bus) to the PSU (power supply unit) to read PSU information. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface.
11. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1) These connectors are for the ATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. 2-36 • DO NOT forget to connect the 24-pin and the 8-pin power plugs; otherwise, the system will not boot up.
12. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1. System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. 2. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
13. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, and LAN LEDs. 1. Front panel SMB (6-1 pin FPSMB) These connectors connect the front panel SMBus cable. 2. LAN activity LED (2-pin LAN1LINK and 2-pin LAN2LINK) These connectors are for Gigabit LAN activity LEDs on the front panel. 3.
14. Chassis intrusion connector (2-pin INTRUSION) This connector is for a chassis-mounted intrusion detection sensor or switch. Connect one end of the chassis intrusion sensor or switch cable to this connector. The chassis intrusion sensor or switch sends a high-level signal to this connector when a chassis component is removed or replaced. The signal is then generated as a chassis intrusion event. By default, the pin labeled “Chassis Signal” and “Ground” are shorted with a jumper cap.
2-40 Chapter 2: Hardware Information
Chapter 3: Powering Up Chapter 3: Powering Up
3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 2. Be sure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis. 4. Connect the power cord to a power outlet that is equipped with a surge protector. 5. Turn on the devices in the following order: 6. a. Monitor b. External storage devices (starting with the last device on the chain) c.
3.2 Powering off the computer 3.2.1 Using the OS shut down function Using Windows® Server 2008 R2: 1. Click the Start button, move the cursor to the triangle on the right of Log off, then click Shut Down. 2. From the Shutdown Event Tracker, select the option that best describes why you want to shut down the computer. 3. Ensure that the Planned check box is checked. 4. If necessary, key in comments. 5. Click OK. Using Windows® Server 2012: 1. Press ++. 2.
3-4 Chapter 3: Powering Up
Chapter 4: BIOS Setup Chapter 4: BIOS Setup
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. ASUS CrashFree BIOS 3 To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted. 2. ASUS EzFlash Updates the BIOS using a USB flash disk. 3. BUPDATER Updates the BIOS in DOS mode using a bootable USB flash disk drive. Refer to the corresponding sections for details on these utilities.
4.1.2 ASUS EzFlash Utility The ASUS EzFlash Utility feature allows you to update the BIOS using a USB flash disk without having to use a DOS‑based utility. Download the latest BIOS from the ASUS website at www.asus.com before using this utility. The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown. To update the BIOS using EzFlash Utility: 1. Insert the USB flash disk that contains the latest BIOS file to the USB port. 2.
• This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press and select Yes to load the BIOS default settings. 4.1.3 BUPDATER utility The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
The utility verifies the file, then starts updating the BIOS file. ASUS Tek. EzFlash Utility Current Platform Platform : P10S-M Version : 0201 Build date: 07/20/2015 Start Programming Flash. New Platform Platform : P10S-M Version : 0206 Build date: 08/01/2015 DO NOT SHUTDOWN THE SYSTEM!!! Write 75% DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! The utility returns to the DOS prompt after the BIOS update process is completed. 4.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Menu bar Configuration fields General help Navigation keys 4.2.
4.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Advanced, Security, Boot, Monitor, Tool, Save & Exit, Server Mgmt and Event Logs) on the menu bar have their respective menu items. 4.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item and press . 4.2.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date and time. 4.3.1 System Date [Day xx/xx/xxxx] Allows you to set the system date. 4.3.2 System Time [xx:xx:xx] Allows you to set the system time.
4.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. 4.4.1 Trusted Computing Configuration Security Device Support [Enabled] Allows you to enable or disable the BIOS support for security device. Configuration options: [Disabled] [Enabled] 4.4.
System Agent (SA) Configuration Allows you to set System Agent (SA) parameters. VT-d [Enabled] Allows you to enable virtualization technology function on memory control hub. Configuration options: [Disabled] [Enabled] Above 4GB MMIO BIOS assignment [Disabled] Allows you to enable or disable above 4GB MemoryMappedIO BIOS assignment. When aperture size is set to 2048 MB, this is disabled automatically.
DMI Vcm Control [Enabled] Allows you to enable or disable DMI Vcm. Configuration options: [Enabled] [Disabled] DMI Link ASPM Control [L1] This item is for the control of the Active State Power Management on SA side of the DMI link. Configuration options: [Disabled] [L1] PEG Port Configuration PEG 0:1:0 Enable Root Port [Auto] Allows you to enable or disable the root port. Configuration options: [Disabled] [Enabled] [Auto] Max Link speed [Auto] Allows you to configure PEG 0:1:0 Max Speed.
Memory Configuration Maximum Memory Frequency [Auto] Allows you to set the maximum memory frequency. Configuration options: [Auto] [1067] [1333] [1600] [1867] [2133] Max TOLUD [Dynamic] Allows you to set the maximum value of TOLUD. Dynamic assignment would adjust TOLUD automatically based on largest MMIO length of installed graphic controller. Configuration options: [Dynamic] [1 GB] [1.25 GB] [1.5 GB] [1.75 GB] [2 GB] [2.25 GB] [2.5 GB] [2.75 GB] [3 GB] [3.25 GB] [3.
PCI Express Configuration PCI Express Clock Gating [Enabled] Allows you to enable or disable PCI Express Clock Gating for each root port. Configuration options: [Disabled] [Enabled] DMI Link ASPM Control [Enabled] Allows you to enable or disable the control of Active State Power Management on SA side of the DMI link. Configuration options: [Disabled] [Enabled] USB Configuration USB Precondition [Disabled] Allows you to precondition work on USB host controller and root ports for faster enumeration.
Serial IRQ Mode [Continuous] Allows you to configure Serial IRQ mode. Configuration options: [Quiet] [Continuous] High Precision Timer [Enabled] Allows you to enable or disable the High Precision Event Timer.
PCI/PCIE Subsystem Settings PCI Latency Timer [32 PCI Bus Clocks] Allows you to set the value to be programmed into PCI Latency Timer Register. Configuration options: [32 PCI Bus Clocks] [64 PCI Bus Clocks] [96 PCI Bus Clocks] [128 PCI Bus Clocks] [160 PCI Bus Clocks] [192 PCI Bus Clocks] [224 PCI Bus Clocks] [248 PCI Bus Clocks] PERR# Generation [Disabled] Allows you to enable or disable PCI Device tp generation PERR#.
PCIE4 Option ROM [Enabled] Allows you to enable or disable the PCIE4 Option ROM. Configuration options: [Disabled] [Enabled] PCIE5 Option ROM [Enabled] Allows you to enable or disable the PCIE5 Option ROM. Configuration options: [Disabled] [Enabled] PCIE6 Option ROM [Enabled] Allows you to enable or disable the PCIE6 Option ROM. Configuration options: [Disabled] [Enabled] PCIE7 Option ROM [Enabled] Allows you to enable or disable the PCIE7 Option ROM. Configuration options: [Disabled] [Enabled] 4.4.
Legacy USB Support [Enabled] [Disabled] [Enabled] [Auto] The USB devices can be used only for the BIOS setup program. It cannot be recognized in boot devices list. Enables the support for USB devices on legacy operating systems (OS). Allows the system to detect the presence of USB devices at startup. If detected, the USB controller legacy mode is enabled. If no USB device is detected, the legacy USB support is disabled.
NVMe Configuration You may view the NVMe controller and Drive information if an NVMe device is connected. Onboard LAN Configuration Intel LAN1 Enable [Enabled] Allows you to enable or disable the Intel LAN. Configuration options: [Disabled] [Enabled] Intel LAN ROM Type [PXE] Allows you to select the Intel LAN ROM type. Configuration options: [Disabled] [PXE] [iSCSI] Intel LAN2 Enable [Enabled] Allows you to enable or disable the Intel LAN.
Serial Port 1 Configuration Allows you to set the parameters of Serial Port 1. Serial Port [Enabled] Allows you to enable or disable Serial Port. Configuration options: [Disabled] [Enabled] Change Settings [Auto] Allows you to choose the setting for Super IO device.
Serial Port Console Redirection COM1 / COM2 Console Redirection [Disabled] Allows you to enable or disable the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings This item becomes configurable only when you enable the Console Redirection item. The settings specify how the host computer and the remote computer (which the user is using) will exchange data.
Bits per second [57600] Selects serial port transmission speed. The speed must be matched on the other side. Long or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400] [57600] [115200] Data Bits [8] Configuration options: [7] [8] Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [None] None. [Even] parity bit is 0 if the num of 1’s in the data bits is even.
Legacy Console Redirection Settings Legacy Serial Redirection Port [COM1] Allows you to select a COM port to display redirection of Legacy OS and Legacy OPROM Messages. Configuration options: [COM1] [COM2] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Allows you to enable or disable the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled].
ACPI Settings Enable Hibernation [Enabled] Allows you to enable or disable the ability of the system to hibernate (OS/S4 Sleep State). Configuration options: [Disabled] [Enabled] This option may be not be effective with some OS. ACPI Sleep State [S3 (Suspend to RAM)] Allows you to select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed.
Power On By Ring [Disabled] [Disabled] [Enabled] Disables the Ring devices to generate a wake event. Enables the Ring devices to generate a wake event. This item functions only if there is a serial port (COM1) connector on the motherboard. Power On By RTC [Disabled] [Disabled] [Enabled] Disables RTC to generate a wake event. When set to [Enabled], the items RTC Alarm Date (Days) and Hour/Minute/ Second will become user-configurable with set values.
4.4.4 CPU Configuration The items in this menu show the CPU-related information that the BIOS automatically detects. Some items may not appear if your CPU does not support the related functions. Navigate to the second page of the screen to see the rest of items in this menu by pressing the Up or Down arrow keys. To quickly go to the last item of the second page, press the Page Down button. Press the Page Up button to go back to the first item in the first page.
Adjacent Cache Line Prefetch [Enabled] This item allows you to enable or disable prefetching of adjacent cache lines. Configuration options: [Disabled] [Enabled] CPU AES [Enabled] Allows you to enable or disable the CPU Advance Encryption Standard instructions. Configuration options: [Disabled] [Enabled] Boot performance mode [Max Non-Turbo Performance] Allows you to select the CPU performance state during system boot before the operating system takes control.
C-State Un-demotion [C1 and C3] Allows you to enable or disable the un-demotion of the C-State. Configuration options: [Disabled] [C1] [C3] [C1 and C3] Package C state demotion [Enabled] Allows you to enable or disable the Package C state demotion. Configuration options: [Disabled] [Enabled] Package C state undemotion [Enabled] Allows you to enable or disable the Package C state undemotion.
4.4.5 SATA Configuration SATA Controller(s) [Enabled] Allows you to enable or disable the SATA Device. Configuration options: [Enabled] [Disabled] The following items appear only when you set SATA Controller(s) to [Enabled]. SATA Mode Selection [AHCI] This item allows you to set the SATA configuration. [AHCI] Set to [AHCI] when you want the SATA hard disk drives to use the AHCI (Advanced Host Controller Interface).
Software Feature Mask Configuration RAID0 [Enabled] Allows you to enable or disable the RAID0 feature. Configuration options: [Disabled] [Enabled] RAID1 [Enabled] Allows you to enable or disable the RAID1 feature. Configuration options: [Disabled] [Enabled] RAID10 [Enabled] Allows you to enable or disable the RAID10 feature. Configuration options: [Disabled] [Enabled] RAID5 [Enabled] Allows you to enable or disable the RAID5 feature.
Smart Response Technology [Enabled] Allows you to enable or disable the Smart Response Technology. Configuration options: [Disabled] [Enabled] OROM UI Normal Delay [4 sec] Allows you to select the delay time of the OROM UI Splash Screen in a normal status. Configuration options: [2 sec] [4 sec] [6 sec] [8 sec] RST Force Form [Disabled] Allows you to enable or disable Form for Intel Rapid Storage Technology.
4.4.6 Network Stack Configuration Network Stack [Disabled] Allows you to enable or disable UEFI Network Stack. Configuration options: [Disabled] [Enabled] The following items appear only when you set the Network Stack to [Enabled]. Ipv4 PXE Support [Enabled] Enables or disables the Ipv4 PXE Boot Support. If disabled, Ipv4 PXE boot option will not be created. Configuration options: [Disable] [Enable] Ipv6 PXE Support [Enabled] Enables or disables the Ipv6 PXE Boot Support.
4.4.7 CSM Configuration CSM Support [Enabled] This option allows you to enable or disable CSM Support. Configuration options: [Disabled] [Enabled] The following items appear only when you set the CSM Support to [Enabled]. GateA20 Active [Upon Request] This allows you to set the GA20 option. [Upon Request] GA20 can be disabled using BIOS services. [Always] Do not allow disabling GA20; this option is useful when any RT code is executed above 1MB.
Network / Storage / Video [Legacy] This option allows you to control the execution of UEFI and Legacy PXE/ Storage/ Video OpROM. Configuration options: [UEFI ] [Legacy] Other PCI devices [Legacy] This item determines the OpROM execution policy for devices other than Network, Storage, or Video. Configuration options: [UEFI ] [Legacy] NVMe controller and Drive information You may view the NVMe controller and Drive information if an NVMe device is connected. 4.4.
4.5 Security Menu This menu allows a new password to be created or a current password to be changed. The menu also enables or disables the Secure Boot state and lets the user configure the System Mode state. Administrator Password To set an administrator password: 1. Select the Administrator Password item and press . 2. From the Create New Password box, key in a password, then press . 3. Confirm the password when prompted. To change an administrator password: 1.
User Password To set a user password: 1. Select the User Password item and press . 2. From the Create New Password box, key in a password, then press . 3. Confirm the password when prompted. To change a user password: 1. Select the User Password item and press . 2. From the Enter Current Password box, key in the current password, then press . 3. From the Create New Password box, key in a new password, then press . 4. Confirm the password when prompted.
Key Management This item only appears when you set the Secure Boot Mode to [Custom]. This allows you to modify Secure Boot variables and set Key Management page. Provision Factory Default Keys [Disabled] Configuration options: [Disabled] [Enabled] Enroll All Factory Default Keys / Delete all Secure Boot variables This item will ask you if you want to Install Factory Default secure variables. Select Yes if you want to load the default secure variables, otherwise select No.
4.6 Boot Menu The Boot menu items allow you to change the system boot options. Bootup NumLock State [On] Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On] Boot Logo Display [Disabled] Allows you to enable or disable the full screen logo display feature. [Auto] Auto adjustment for Windows requirements. [Full Screen] Maximize the boot logo size. [Disabled] Hide the logo during POST.
Set the booting order of network devices. Boot Option #1 [IBA GE Slot 0300 v1572] Configuration options: [IBA GE Slot 0300 v1572] [Disabled] Network Device BBS Priorities This item allows you to set the booting from network. Hard Drive BBS Priorities These items appear only when you connect SATA ODD or hard drive to the SATA ports and allow you to set the booting order of the SATA devices. 4.
4.8 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. Start EzFlash Allows you to run ASUS EZ Flash BIOS ROM Utility when you press . Refer to the ASUS EzFlash Utility section for details. 4.9 Save & Exit menu The Exit menu items allow you to save or discard your changes to the BIOS items. Pressing does not immediately exit this menu.
Launch EFI Shell from filesystem device Attempts to launch EFI Shell application (Shell.efi) from one of the available filesystem devices. 4.10 Server Mgmt menu The Server Management menu displays the server management status and allows you to change the settings. OS Watchdog Timer [Disabled] This item allows you to start a BIOS timer which can only be shut off by Management Software after the OS loads.
System Event Log Allows you to change the System Event Log configuration. All values changed here do not take effect until computer is restarted. Erase SEL [No] Allows you to choose options for erasing SEL. Configuration options: [No] [Yes, On next reset] [Yes, On every reset] When SEL is Full [Do Nothing] Allows you to choose options for reactions to a full SEL.
BMC network configuration The sub-items in this configuration allow you to configure the BMC network parameters. DM_LAN1 / Shared LAN Config Address source [Previous State] This item allows you to configure LAN channel parameters statistically or dynamically (by BIOS or BMC). Previous State option will not modify any BMC network parameters during BIOS phase. Configuration options: [Previous State] [Static] [DynamicBmcDhcp] View System Event Log This item allows you to view the System Event Log Records.
IPv6 BMC Network Configuration This item allows you to configure the parameter settings of IPv6 BMC network. IPv6 Display Full Field [Enable] Displays the Full or Brief IPv6 Field. Configuration options: [Disable] [Enable] IPv6 Display Full Formula [Enable] Displays the Full or Brief IPv6 Formula. Configuration options: [Disable] [Enable] IPv6 Display Letter Case [Upper Case] Displays the uppercase or lowercase letters of the alphabet.
4.11 Event Logs menu The Event Logs menu items allow you to change the event log settings and view the system event logs. 4.11.1 Change Smbios Event Log Settings Press to change the Smbios Event Log configuration. Enabling/Disabling Options Smbios Event Log [Enabled] Change this to enable or disable all features of Smbios Event Logging during boot. Configuration options: [Disabled] [Enabled] • The following items appears only when you set Smbios Event Log to [Enabled].
When Log is Full [Do Nothing] Allows you to choose options for reactions to a full Smbios Event Log. Configuration options: [Do Nothing] [Erase Immediately] Smbios Event Log Standard Settings Log System Boot Event [Disabled] Allows you to enable or disable logging of System boot event.
Chapter 5: RAID Configuration
5.1 Setting up RAID The motherboard comes with the Intel® C232 controller that supports Intel® Rapid Storage Technology enterprise Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for both Windows® OS and Linux). 5.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks.
5.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. Install the SATA hard disks into the drive bays following the instructions in the system user guide. 2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. 3.
5.2 Intel® Rapid Storage Technology enterprise SATA Option ROM Utility The Intel® Rapid Storage Technology enterprise SATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. Before you proceed, ensure that you have installed the Serial ATA hard disk drives, and have set the correct SATA mode in the BIOS setup. You can refer to sections 5.1.
5.2.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select 1. Create RAID Volume and press . 2. Key in a name for the RAID set and press . Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 4.5.0.1012 Copyright(C) 2003-15 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Strips) Disks: Select Disks Strip Size: 128KB Capacity: 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only) then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7.
5.2.2 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . 2. From the Delete Volume Menu, press the up/down arrow keys to select the RAID set you want to delete then press . Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 4.5.0.1012 Copyright(C) 2003-15 Intel Corporation. All Rights Reserved.
5.2.3 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . 2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want to reset, then press . A small triangle before the Port number marks the selected drive.
5.2.4 Exiting the Intel® Rapid Storage Technology enterprise SATA Option ROM utility To exit the utility: 1. From the utility main menu, select 4. Exit then press . 2. Press to exit or press to return to the utility main menu. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 5.2.5 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. When done, the status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 4.5.0.1012 Copyright(C) 2003-15 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume RAID Volumes: ID Name 1 Volume0 [ MAIN MENU ] 3. Reset Disks to Non-RAID 4. Mark Disks as Spare 5.
5.2.6 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multiRAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utility. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. Reboot the system and press to enter the BIOS setup utility during POST. 2. Go to the Boot menu and select the boot option priority. 3.
5.3 Intel® Rapid Storage Technology enterprise (Windows) The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. Please refer to the installation instructions in Chapter 6.
5.3.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select Create Volume then select volume type and click Next. 2. Key in a name for the RAID set, then select the array disks. 3. Select the Volume Size tab then drag the bar to set the volume size. 4. Click Next. • If you do not want to keep the data on one of the selected disks, select NO when prompted. • If you want to Enable volume write-back cache or Initialize volume, click Advanced.
5. Confirm the volume creation, then click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can continue using other applications during this time. 6. Wait until the process is completed, then click OK when prompted. You still need to partition your new volume using Windows Disk Management before adding any data. The created RAID set is displayed in the Volumes list. If you wish to change the settings, go to Volume Properties.
5.3.2 Changing a Volume Type To change the volume type in Volume Properties: 1. Click the SATA array items you want to change in Volumes field. 2. From the Volume Properties field, select Type: RAID 1 Change type. 3. You can also change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only) and click OK. The available stripe size values range from 4 KB to 128 KB.
5.3.3 Deleting a volume Be cautious when deleting a volume. You will lose all data on the hard disk drives. Before you proceed, ensure that you back up all your important data from your hard drives. To delete a volume: 5-16 1. From the Volumes field in the utility main menu, select the volume that you want to delete. 2. From the Volume Properties field, select Delete volume. 3. Click Yes to delete the volume and return to the utility main menu, or click No to return to the main menu.
5.3.4 Preferences System Preferences Allow you to set to show the notification area icon and show system information, warning, or errors here.
5-18 Chapter 5: RAID Configuration
Chapter 6: Driver Installation Chapter 6: Driver Installation
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a USB flash drive with RAID driver When installing Windows® Server OS, you can load the RAID driver from a USB flash drive.
3. Click Load Driver. 4. A message appears reminding you to insert the installation media containing the driver of the RAID controller driver (the installation media can be a CD, DVD, or USB flash drive). • If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive. • Or you may connect a USB flash drive containing the RAID controller driver. Click Browse to continue. 5.
7. When the system finishes loading the RAID driver, • Replace the motherboard Support DVD with the Windows Server installation disc. • Remove the USB flash drive. Select the drive to install Windows and click Next. 8. 6-4 Follow succeeding screen instructions to continue.
6.2 Management applications and utilities installation The support DVD that is bundled with your motherboard contains drivers, management applications, and utilities that you can install to maximize the features of your motherboard. • The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for the latest updates on software and utilities. • The support DVD is supported on Windows® Server 2008 R2 and Windows® Server 2012. 6.
6.3.1 Drivers menu tab The Drivers Menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices. 6.3.2 Utilities menu tab The Utilities menu displays the software applications and utilities that the motherboard supports.
6.3.3 Manual menu The Manual menu provides the link to the P10S-M user guide. You need an internet browser installed in your OS to view the User Guide. 6.3.4 Contact information menu The Contact menu displays the ASUS contact information, e-mail addresses, and useful links if you need more information or technical support for your motherboard.
6.4 Installing the Intel® Chipset device Software driver This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows® Operating System. To install the Intel® chipset device software: 1. Restart the computer. 2. Log in with Administrator privileges. 3. Insert the Motherboard Support DVD to the optical drive.
6. Select Yes to accept the terms of the License Agreement and continue the process. 7. Read the Readme File Information and press Next to continue the installation. 8. Toggle Yes, I want to restart the computer now and click Finish to complete the setup process.
6.5 Installing the Intel® I210 Gigabit Adapters driver This section provides the instructions on how to install the Intel® I210 Gigabit Adapter Driver on the system. To install the Intel® I210 Gigabit Adapters Driver on the Windows® operating system: 1. Restart the computer. 2. Log on with Administrator privileges. 3. Insert the motherboard/system support DVD to the optical drive. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.
6. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 7. Tick I accept the terms in the license agreement and click Next to continue. 8. From the Setup Options window, click Next to start the installation. By default, Intel(R) PROSet for Windows Device Manager and Windows PowerShell Module are ticked.
6-12 9. Click Install to start the installation. 10. When the installation is done, press Finish to complete the installation.
6.6 Installing the VGA driver This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. To install the ASPEED VGA driver: 1. Restart the computer. 2. Log in with Administrator privileges. 3. Insert the Motherboard Support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.
6-14 6. Click Install to proceed with the installation. 7. Click Finish to complete the installation.
Appendix
P10S-M block diagram A-2 Appendix
Simplified EU Declaration of Conformity English ASUSTeK Computer Inc. hereby declares that this device is in compliance with the essential requirements and other relevant provisions of related Directives. Full text of EU declaration of conformity is available at: www.asus.com/support Français AsusTek Computer Inc. déclare par la présente que cet appareil est conforme aux critères essentiels et autres clauses pertinentes des directives concernées.
ASUS contact information ASUSTeK COMPUTER INC. Address 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan Telephone +886-2-2894-3447 Fax +886-2-2890-7798 Web site https://www.asus.com Technical Support Telephone +86-21-38429911 Fax +86-21-58668722 ext: 9101 Online Support https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=en ASUSTeK COMPUTER INC. (Taiwan) Address 4F, No. 150, Li-Te Rd.
ASUS contact information ASUS COMPUTER INTERNATIONAL (America) Address Fax Web site 48720 Kato Rd., Fremont, CA 94538, USA +1-510-608-4555 https://www.asus.com/us/ Technical Support Support fax General support Online support +1-812-284-0883 +1-812-282-2787 https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=en-us ASUS COMPUTER GmbH (Germany and Austria) Address Fax Web site Harkort Str. 21-23, 40880 Ratingen, Germany +49-2102-959911 https://www.asus.
ASUS contact information ASUS Holland BV (The Netherlands) Address Web site Marconistraat 2, 7825GD EMMEN, The Netherlands https://www.asus.com/nl/ Technical Support Telephone Fax E-mail Online Support +31-(0)591-5-70292 +31-(0)591-666853 advance.rma.eu@asus.com h ttps://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=nl-nl ASUS Polska Sp. z o.o. (Poland) Address Web site Ul. Postępu 6, 02-676 Warszawa, Poland https://www.asus.
FCC COMPLIANCE INFORMATION Per FCC Part 2 Section 2.1077 Responsible Party: Address: Phone/Fax No: Asus Computer International 48720 Kato Rd, Fremont, CA 94538 (510)739-3777/(510)608-4555 hereby declares that the product Product Name : Model Number : Motherboard P10S-M compliance statement: This device complies with part 15 of the FCC Rules.
A-8 Appendix