User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Basic Installation
- Chapter 3: BIOS Setup
- Chapter 4: Software Support
- Chapter 5: RAID Support
- 5.1 RAID configurations
- 5.1.1 RAID definitions
- 5.1.2 Installing Serial ATA hard disks
- 5.1.3 Setting the RAID item in BIOS
- 5.1.4 Intel® Rapid Storage Technology enterprise SATA Option ROM Utility
- 5.1.5 Creating a RAID set
- 5.1.6 Deleting a RAID set
- 5.1.7 Resetting disks to Non-RAID
- 5.1.8 Exiting the Intel® Rapid Storage Technology enterprise SATA Option ROM utility
- 5.1.9 Rebuilding the RAID
- 5.1.10 Setting the Boot array in the BIOS Setup Utility
- 5.2 Intel® Rapid Storage Technology enterprise (Windows)
- 5.1 RAID configurations
- Chapter 6: Multi GPU Support
- Appendix
ASUS P10S WS
3-41
Chapter 3
The following four items appear only when you set Chassis Fan 1-4 Prole to [Manual].
Chassis Fan 1-4 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Chassis Fan 1-4
temperature. The values range from 20 to 75.
Chassis Fan 1-4 Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Chassis Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Chassis Fan 1-4 will operate at the maximum
duty cycle.
Chassis Fan 1-4 Middle Temperature [45]
Use the <+> or <-> keys to adjust the middle limit of the Chassis Fan 1-4
temperature. The values range from 20 to 75.
Chassis Fan 1-4 Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the maximum Chassis Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the middle limit, the Chassis Fan 1-4 will operate at the middle
duty cycle.
Chassis Fan 1-4 Lower Temperature [40]
Use the <+> or <-> keys to adjust the lower limit of the Chassis Fan 1-4
temperature. The values range from 20 to 75. The Chassis Fan 1-4 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Chassis Fan 1-4 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum Chassis Fan 1-4 fan duty
cycle. The values range from 0% to 100%. When the CPU temperature is
under the limit, the Chassis Fan 1-4 fan will operate at the minimum duty
cycle.
Anti Surge Support [On]
Enable this item for Over Voltage Protection (OVP) and Under Voltage Protection (UVP)
functions.
Conguration options: [On] [Off]
Chassis Intrude Detect Support [Off]
Enable this item for Chassis Intrude Detect Support function.
Conguration options: [On] [Off]