Motherboard P11C-M/4L
T16273 4.00 版 2020 年 2 月發行 版權說明 © ASUSTeK Computer Inc. All rights reserved.
Offer to Provide Source Code of Certain Software This product may contain copyrighted software that is licensed under the General Public License (“GPL”) and under the Lesser General Public License Version (“LGPL”). The GPL and LGPL licensed code in this product is distributed without any warranty. Copies of these licenses are included in this product.
目錄內容 安全性須知..................................................................................................................................... viii 電氣方面的安全性........................................................................................................... viii 操作方面的安全性........................................................................................................... viii 產品回收與處理..................................................................................................................
目錄內容 2.5.5 PCI Express x16 插槽 (x16 Gen3 link).......................................................2-17 2.5.7 安裝基板管理卡...................................................................................................2-18 2.6 內建指示燈............................................................................................................................2-19 2.7 跳線選擇區............................................................................................................................2-22 2.
目錄內容 4.4.11 PCI/PCIE Subsystem Settings(PCI/PCIE 子系統設定)..................4-20 4.4.12 USB Configuration(USB 設定)...............................................................4-20 4.4.13 網路堆疊設定.....................................................................................................4-22 4.4.13 CSM 設定(CSM Configuration).............................................................4-23 4.4.14 NVMe Configuration(NVMe 設定)........................................................4-24 4.4.
目錄內容 5.3 Intel® Rapid Storage Technology enterprise 工具程式 (Windows)..................5-12 5.3.1 建立 RAID 陣列...................................................................................................5-13 5.3.2 變更陣列類型.......................................................................................................5-15 5.3.3 移除陣列.................................................................................................................5-16 5.3.4 偏好設定............................................
安全性須知 電氣方面的安全性 • 為避免可能的電擊造成嚴重損害,在搬動電腦主機之前,請先將電腦電源線暫時 從電源插槽中拔掉。 • 當您要加入硬體裝置到系統中或者要移除系統中的硬體裝置時,請務必先連接該 裝置的訊號線,然後再連接電源線。可能的話,在安裝硬體裝置之前先拔掉電腦 的電源供應器電源線。 • 當您要從主機板連接或拔除任何的訊號線之前,請確定所有的電源線已事先拔 掉。 • 在使用擴充卡之前,我們建議您可以先尋求專業人士的協助。這些裝置有可能會 干擾接地的迴路。 • 請確定電源供應器的電壓設定已調整到本國/本區域所使用的電壓標準值。若您不 確定您所屬區域的供應電壓值為何,那麼請就近詢問當地的電力公司人員。 • 如果電源供應器已損壞,請不要嘗試自行修復。請將之交給專業技術服務人員或 經銷商來處理。 操作方面的安全性 • 在您安裝主機板以及加入硬體裝置之前,請務必詳加閱讀本手冊所提供的相關資 訊。 • 在使用產品之前,請確定所有的排線、電源線都已正確地連接好。若您發現有任 何重大的瑕疵,請儘速聯絡您的經銷商。 • 為避免發生電氣短路情形,請務必將所有沒用到的螺絲、迴紋針及其他零件收 好,不要遺留在主機板上或電
產品回收與處理 華碩與資源回收業者以最高標準相互配合,以保護我們的環境,確保工作者的安 全,以及遵從全球有關環境保護的法律規定。我們保證以資源回收的方式回收以往生 產的舊設備,透過多樣的方式保護環境。 如欲了解更多關於華碩產品資源回收資訊與聯絡方式,請連線上網至 C S R (Corporate Social Responsibility)網頁:http://csr.asus.com/english/Takeback.
關於這本使用手冊 產品使用手冊包含了所有當您在安裝華碩 P11C-C/4L 主機板時所需用到的資訊。 使用手冊的編排方式 使用手冊是由下面幾個章節所組成: • 第一章:產品介紹 本章節描述本主機板的功能和新技術。 • 第二章:硬體裝置資訊 本章節描述所有您在安裝系統元件時必須完成的硬體安裝程式。詳細內容有: 處理器與記憶體安裝、跳線選擇區設定以及主機板的各種裝置連接埠。 • 第三章:開啟電源 本章節說明開啟電腦電源的順序以及電腦開機後所發出各種不同類型嗶嗶聲的 代表意義。 • 第四章:BIOS 程式設定 本章節描述如何使用 BIOS 設定程式中的每一個選單項目來變更系統的設定。 此外也會詳加介紹 BIOS 各項設定值的使用時機與參數設定。 • 第五章: RAID 磁碟陣列設定 本章節提供本主機板的 RAID 設定資訊。 • 第六章:安裝驅動程式 本章節介紹本主機板驅動程式的安裝。 • 附錄 在本附錄裡將列出相關的聯絡資訊與認證資訊。 x
提示符號 為了能夠確保您正確地完成主機板設定,請務必注意下面這些會在本手冊中出現的 標示符號所代表的特殊含意。 警告:提醒您在進行某一項工作時要注意您本身的安全。 小心:提醒您在進行某一項工作時要注意勿傷害到電腦主機板元件。 重要: 此符號表示您必須要遵照手冊所描述之方式完成一項或多項軟硬體 的安裝或設定。 注意:提供有助於完成某項工作的訣竅和其他額外的資訊。 跳線帽及圖示說明 主機板上有一些小小的塑膠套,裡面有金屬導線,可以套住選擇區的任二隻針腳 (Pin)使其相連而成一通路(短路),本手冊稱之為跳線帽。 有關主機板的跳線帽使用設定,茲利用以下圖示說 明。以下圖為例,欲設定為「Jumper™ Mode」,需在 選擇區的第一及第二隻針腳部份蓋上跳線帽,本手冊 圖示即以塗上底色代表蓋上跳線帽的順位元,而空白 的部份則代表空接針。以文字表示為:[1-2]。 1 2 Jumper Mode 2 3 Jumper Free (Default) 因此,欲設定為「JumperFree™ Mode」,以右圖表 示即為在「第二及第三隻針腳部份蓋上跳線帽」,以文 字表示即為:[2-3]。 哪裡可以找到更多的產
P11C-M/4L 規格概要 處理器/系統匯流排 1 x Socket LGA1151 I n t e l ® X e o n ® E-21x x / E-22x x 處理器家族 (95W) Intel® 第八代 / 第九代 Core™ i3 處理器 Intel® Pentium™ 處理器 Intel® Celeron™ 處理器 核心邏輯 Intel® C242 晶片組 Micro ATX 規格,9.6 x 9.6 英吋 尺寸 風扇速度控制 華碩獨家功能 Rack Ready(Rack 與 Pedestal 雙用途) ASWM Enterprise 記憶體 插槽總數 4(2 通道) 電壓準位 1.2V 最大容量 最高支援 128GB 記憶體類型 DDR4 2666/2400 ECC/non-ECC UDIMM 32GB、16GB、8GB、4GB 記憶體容量 * PCI/PCI-E 插槽總數 2 插槽 1 - 插槽 2 - 擴充插槽 插槽 3 (依照 S S I 順位 插槽 4 元號排列) 插槽 5 - 請參考華碩官方網站 tw.asus.
P11C-M/4L 規格概要 SATA 控制器 存儲 SAS 控制器 TPM 連接埠 PSU 連接埠 管理連接埠 USB 連接埠 內建 I/O 連接埠 風扇連接埠 5 x 4 pin 連接埠 SMBus 1 機殼開啟警告排針 前面板網路指示燈 序列埠插槽 VGA 插槽 M.2 插槽 外接序列埠 1 4 1 1 2 1 2 x USB 3.1 Gen 2 連接埠 2 x USB 3.1 Gen 1 連接埠 1 後側面板 I/O 連接 外接 USB 連接埠 埠 VGA 連接埠 管理方案 監控 環境要求 Intel® C242: - 6 * S A T A 6G b/s 連接埠(4 個從 m i n i S A S H D 連接埠),支援 2 個 M.2(N G F F 2210/2280/2260/2242,PCI-E Gen3x2 link 或 S A T A 模式。當 M.
xiv
第一章: 產品介紹 您可以在本章節中發現諸多華碩所賦予本 主機板的優異特色,以及所有能夠套用在本 主機板的新產品技術。 1
1.1 歡迎加入華碩愛好者的行列! 再度感謝您購買此款華碩 P11C-M/4L 主機板! 本主機板的問世除了再度展現華碩對於主機板一貫具備的高品質、高效能以及高穩 定度的嚴格要求,同時也添加了許多新的功能以及大量套用在它身上的最新技術,使 得 P11C-M/4L主機板成為華碩優質主機板產品線中不可多得的閃亮之星。 在您拿到本主機板包裝盒之後,請馬上檢查下面所列出的各項標準配件是否齊全。 1.
1.3 序列號標籤 在請求華碩技術支援團隊的技術支援之前,請務必留意一下主機板的序列號,此序 列號由 12 位元字母組成(xxS2xxxxxxx),如下圖所示。只有當您了解產品的正確 序列號,華碩技術支援團隊成員才能針對您提出的問題提供更快速而讓您滿意的解決 方案。 P11C-M/4L xxS2xxxxxxxx Made in China 合格 1.4 特殊功能 1.4.1 產品特性 最新處理技術 本主機板具備 LGA1151 處理器插座,可支援最新的 Intel® Xeon® E-22xx / Core™ i3 / Pentium™ / Celeron™ 系列處理器,內建記憶體和 PCI Express 控制器,可支援 2 頻道(每顆 CPU 支援 4 根記憶體)DDR4 記憶體和 16 個 PCI Express 3.
Inte® I210AT 網路解決方案 本主機板擁有兩個千兆網路控制器與網路埠,可提供符合您網路使用需求的完整解 決方案。內建 Intel® I210AT 千兆網路控制器使用 PCI Express 連接埠,可達到接近 千兆頻寬的網路連接。 支援增強型 Intel SpeedStep 技術 (EIST) 增強型 Intel SpeedStep 技術 (EIST) 可智慧管理 CPU 資源,如依據系統覆載和速度 或電源要求自動調整 CPU 電壓準位和核心頻率。 支援 Serial ATA III 技術 本主機板透過 Serial ATA 連接埠與 Intel® C242 晶片組支援 Serial ATA III 6Gb/s 技術。該技術增強穩定性、提供更快的速度和兩倍於目前系統的頻寬。 支援 USB 2.0 規格 本主機板支援通用序列式匯流排 U S B 2.0 規格,傳輸速率從 U S B 1.1 規格的 12Mbps 一舉提升到 USB 2.0 規格的 480Mbps。USB 2.0 規格同時也可向下相容於 USB 1.1 規格。 支援 USB 3.
第二章: 硬體裝置資訊 本章節描述了所有您在安裝系統元件 時所必須完成的硬體安裝程式。詳細內容 有:處理器與記憶體、跳線選擇區設定以 及主機板的各種裝置連接埠。 2
2.
2.2 主機板概觀 在您開始安裝之前,請確定您所購買的電腦主機機殼是否可以容納本主機板,並且 機殼內的主機板固定孔位元是否能與本主機板的螺絲孔位吻合。 為了優化主機板功能,建議您將主機板安裝在一個相容 ATX 1.1 的機殼內。 為方便在電腦主機機殼安裝或取出主機板,請務必先將電源供應器移 開!當您安裝或移除主機板的時候,必須確保電源供應器的插頭已經被 移除,否則可能導致主機板上的元件損壞。 2.2.1 主機板的擺放方向 當您安裝主機板到電腦主機機殼內時,務必確認置入的方向是否正確。帶有外部連 接埠的方向應是朝向主機機殼的後方面板,而且您也會發現主機機殼後方面板會有相 對應的預留孔位元。請參考下圖所示。 2.2.
2.2.
2.2.4 主機板元件說明 插槽 頁數 1. CPU sockets 2-7 2. DDR4 sockets 2-13 3. PCI Express x16 / PCI Express x8 2-17 指示燈 頁數 1. Standby Power LED (SBPWR1) 2-19 2. CATT ERR LED (CATTERR1) 2-19 3. ME LED (MELED1) 2-20 4. BMC LED (BMCLED1) 2-20 5. Message LED (MLED1) 2-21 跳線 頁數 1. Clear RTC RAM (CLRTC1) 2-22 2. VGA controller setting (3-pin VGA_SW1) 2-23 3. LAN controller setting (3-pin LAN_SW1-4) 2-23 4. ME firmware force recovery setting (3-pin ME_RCVR1) 2-24 5.
2-6 內部連接埠 頁數 1. Serial ATA 6.0 Gbp/s connectors (7-pin SATA 6Gbps_1-6) 2-29 2. Hard disk activity LED connector (4-pin HDLED1) 2-29 3. USB 2.0 connectors (10-1 pin USB1112; 4-pin Type-A USB7) 2-30 4. USB 3.1 Gen 1 connector (20-1 pin USB3_34) 2-30 5. Fan connectors (4-pin CPU_FAN1, FRNT_FAN1-3, REAR_FAN1) 2-31 6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) 2-31 7. Trusted Platform Module connector (14-1 pin TPM) 2-32 8. VGA connector (16-pin VGA_HDR1)) 2-32 9.
2.3 中央處理器(CPU) 本主機板具備一個 L G A1151 處理器插槽,本插槽是專為 L G A 封裝的 I n t e l ® Xeon® E-21xx / E-22xx 處理器家族、Intel® 第八代 / 第九代 Core™ i3 處理器、Intel® Pentium™ 以及 Intel® Celeron™系列處理器所設計。 確認您安裝的是專為 LGA 1151 所設計的正確處理器。請勿將其他插槽專 用的處理器安裝於 LGA1151 插槽。 • 安裝處理器之前請先確認所有電源線皆已經拔除。 • 在您購買本主機板之後,請確認在處理器插座上附有一個 PnP 保護 蓋,並且插座接點沒有彎曲變形。若是保護蓋已經毀壞或是沒有保護 蓋,或者是插座接點已經彎曲,請立即與您的經銷商連絡。 • 本保固不包括處理器插座因遺失、錯誤的安裝或不正確的移除 P n P 保護蓋所造成的毀壞。 2.3.1 安裝中央處理器 請依照以下步驟安裝處理器: 1.
2. 以手指壓下固定扳手並將其稍向 左側推(A),這麼做可使扳手脫 離固定扣並鬆開 C P U 輔助安裝盒 (B)。 固定扳手 CPU 安裝盒上的 PnP 保護蓋是 用以保護插槽上的接腳之用, 因此只有在 C P U 安裝妥當之 後,才可將其移除。 3. 固定扣 將插座側邊的固定扳手按照箭頭方向拉 起至上蓋完全打開。 安裝盒上蓋 4.
5. 將上蓋(A)重新蓋上,確保固定扳手 的前端可安插入固定扣(B)下方,并 扣于固定扣下(C)。 固定扳手 固定扣 6. 將固定扳手安插于固定扣下,然後從 CPU 插槽中將 PnP 保護蓋向外推並取下。 固定扳手 固定扣 7.
2.3.2 安裝散熱器和風扇 Intel® LGA1151 處理器需要搭配安裝經過特殊設計的散熱器與風扇,方能得到最佳 的散熱效能。 • 若您所購買的是盒裝 Intel 處理器,則產品包裝中即已內含有一組專 用的散熱器與風扇;若您所購買的是散裝的處理器,請確認您所使用 的 CPU 散熱器已透過 Intel 的相關認證。 • 請務必使用相容 LGA1151 處理器的散熱器與風扇。LGA1151 處理器 插槽不相容 LGA775 與 LGA1366 處理器插槽的大小尺寸。 若您所購買的是散裝的 CPU 散熱器與風扇,請在安裝之前確認風扇散熱 器上的金屬銅片或者是 CPU 上面有確實塗上散熱膏。 在安裝處理器的風扇和散熱器之前,請先確認主機板已經安裝至機殼 上。 請依照下面步驟安裝處理器的散熱器和 風扇: 1. 將散熱器放置在已安裝好的 C P U 上 方,並確認主機板上的四個孔位元與 散熱器的四個扣具順位元相吻合。 2.
3. 當風扇、散熱片以及支撐機構都已安裝完畢,接著請將風扇的電源線插到主機板 上標示有“CPU_FAN1”的電源插槽。 若您未連接 CPU_FAN 1 的電源插槽,可能將會導致開機時 CPU 溫度過 熱並出現“Hardware monitoring errors”的資訊。 2.3.3 移除散熱器與風扇 請按照以下的步驟移除散熱器和風扇: 1. 先將主機板上連接 CPU 散熱器的電源 線從 CPU_FAN 上移除。 2. 將每個扣具上的旋鈕以逆時脈方向旋 轉,鬆開散熱器固定扣具。 3. 依照順序將扣具扳離主機板上的散熱器 插孔,採對角線方式移除,例如:先移 除 A,再移除 B;或是先移除 B,再移 除 A。 4.
2.3.4 安裝散熱器 Intel® LGA1151 處理器需要搭配安裝經過特殊設計的散熱器與風扇,方能得到最佳 的散熱效能。 • 請確認您使用合格的散熱器。 • 請在安裝散熱器與風扇之前確認 CPU 上面有塗上散熱膏。 1. 取下散熱器金屬片上的貼條,將金屬片放置在主機板的反面,并確認三個螺栓與 散熱器的三個螺絲孔相吻合。 2.
2.4 系統記憶體 2.4.1 概觀 本主機板組態有四組 DDR4(Double Data Rate,雙倍資料傳輸率)記憶體插槽。 DDR4 記憶體模組擁有與 DDR3 記憶體模組相同的外觀,但是實際上 DDR4 記憶體 模組的缺口與 DDR2、DDR3 記憶體模組不同,以防止插入錯誤的記憶體模組。DDR4 記憶體模組擁有更高的效能與更低的能耗。 下圖所示為 DDR4 DIMM 記憶體插槽在主機板上的順位元。 2.4.
2.4.3 安裝記憶體模組 加裝或移除記憶體或其他系統組件之前,請確認已拔除電源線,否則可 能會導致主機板與組件的嚴重損壞。 請依照下面步驟安裝記憶體模組: 1. 先將記憶體模組插槽一端的固定卡榫 扳開。 2. 將記憶體模組的金手指對齊記憶體模 組插槽的溝槽,並且在方向上要注意 金手指的缺口要對準插槽的凸起點。 記憶體模組插槽 向外掰開插槽兩端的 卡榫 插槽凸起點 由於 DDR4 記憶體模組金手指部份均有缺口設計,因此僅供以一個固定 方向安裝到記憶體模組插槽中。請勿強制插入以免損及記憶體模組。 3. 最後緩緩將記憶體模組插入插槽中, 若無錯誤,插槽一端的卡榫會因記憶 體模組置入而自動扣到記憶體模組兩 側的凹孔中。 卡榫會在記憶體模組正確安 裝後自動扣上 每次將記憶體模組垂直插入插槽以避免損壞插槽。 • 若安裝兩根以上的記憶體模組,請參考主機板包裝中的使用者指南。 • 請參考使用者指南中記憶體模組的合格供應商名單。 取出記憶體模組 請依照以下步驟取出記憶體模組: 1. 壓下記憶體模組插槽一端白色的固定 卡榫以鬆開記憶體模組。 2.
2.5 擴充插槽 考慮到未來會擴充系統機能的可能性,本主機板提供了擴充插槽,在接下來的子章 節中,將會描述主機板上這些擴充插槽的相關資訊。 安裝/移除任何介面卡之前,請暫時先將電腦的電源線拔出。如此可免除 因電氣殘留於電腦中而發生的意外狀況。 2.5.1 安裝介面卡 請依照下列步驟安裝介面卡: 1. 在安裝介面卡之前,請先詳讀該介面卡的使用說明,並且要針對該卡作必要的硬 體設定變更。 2. 鬆開電腦主機的機殼蓋並將之取出(如果您的主機板已放置在主機內)。 3. 找到一個您想要插入新介面卡的空置插槽,並以十字螺絲起子鬆開該插槽位元於 主機背板的金屬擋板的螺絲,最後將金屬擋板移出。 4. 將介面卡上的金手指對齊主機板上的擴充槽,然後慢慢地插入槽中,並以目視的 方法確認介面卡上的金手指已完全沒入擴充槽中。 5. 再用剛才鬆開的螺絲將介面卡金屬擋板鎖在電腦主機背板以固定整張卡。 6. 將電腦主機的機殼蓋裝回鎖好。 2.5.2 設定介面卡 在安裝好介面卡之後,接著還須透過軟體設定來調整該介面卡的相關設定。 1.
2.5.
2.5.4 PCI Express x8 插槽 (x8 Gen3 link) 板載的 PCIE7 插槽可提供一組 x16 Gen3 link 至處理器。這些插槽可支援伺服器等 級的多種高效能附加卡。 2.5.
2.5.7 安裝基板管理卡 請按照以下步驟將選購的 ASMB8 管理卡安裝到主機板上。 1. 找到主機板上的基板管理卡(Baseboard Management Card)插槽。 2.
2.6 內建指示燈 1. 電力指示燈(SBPWR1) 當主機板上內建的電力指示燈亮著時,表示目前系統是處於正常執行、省電模式或 者軟關機的狀態中,並非完全斷電。這個指示燈可用來提醒您在安裝或移除任何的硬 體裝置之前,都必須先移除電源,等待指示燈熄滅才可進行。請參考下圖所示。 2.
3. ME 指示燈(MELED1) 當 ME 指示燈閃爍時,表示 ME 正常工作。 4.
5.
2.7 跳線選擇區 1. CMOS 資料清除 (3-pin CLRTC1) 在主機板上的 CMOS 存儲器中記載著正確的時間與系統硬體組態等資料,這些資 料並不會因電腦電源的關閉而毀損資料的正確性,因為這個 CMOS 的電源是由主機 板上的鋰電池所供應。而使用 CLRTC 跳線可以清除這些系統硬體組態資料,但不會 影響系統時間和日期的準確性。 想要清除這些資料,可以依照下列步驟進行: 1. 關閉系統電源,拔掉電源適配器; 2. 將 CLRTC1 跳線帽由 [1-2](預設值)改為 [2-3] 約 5~10 秒鐘(此時即清除 CMOS 資料),再來再將跳線帽改回 [1-2]; 3. 插上電源適配器,開啟電源; 4.
2. VGA 控制器設定 (3-pin VGA_SW1) 此跳線可讓您開啟或關閉板載的顯示晶片控制器。將跳線設定為 [1-2] 短路為開啟 顯示晶片功能。 3.
4. ME 韌體強制回復設定(3-pin ME_RCVR1) 此跳線允許您在 ME 韌體崩潰時迅速進行回復。 5.
6. Smart Ride Through (SmaRT) 設定 (3-pin SMART_PSU1) 此跳線允許您開啟或關閉 Smart Ride Through (SmaRT) 功能。本功能用於提升系 統在重電源覆載模式下的穩定性,允許您在 AC 掉電期間維持系統的不中斷執行。當 AC 電壓準位過低時,內建於每個電源供應器中的快速 AC 掉電偵測電路會產生一個 SMBALERT# 訊號,在系統中開機節流條件。系統節流將降低系統記憶體與處理器的 頻寬,從而降低在 AC 線掉電期間的電源覆載。 7. DMLAN 設定(3-pin DM_IP_SEL1) 本跳線帽提供您選擇 DMLAN 設定。設定為 [2-3] 以強制 DMLAN IP 使用固定模式 (IP=10.10.10.10, submask=255.255.255.
8. SATA DOM 電源設定 (3-pin DOM1_PWR1) 此跳線允許您進行 DOM 電源設定。設為 [2-3] 以啟用 SATA4 支援功能。 9.
2.8 元件與週邊裝置的連接 2.8.1 後側面板連接埠 1. RJ-45 網路連接埠用於 iKVM:此連接埠僅當您安裝 ASMB8 管理卡時才有效。 2. Q-Code 指示燈:Q-Code 指示燈設計為採用 2 位元顯示,用來得知系統狀態。請 參考以下 Q-Code 列表來獲得更詳細的資訊。 3. 電源開關鈕:按下此鍵將打開系統。 4. VGA 連接埠:將 VGA 顯示器或 VGA 相容裝置連接至此連接埠。 5. RJ-45 網路連接埠 1-4:這些連接埠可經網路集線器連接至區域網路(LAN), 實現千兆連接。請參考下表中各燈號的說明。 6. USB 3.1 Gen 2 連接埠(1 和 2):這二組 4-pin 序列式匯流排(USB)連接埠可 連接兩台 USB 3.1 Gen 1 裝置。 7. USB 3.1 Gen 2 連接埠(5 和 6):這二組 4-pin 序列式匯流排(USB)連接埠可 連接一台 USB 3.
2.8.2 內部連接連接埠 1. Serial ATA 6.0Gbps 連接埠(7-pin SATA5-6 [灰色]) 這些連接埠由 Intel® C242 晶片所控制,可支援使用細薄的 Serial ATA 訊號線連接 Serial ATA 硬碟,最高資料傳輸速度可達 6Gb/s。若您安裝了 Serial ATA 硬碟,您可 以建立 RAID 0、RAID 1、RAID 10 或 RAID 5 設定。 實際的資料傳輸速度取決於所安裝的 Serial ATA 硬碟速度。 2.
3. USB 2.0 擴充套件排線插槽(10-1 pin USB1112; 4-pin Type-A USB7) 這些 USB 擴充套件排線插槽支援 USB 2.0 規格,將 USB 模組排線連接至任何一個 插槽,然後將模組安裝到機殼後側面板中開放的插槽。這些 USB 插槽與 USB 2.0 規 格相容,並支援傳輸速率最高達 480 MBps。 請勿將 1394 傳輸線與 USB 連接埠連接。此舉將會造成主機板損壞。 4. USB 3.1 Gen 1 擴充套件訊號線插座(20-1 pin USB3_34) 這些插槽用來連接額外的 USB 3.0 連接埠模組,並與 USB 2.0 規格相容。若您的 機殼提供有 USB 3.0 前面板排線,將該連線連接至本插槽,就可擁有前面板 USB 3.0 解決方案,支援傳輸速率最高達 5Gbps,可對 USB 充電裝置進行快速充電並優化能 效。 USB 3.1 Gen 1模組須另行購買。 連接的 USB 3.
5. 中央處理器、前面板與後面板風扇電源插座(4-pin FRNT_FAN1-3、REAR_FAN1、 CPU_FAN1) 支援冷卻風扇,您可以將風扇電源線連接到主機板上的風扇連接埠,請確認黑線需 接到風扇電源插座上的接地端(GND)。 • 千萬要記得連接風扇的電源,若系統中缺乏足夠的風量來散熱,那麼 很容易因為主機內部溫度逐漸昇高而導致當機,甚至更嚴重者會燒毀 主機板上的電子元件。 • 注意:這些插座並不是跳線!不要將跳線帽套在它們的針腳上。 • 所有的風扇都支援華碩風扇轉速控制技術。 6.
7. TPM 連接排針(14-1 pin TPM) 這組連接排針支援 T P M 系統,該系統能夠安全存儲按鍵,電子證書,密碼與資 料。同時,該系統也有助於提高網路安全,維護數位元身份(digital identities),保 證平臺完整。 8.
9. 序列埠連接插座 (10-1 pin COM1/COM2) 這個插座用來連接序列埠(COM)。將序列埠模組的訊號線連接至這個插座,接著 將該模組安裝至機殼后側面板空的插槽中。 10.
11. ATX 電源插座(24-pin EATXPWR1、8-pin EATX12V1) 這個插座為提供給 ATX 電源使用。由電源所提供的連接插頭已經過特別設計,僅 供以一個特定方向插入主機板上的電源插座。找到正確的插入方向後,僅需穩穩地將 之套進插座中即可。 • 請不要忘記連接 24+8-pin 電源插座,否則系統將不會開機。 • 如果您想要安裝其他的硬體裝置,請務必使用較高功率的電源供應器 以提供足夠的裝置用電需求。若電源供應器無法提供裝置足夠的用電 需求,則系統將會變得不穩定或無法開啟。 • 此主機板支援 ATX 2.
12. 系統控制台連接排針 (20-1 pin PANEL1) 這一組連接排針包括了數個連接到電腦主機前面板的功能接針。 1. 系統電源指示燈連接排針 (3-pin PLED) 這組排針可連接到電腦主機面板上的系統電源指示燈。在您開機電腦並且使用電 腦的情況下,該指示燈會持續亮著;而當指示燈閃爍亮著時,即表示電腦正處於 睡眠模式中。 2. 資訊指示燈連接排針 (2-pin MLED) 這組排針可將資訊指示燈的訊號線連接至前面板資訊指示燈。資訊指示燈顯示開 機狀態。開機過程中資訊指示燈會一直閃耀,直到進入系統。 3. 機殼喇叭連接排針 (4-pin SPEAKER) 這組四腳位元排針連接到電腦主機機殼中的喇叭。當系統正常開機便可聽到嗶嗶 聲,若開機時發生問題,則會以不同長短的音調來警示。 4. 硬碟動作指示燈連接排針 (2-pin +HDLED) 您可以連接此組 IDE_LED 接針到電腦主機面板上的 IDE 硬碟動作指示燈號,如此 一旦 IDE 硬碟有讀寫動作時,指示燈隨即亮起。 5.
13. 輔助系統控制台連接排針 (20-2 pin AUX_PANEL1, 20-pin AUX_PANEL2) 本組接針支援前面板上的多個功能,包括前面板 SMB,Locator LED 指示燈與開 關,機殼開啟警示連接排針,以及網路狀態指示燈。 1. 前面板 SMB 連接排針(6-1pin FPSMB) 這組連接排針可以讓您連接 SMB(系統管理匯流排)裝置。 2. 網路狀態指示燈(2-pin LAN1LINK 和 2-pin LAN2LINK) 這兩組 2-pin 排針可透過 Gigabit 網路指示燈排線來連接到 LAN 的狀態指示燈。 3. Locator 指示燈號連接排針(2-pin AUX_LOCLED1 和 2-pin AUX_LOCLED2) 這兩組 2-pin 排針為 Locator 指示燈號,透過 Locator LED 排線來連接。當您按 下 Locator 按鍵時,這個燈則會亮起顯示。 4.
14. 機殼開啟警示連接排針(2-pin INTRUSION1) 這組排針提供給設計有機殼開啟偵測功能的計算機主機機殼之用。此外,尚須搭 配一個外接式偵測裝置,如機殼開啟偵測感應器或者微型開關。在本功能啟用 時,若您有任何移動機殼元件的動作,感應器會隨即偵測到並且送出一訊號到這 組接針,最后會由系統記錄下來這次的機殼開啟事件。 本項目的預設值是將跳線帽套在 CHASSIS 排針中標示著“Chassis Signal”与 “GND”的兩個針腳上,若您想要使用本功能,請將跳線帽從“Chassis Signal” 与“GND”的針腳上移除。 15.
16. M.2 (NGFF) 卡插槽 (NGFF1 & NGFF2) 本插槽允許您安裝 M.2 裝置。 本插槽支援 PCI-E x2 與 SATA 連接埠的 2242/2260/2280/2210 型裝置。 M.2 (NGFF) 裝置為選購配備,需另行購買。 17.
2-38 第二章:硬體裝置資訊
第三章: 開啟電源 本章節說明開啟電腦電源的順序,以及 電腦開機後所發出各種不同類型嗶聲的代 表意義。 3
3.1 第一次開機電腦 1. 確認所有排線與接腳都接妥,然後蓋上機殼的外蓋。 2. 確定所有的開關都已關閉。 3. 將電源線接上機殼背面的電輸入插座。 4. 情況許可的話,最好將電源線路上加接突波吸收/保護器。 5. 您可以先開啟以下週邊裝置的電源: 6. a. 顯示器 b. 外接儲存裝置(從連接鏈中的最後一個裝置開始) c.
3.2 關閉電源 3.2.1 使用作業系統關閉功能 如果您使用的作業系統為 Windows® Server 2016: 1. 按下 +。 2. 點按螢幕右下角的電源圖示。 3. 選擇「關機」。 4. 從「關閉事件追蹤程式」中的選項欄選擇「其他(計劃)」,否則請選擇一選項 最能說明您希望關閉電腦的原因。 5. 點選「繼續」。 3.2.
3-4 第三章:開啟電源
第四章: BIOS 程式設定 在電腦系統中,BIOS 程式調校的優劣與 否和整個系統的執行效能有極大的關係。針 對您自己的配備來作最最佳化 BIOS 設定是 讓您的系統效能再提昇的關鍵。接下來本章 節將逐一說明 BIOS 程式中的每一項設定。 4
4.1 管理、更新您的 BIOS 程式 下列軟體讓您可以管理與更新主機板上的 BIOS(Basic Input / Output system)設 定。 1. ASUS CrashFree BIOS 3 2. ASUS EzFlash 當 BIOS 檔遺失或損壞時,可開機 USB 隨身碟來回復 BIOS 。 使用磁片或 USB 快閃記憶體盤更新 BIOS。 3. BUPDATER USB 開機盤在 DOS 模式下更新 BIOS。 上述軟體請參考相關章節的詳細使用說明。 建議您先將主機板原始的 BIOS 程式備份到 USB 隨身碟中,以備您往後 需要再度安裝原始的 BIOS 程式。使用 BUPDATER 來拷貝主機板原始的 BIOS 程式。 4.1.
4.1.2 使用華碩 EZ Flash 更新 BIOS 程式 華碩 EZ Flash 程式讓您能輕鬆地更新 BIOS 程式,可以不必再到作業系統模式下執 行。 從華碩網站上(tw.asus.com)下載最新的 BIOS 檔。 請依據以下步驟使用 EZ Flash 更新 BIOS: 1. 將含有最新 BIOS 檔的 USB 快閃記憶體盤插入 USB 連接埠。 2. 進入 BIOS 設定程式。來到 Tool 選單並選擇 ASUS EzFlash Utility 並按下 <Enter> 鍵將其開啟。 ASUS Tek.
4.1.3 使用 BUPDATER 更新 BIOS 程式 BUPDATER 程式讓您在 DOS 作業系統中,使用含有已更新的 BIOS 檔的 USB 開機 盤來更新 BIOS 程式。 以下 BIOS 畫面僅供參考。實際畫面可能會有所不同。 更新 BIOS 檔: 使用 BUPDATER 更新 BIOS 程式 1. 造訪華碩網站 tw.asus.com 下載最新主機板 BIOS 檔,并將其儲存在 USB 隨身碟 中。 2. 造訪華碩技術支援網站 tw.asus.com/support,複製 BUPDATER 程式 (BUPDATER. exe) 至您預先建立的 USB 開機盤。 3. 在 DOS 模式中開機系統,在提示符處輸入: BUPDATER /i[filename].CAP [filename] 為 USB 快閃記憶體盤中最新或最原始的 BIOS 檔名, 然後按下 。 A:\>BUPDATER /i[file name]CAP 4-4 第四章:BIOS 程式設定
4. BUPDATER 先確認檔,然後開始更新 BIOS。 ASUS Tek. EzFlash Utility Current Platform Platform : P11C-M/4L Version : 0201 Build date: 04/13/2018 Start Programming Flash. New Platform Platform : P11C-M/4L Version : 0206 Build date: 04/25/2018 DO NOT SHUTDOWN THE SYSTEM!!! Write 75% 當更新 BIOS 時請不要關閉或重啟系統,以防止系統開機失敗! 5. 當 BIOS 更新完畢后該程式會返回 DOS 指令。請從硬碟重新開機系統。 The BIOS update is finished! Please restart your system. C:\> 華碩 P11C-M/4L 主機板使用手冊 4-5
4.2 BIOS 程式設定 主機板擁有一片可編程的 LPC 晶片,您可以依照“4.
4.2.1 BIOS 程式選單介紹 選單項目 功能表列 設定值 線上操作說明 操作功能鍵 4.2.
4.2.3 選單項目 於功能表列選定選項時,被選擇的功能將會反白,假設您選擇 Main 功能,則會顯 示 Main 選單的項目。 點選選單中的其他項目(如:Event Logs、Advanced、Monitor、Boot、Tool 與 Exit 等)也會出現該項目不同的選項。 4.2.4 子選單 在選單畫面中,若功能選項的前面有一個小三角形標記,代表此為子選單,您可以 利用方向鍵來選擇,並且按下 鍵來進入子選單。 4.2.5 操作功能鍵說明 在選單畫面的右下方為操作功能鍵說明,請參照功能鍵說明來選擇及改變各項功 能。 4.2.6 一般說明 在選單畫面的右上方為目前所選擇的作用選項的功能說明,此說明會依選項的不同 而自動變更。 4.2.7 設定值 這些存在於選單中的設定值是提供給使用者選擇與設定之用。這些項目中,有的 功能選項僅為告知使用者目前運作狀態,並無法更改,那麼此類項目就會以淡灰色顯 示。而可更改的項目,當您使用方向鍵移動項目時,被選擇的項目以反白顯示,代表 這是可更改的項目。 4.2.
4.3 主選單(Main) 當您進入 BIOS 設定程式時,首先出現的第一個畫面即為主選單,內容如下圖。 4.3.1 System Date [Day xx/xx/xxxx] 設定您的系統日期。 4.3.
4.
4.4.
當 SGX Launch Control Policy 設為 [Locked] 時,以下項目才會出現。 SGX LE Public Key Hash 0-3 [0] 可讓您設定 Software Guard Extensions (SGX) Launch Enclave Public Key Hash 的字元數。 當 Software Guard Extensions (SGX) 設為 [Enabled] 時,以下項目才會出 現。 PRMRR Size [128MB] 可讓您設定 PRMMR 容量。 設定值有:[32MB] [64MB] [128MB] CPU Flex Ratio Override [Disabled] 本項目可讓您啟動或關閉 CPU Flex Ratio Override。設定值有:[Disabled] [Enabled] 當 CPU Flex Ratio Override 設為 [Enabled] 時,以下項目才會出現。 CPU Flex Ratio Settings [35] 可讓您設定 CPU Flex Ratio。 Hardware Prefetcher [Enabled]
4.4.
C-State Auto Demotion [C1 and C3] 本項目可讓您啟動或關閉 C-State 降級。設定值有:[Disabled] [C1] [C3] [C1 and C3]。 C-State Un-demotion [C1 and C3] 本項目可讓您啟動或關閉 C-State 不降級。設定值有:[Disabled] [C1] [C3] [C1 and C3]。 Package C state demotion [Disabled] 可讓您啟動或關閉 Package C state 降級。設定值有:[Disabled] [Enabled]。 Package C state Un-demotion [Disabled] 可讓您啟動或關閉 Package C state 降級。設定值有:[Disabled] [Enabled]。 Package C State limit [AUTO] 可讓您設定 Package C State 限制。設定值有:[C0/C1] [C2] [C3] [C6] [C7] [C7S] [CPU Default] [Auto] Thermal Monitor [
4.4.4 Trusted Computing Security Device Support [Enabled] 可讓您啟動或關閉 BIOS 安全裝置支援功能。設定值有:[Disabled] [Enabled]。 4.4.
4.4.
4.4.
Stop Bits [1] 停止位元為序列資料封包的終點(開始位元表示起始)。標準設定是 1 個停止 位元。使用較慢的裝置通訊可能會需要超過 1 個停止位元。設定值有:[1] [2]。 Flow Control [Hardware RTS/CTS] Flow control(流量控制)能預防在緩衝區溢滿時的資料流失。當傳送資料時, 若接收的緩衝區已經滿了,此時會送出“s t o p”(停止)訊號停止傳送資料流 (data flow)。當緩衝區空出時,會再送出“start”(開始)訊號以重新開始傳 送資料流。硬體流量控制使用兩條金屬線傳送 start/stop(開始/停止)訊號。設 定值有:[None] [Hardware RTS/CTS]。 VT-UTF8 Combo Key Support [Enabled] 可讓您啟動或關閉在 ANSI/VT100 終端器下所支援的 VT-UTF8 組合碼。設定 值有:[Disabled] [Enabled]。 Recorder Mode [Disabled] 若啟用此模式僅會傳送文字,此為擷取終端資料。設定值有:[D i s a b l e d] [Enabled
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Console Redirection [Disabled] 可讓您啟動或關閉控制台重新導向功能。設定值有:[Disabled] [Enabled]。 當 Console Redirection 設為 [Enabled] 時,以下項目才會出現。 Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) 可讓您透過序列埠遠 端遙控管理 Windows Server 系統。設定值有:[COM1] [COM2]]。 Terminal Type [VT-UTF8] 可讓您設定頻外管理的終端類型 。設定值有:[VT100] [VT100+] [VT-UTF8] [ANSI]]。 Bits per second [115200] 可讓您設定序列埠傳輸速度。設定值有:[9600] [192
4.4.11 PCI/PCIE Subsystem Settings(PCI/PCIE 子系統設定) Above 4G Decoding [Disabled] 若您的系統支援 64-b i t P C I 解碼能力,則可以啟用或關閉 64 位元運算能力的 裝置,來解碼超過 4G 以上的 Address Space(地址空間)。設定值有: [Disabled] [Enabled] SR-IOV Support [Disabled] 若您的系統擁有 SR-IOV 功能的 PCIe 裝置,此項目可讓您啟動或關閉 Single Root IO Virtualization 支援功能。設定值有:[Disabled] [Enabled] BME DMA Mitigation [Disabled] 此項目可讓您啟動或關閉 BME DMA Mitigation。設定值有:[Disabled] [Enabled] 4.4.
Legacy USB Support [Enabled] [Disabled] USB 裝置僅在 BIOS 設定程式中可用,在開機裝置列表中無法被識 別。 [Enabled] 啟動在較早作業系統中對 USB 裝置的支援。 [Auto] 系統在開機時偵測是否有無 USB 裝置。若有,會開啟 USB 控制器向 下相容模式。若沒有偵測到 USB 裝置,便會關閉 USB 向下相容功 能。 XHCI Hand-off [Enabled] [Disabled] 對於支援 XHCI 的作業系統,透過 XHCI 驅動程式支援 XHCI。 [Enabled] 對於不支援 XHCI 的作業系統,透過 BIOS 支援 XHCI。 USB Mass Storage Driver Support [Enabled] 本項目用來開啟或關閉 USB 大容量儲存裝置的驅動支援。設置值有:[Disabled] [Enabled]。 Port 60/64 Emulation [Enabled] 本項目可讓您開啟 I/O 連接埠 60h/64h 的支援。在無 USB 識別的作業系統中,本 項目必須開啟以完全支援 USB 鍵盤
4.4.
4.4.
Network / Storage / Video [Legacy] 本項目可讓您控制 UEFI 與 Legacy PXE/ Storage/ Video OpROM 的執行。設定 值有:[UEFI ] [Legacy]。 Other PCI devices [Legacy] 本項目決定除網路、儲存或影像之外裝置的 O p R O M 執行策略。設定值有: [UEFI ] [Legacy]。 4.4.14 NVMe Configuration(NVMe 設定) 若與 NVMe 裝置連接,您可以檢視 NVMe 控制器與磁碟資訊。 4.4.
4.4.16 Tls Auth 設定(Tls Auth Configuration) 本項目可讓您設定 Tls Auth。 4.4.
4.
4.6 晶片組設定(Chipset Configuration) 注意!在您設定晶片組設定選單時,不正確的數值將導致系統損毀。 4.6.
PEG Port Configuration PEG 0:1:0 Max Link Speed [Auto] 可讓您設定 Max Link Speed。設定值有:[Auto] [Gen1] [Gen2] [Gen3] PEG0 Slot Power Limit Value [75] 設定插槽電源上限。使用 <+> 或 <-> 調整數值。數值範圍從 0 至 255。 PEG0 Slot Power Limit Scale [1.0x] 可讓您選擇插槽電源限制數值的倍率。設定值有:[1.0x] [0.1x] [0.01x] [0.
VT-d [Enabled] 可讓您啟動北橋晶片上的虛擬技術功能。設定值有:[Enabled] [Disabled]。 CRID Support [Disabled] 可讓您啟動或關閉 CRID control for Intel SIPP。設定值有:[Disabled] [Enabled] Above 4GB MMIO BIOS Assignment [Disabled] 可讓您啟動或關閉超過 4GB MemoryMappedIO BIOS 指定。當容量設為 2048 MB 時,此功能會自動關閉。設定值有:[Enabled] [Disabled]。 當 VT-d 設為 [Enabled] 時,以下項目才會出現。 X2APIC Opt Out [Disabled] 可讓您啟動或關閉 X2APIC Opt Out。設定值有:[Disabled] [Enabled] 華碩 P11C-M/4L 主機板使用手冊 4-29
4.6.
4.7 Security Menu(安全選單) 此選單允許建立一個新密碼或更改現有密碼,開啟或關閉安全啟動狀態,也讓使用 者自行設定系統模式狀態。 Administrator Password(設定系統管理員密碼) 當您設定系統管理員密碼後,建議您先登入您的帳戶,以免 BIOS 設定程式中的某 些資訊無法檢視或變更設定。 請依照以下步驟設定系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3.
User Password(設定使用者密碼) 當您設定使用者密碼後,你必需登入您的帳戶才能使用 BIOS 設定程式。使用者密 碼的預設值為 Not Installed,當您設定密碼後將顯示 Installed。 請依照以下步驟設定使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3. 由 Create New Password 視窗輸入新密碼,輸入完成按下 。 4. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟刪除使用者密碼(User Password): 1.
Restore Factory Keys 此項目將強迫系統進入 User Mode,並安裝出廠預設安全開機金鑰資料。 Reset to Setup Mode 此項目將會刪除 NVRAM 中的所有開機金鑰資料。 Key Management 本項目僅當 Secure Boot Mode 設定為 [Custom] 時才會顯示,提供您修改 Secure Boot(安全開機)變量與設定 Key Management(密鑰管理)頁面。 Factory Key Provision [Disabled] 本項目可以在系統為 S e t u p M o d e 時提供您系統預設安全啟動變量。設定值 有:[Disabled] [Enabled] Restore Factory keys 本項目會安裝所有系統預設安全變量。 Reset to Setup Mode 本項目僅當您設定原廠預設金鑰時才會出現。本項目可以讓您刪除所有金鑰回 復 Setup Mode。 Export Secure Boot Variables 本項目會詢問您是否要儲存所有安全啟動變量。選擇 Y e s 以儲存,或是選擇 No 放棄。 Enro
Device Guard Ready Remove‘UEFI CA’from DB 由 Secure Boot DB 移除 Microsoft UEFI CA。 Restore DB defaults 將 DB variable 還原為出廠預設值。 Platform Key (PK) 設定值有:[Details] [Export] [Update] [Delete] Key Exchange Keys (KEK) / Authorized Signatures (DB) / Forbidden Signatures (DBX) 設定值有:[Erase] [Set New] [Save to File] Authorized TimeStamps (DBT) / OsRecovery Signatures 設定值有:[Update] [Append] 4.
Boot Option Priorities 這些項目讓您從所有可用裝置中指定開機磁碟的優先層級。螢幕上顯示的裝置數量 根據系統中所安裝的裝置而定。 • 欲選擇開機裝置,請在 ASUS 圖示出現時按下 。 • 若要以安全模式進入 Windows ® 作業系統,請在開機自我檢測完成 後,按下 。 Fast Boot [Disabled] 可讓您啟動或關閉全螢幕顯示個人化開機畫面功能。設定值有:D i s a b l e d] [Enabled] 當 Quiet Boot 設為 [Disabled] 時,以下項目才會出現。 Sata Support [All Sata Devices] [Last Boot HDD Only] 只有前一次的開機硬碟裝置可以在開機自檢時運 作。 [All Sata Devices] 所有 SATA 裝置皆可在作業系統下與開機自檢時 運作。 VGA Support [EFI Driver] [Auto] Legacy 作業系統只有 legacy OpRom,同時商標將不會再開機自 檢時出現。 [EFI Driver] Efi 驅動程式仍會安裝於 EFI
4.
4.10 工具選單(Tool) 工具選單可以讓您針對特別功能進行設定。請選擇選單中的選項並按下 鍵 來顯示子選單。 ASUS EZ Flash 本項目可以讓您執行 Start EzFlash 工具程式,若要了解更多的細節,請參考 5.1.2 使用華碩 EzFlash 更新 BIOS 程式 的說明。 4.11 事件記錄選單(Event Log menu) 本選單提供您變更事件記錄設定與檢視系統事件記錄。 4.11.
When Log is Full [Do Nothing] 當 Smbios Event Los 設定為 [Enabled] ,而且事件記錄(event log)存滿了時,本 項目可以提供您設定做如何反應。設定值有:[Do Nothing] [Erase Immediately]。 Smbios Event Log Standard Settings Log System Boot Event [Disabled] 允許您開啟或關閉登入系統啟動事件。設定值有:Disabled] [Enabled] MECI [1] 允許您調整 M E C I 的設定值。使用 <+> 或 <-> 鍵調整數值。設定值有:[1] [255]。 METW [60] 允許您調整 M E T W 的設定值。使用 <+> 或 <-> 鍵調整數值。設定值有:[0] [99]。 Custom Options Log EFI Status Code [Disabled] 允許您開啟或關閉 EFI 狀態編碼記錄。設定值有:[Disabled] [Enabled]。 當 Log EFI Status Code 設為 [Enabled] 時,
4.
OS Watchdog Timer [Disabled] 若本項目啟用時,啟動的 BIOS 計時器僅能透過作業統載入後的 Intel Management 軟體進行關閉。設定值有:[Enabled] [Disabled] 以下的項目僅當 OS Watchdog 設定為 [Enabled] 時才會顯示。 OS Wtd Timer Timeout [10 minutes] 本項目可讓您設定作業系統啟動的時間長短本項目提供您設定 O S B o o t Watchdog Timer(開機關門狗計時器)。設定值有:[5 minutes] [10 minutes] [15 minutes] [20 minutes] OS Wtd Timer Policy [Reset] 本項目可讓您在 OS Boot Watchdog Timer 到期後,提供您設定系統應該如何回 應。設定值有:[Do Nothing] [Reset] [Power Down] Serial Mux [Disabled] 啟用或關閉 Serial Mux 設定。設定值有:[Disabled] [Enabled] BMC Warm Reset 本項
Enabling/Disabling Options SEL Components [Enabled] 在開機過程時,啟用或關閉所有事件記錄(Event Logging)功能。設定值有:[No] [Yes, On next reset] [Yes, On every reset]。 • 以下的項目僅當 SEL Components 設定為 [Enabled] 時才會顯示。 • 所有變更的數值將會於重新開機後才套用。 Erasing Settings Erase SEL [No] 本項目可讓您清除系統事件記錄的選項,設定值有:[No] [Yes, On next reset] [Yes, On every reset]。 When SEL is Full [Do Nothing] 本項目可讓您選擇當系統事件記錄滿載時的動作,設定值有:[D o N o t h i n g] [Erase Immediately]。 Log EFI Status Codes [Error code] 本項目可關閉載入 EFI 狀態編碼,或僅載入錯誤編碼,或僅載入前行編碼,或 兩者都載入。設定值有:[Disabled] [Bo
4.12.
當 IPV6 Support 設為 [Enabled] 時,以下項目才會出現。 Configuration Address source [Unspecified] 選擇設定的網路通道的參數為靜態或動態(透過 B I O S 或 B M C)。未指定選項 將不會修改在 BIOS 裡的任何 BMC 網路參數。設定值有:[Unspecified] [Static] [DynamicBmcDhcp] Shared LAN IPV6 Support [Enabled] 可讓您啟動或關閉 LAN2 IPV6 支援。設定值有:[Disabled] [Enabled] 當 IPV6 Support 設為 [Enabled] 時,以下項目才會出現。 Configuration Address source [Unspecified] 選擇設定的網路通道的參數為靜態或動態(透過 B I O S 或 B M C)。未指定選項 將不會修改在 BIOS 裡的任何 BMC 網路參數。設定值有:[Unspecified] [Static] [DynamicBmcDhcp] 4.12.
4.
第五章: RAID 磁碟陣列設定 在本章節中,我們將介紹伺服器內所支 援的磁碟陣列的設定與說明。 5
5.1 RAID 功能設定 本伺服器主機板支援以下 RAID 設定: 主機板具備 Intel® C242 晶片,本主機板可支援以下 SATA RAID 方案:Intel® Rapid Storage Technology enterprise Option ROM 工具程式支援 RAID 0、RAID 1、RAID 10 與 RAID 5 (適用於 Windows 與 Linux 作業系統)。 5.1.
5.1.2 安裝硬碟 本主機板支援 Serial ATA 硬碟。為了最佳的效能表現,當您要建立陣列模式設定 時,請盡可能採用具備相同型號與容量的硬碟。 請依照以下安裝方式來建構 SATA RAID 磁碟陣列: 1. 按照說明將 SATA 硬碟安裝至硬碟槽中。 2. 將 SATA 訊號線連接到 SATA 硬碟背部的訊號線連接埠。 3. 將 SATA 電源線連接到 SATA 硬碟背部的電源連接埠。 5.1.3 設定 BIOS 中的 RAID 選項 在開始建立 RAID 陣列前,您必須先在 BIOS 程式中對連接到由 Intel® C242 晶片 組支援的 SATA 連接埠的 SATA 硬碟進行 RAID 設定。請依照下列步驟進行操作︰ 1. 在開機自我偵測(POST)過程中進入 BIOS 設定界面。 2. 進入進階選單(Advanced)後,選擇 SATA Configuration 選項,然後按 。 3. 將 SATA Mode 項目設定為 [RAID]。 4.
5.2 I ntel ® Rapid Storage Technology enterprise SATA Option ROM 工具程式 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程式 可透過主 機板上內建的南橋晶片所連接的 SATA 硬碟來建立 RAID 0、RAID 1、RAID10 (RAID 1+0) 和 RAID 5 陣列設定。 執行前請確保安裝了 Serial ATA 硬碟驅動,正確的主機板跳線設定,在 BIOS 設定中設定了正確的 SATA 模式。您可以參考“5.1.2 安裝硬碟”、 “5.1.3 設定 BIOS 中的 RAID 選項”。 執行 Inte® Rapid Storage Technology enterprise SATA Option ROM utility: 1. 打開系統。 2. 開機自我偵測時請按下 + 以顯示主選單程式。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.
5.2.1 建立 RAID 陣列 請依照以下步驟建立 RAID: 1. 從程式主選單中,選擇 1. Create RAID Volume,然後按下 。此時將出現以 下畫面。 2. 在下方畫面為 RAID 陣列輸入一個名字並按下 鍵。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Strips) Disks: Select Disks Strip Size: 128KB Capacity: 0.0 GB Syne: N/A Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less.
6. 按下向上/向下箭頭按鍵以選擇 RAID 磁碟陣列要分割的容量(僅 RAID 0、RAID 10、RAID 5),然後按下 鍵。分割的數值可由 4KB 遞增至 128KB。數 值為: RAID 0:128KB RAID 10:64KB RAID 5:64KB 若此系統欲作為伺服器使用,建議您選擇較低的磁區大小;若此系統欲 作為多媒體電腦用來執行影音的編輯製作,建議您選擇較高的磁區大小 來獲得最佳的效能。 7. 選擇 Capacity 項目,輸入您所要的陣列容量,接著按下 按鍵。本項目預 設值是採用最高可容許的磁碟容量。 8. 在 Create Volume 的提示對話框中再按下 按鍵來建立磁碟陣列。 9. 在下方的警示視窗中按下 建立陣列並返回主選單,或按下 返回 CREATE VOLUME(建立容量)選單。 WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
5.2.2 移除 RAID 磁區 在操作此功能時請務必非常小心,所有在硬碟中的資料將被一併移除。 請依照以下步驟移除磁區: 1. 從程式主選單中,選擇 2. Delete RAID Volume,然後按下 鍵。 2. 從 Delete Volume 選單按下向上/向下箭頭鍵以選擇您要移除的 RAID 陣列並按下 鍵。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.2.3 重新設定硬碟為非陣列硬碟 請注意!當您將 RAID 陣列硬碟設定為無 RAID 陣列狀態時,所有磁碟陣 列中的資料與陣列本身的構造資料都將被移除。 請依照以下步驟重新設定非陣列硬碟: 1. 從程式主選單中,選擇 3. Reset Disks to Non-RAID,然後按下 鍵。 2. 按下向上/向下箭頭鍵以選擇您要重新設定的硬碟,確認後請按下空格鍵。接著被 選定的硬碟裝置旁便會出現一個小三角形圖示。當所有要進行陣列設定的硬碟裝 置選擇完畢後,請按下 鍵。 [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk. WARNING: Resetting a disk causes all data on the disk to be lost.
5.2.4 退 出 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程式 請依照以下步驟退出程式: 1. 從程式主選單中,選擇 4. Exit 然後按下 。 2. 按下 退出,或按下 回到程式主選單。 [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 5.2.5 重建 RAID 本選項僅適用於 RAID 1 陣列。 使用未設定 RAID 的硬碟重建 RAID 陣列 若任何包含 RAID 1 陣列的 SATA 硬碟失敗,系統在 POST 過程中顯示 RAID volume 的 狀態為“Degraded”。您可使用其他沒有設定 RAID 的硬碟重建 RAID 陣列。 請依照以下步驟使用未設定 RAID 的硬碟重建 RAID 陣列: 1. 提示出現時,按下 + 進入 Intel Rapid Storage Technology 工具程式。 2.
3. 選擇硬碟後程式自動開始重建。RAID volume 的狀態變為“Rebuild”。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume RAID Volumes: ID Name 1 Volume0 [ MAIN MENU ] 3. Reset Disks to Non-RAID 4. Exit [ DISK/VOLUME INFORMATION] Level1 RAID1(Mirror) Physical Devices: Port Drive Model 1 ST3160812AS 2 ST3160812AS Strip N/A Serial # 9LS0F4HL 3LS0JYL8 Size 149.0GB Size 149.0GB 149.
5.2.6 設定 BIOS 設定程式中的開機陣列 當使用 Intel® Rapid Storage Technology 建立 multi-RAID 時,您可以為 RAID 陣列 設定 BIOS 中的開機優先級。 請依據以下步驟設定開機陣列: 請設定至少一個開機陣列。 1. 重啟系統並在 POST 過程中按下 進入 BIOS。 2. 點選 Boot 選單,選擇 Boot Device Priority 項目。 3. 使用上/下方向鍵選擇開機優先級,然後按下 鍵。更多資訊請參考第四章中 “開機裝置順序”部分的說明。 4. 在 Exit 選單中選擇 Save Changes & Exit,然後按下 鍵。 5.
5.3 I ntel® Rapid Storage Technology enterprise 工具程式 (Windows) Intel® Rapid Storage Technology enterprise 工具程式透過南橋晶片的支援,可讓您 使用連接到主機板上 Serial ATA 連接埠上的 Serial ATA 硬碟建立 RAID 0、RAID 1、 RAID 10(RAID 1+0) 與 RAID 5 的陣列設定。 您需要在 Windows® 作業系統中手動安裝 Intel® Rapid Storage Technology enterprise。請參考第六章的安裝說明。 在 Windows® 作業系統下進入 Intel® Rapid Storage Technology enterprise: 1. 開啟系統進入 Windows 桌面。 2.
5.3.1 建立 RAID 陣列 請依照以下步驟建立 RAID: 1. 從程式主選單中,選擇 Create Volume,並選擇陣列類型。然後點選 Next。 2. 為您的 RAID 磁區鍵入一個名稱,然後選擇陣列磁碟。 3. 選擇 Volume Size 標籤頁,您可以拖曳滑塊調整陣列容量。 4.
5.
5.3.2 變更陣列類型 建立 RAID 陣列完成後,您可以在 Volume Properties 區域檢視相關項目的設定。 按照以下步驟變更陣列類型: 1. 在 Volume 區域點選您要變更的 SAS / SATA 陣列項目。 2 在 Volume Properties 區域選擇 Type:RAID 1 Change type。 3. 您可以變更名稱,選擇新陣列類型,若有必要還可以選擇要包含到新陣列中的磁 碟。 4.
5.3.3 移除陣列 移除陣列時請注意。硬碟上的資料將會毀損,請先備份資料。 按照以下步驟移除陣列: 1. 從程式主選單中,在 Volume 區域選擇您要移除的陣列 (如 Volume_0000)。 2. 在 Volume Properties 區域選擇 Delete volume,出現以下畫面。 3.
5.3.
5-18 第五章:RAID 磁碟陣列設定
第六章: 安裝驅動程式 在本章節中,我們將介紹主機板所支援的 相關驅動程式的安裝與設定說明。 6
6.1 安裝 RAID 驅動程式 當您在系統中建立好 RAID 陣列模式後,就可以開始安裝作業系統至獨立的硬碟裝 置或具開機功能的陣列上。本章節將介紹如何在安裝作業系統的過程中,控制 RAID 的驅動程式。 6.1.1 建立搭載 RAID 驅動程式的 USB 隨身碟 安裝 Windows® Server 作業系統時,您可以由 USB 隨身碟載入 RAID 驅動程式。請 將文件由驅動及公用程式光碟複製至 USB 隨身碟。 在 Windows® 中建立搭載 RAID 驅動程式的 USB 隨身碟: 1. 在光碟機中放入本系統/主板的驅動及公用程式光碟。 2. 將 USB 隨身碟連接電腦。 3. 開啟驅動及公用程式光碟。 4. 點選 Drivers > C24x INTEL RAID > Driver > Windows,將 SATA_RAID 資料夾複 製至 USB 隨身碟。 6.1.
3. 接著請點選 Load Driver。 4. 然後顯示訊息,提醒您放入 RAID 控制器驅動程式檔案。若您的系統裡有僅只有 一部光碟機,請先將 Windows 作業系統安裝光碟退出,並放入驅動與公用程式 DVD 光碟,然後點選 Browse(瀏覽)。 5. 找到存放在驅動與公用程式光碟內的驅動程式,然後點選 OK 繼續。 6.
6-4 7. 當系統載入 R A I D 驅動程式後,請取出主機板驅動與公用程式光碟 並再放 入 Windows Server 作業系統安裝光碟,選擇驅動程式安裝至 Windows 並點選 Next。 8.
6.2 安裝應用程式與工具程式 本驅動及公用程式光碟裡提供您主機板相關的驅動程式、管理應用程式與工具程 式,可以讓您將主機板功能最佳化。 1. 驅動及公用程式 DVD 光碟裡的內容如有變更,恕不另行通知。請造 訪華碩網站(tw.asus.com)以更新最新的軟體與工具程式。 2. 驅動及公用程式 DVD 光碟為支援使用於 Windows® Server 2012 R2 R2 和 Windows® Server 2016 作業系統。 6.3 使用驅動及公用程式 DVD 光碟 於光碟機中放入主機板/系統的驅動程式光碟。若您已經啟動光碟自動偵測的功 能,透過作業系統自動偵測的功能,接著會自行啟動光碟並顯示預設的 Drivers (驅 動程式)標籤頁。 若視窗並未自動出現,那麼請瀏覽驅動及公用程式 D V D 光碟的檔案內 容,找到 BIN 目錄中的 ASSETUP.EXE 程式,並點選 ASSETUP.
6.4 安裝系統驅動程式 本章節為如何安裝系統驅動程式的說明。在 Windows® 作業系統中,您將需要手動 安裝系統驅動程式。 請依照下列步驟安裝系統驅動程式: 1. 重新開機,並使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光碟機中放入主機板/系統所附的應用程式與驅動程式光碟片, 若您的系統已經開機了光碟機“自動安插通知”的功能,那麼稍後一會光碟片會 自動顯示 Drivers 選單(驅動程式選單)視窗。 若您的系統未開機光碟機“自動安插通知”的功能,請瀏覽光碟片的檔 內容,找到 Setup.exe 檔案,並雙按 Setup.exe 執行光碟。 6-6 3. 勾選您要安裝的驅動程式,然後選擇 安裝。 4.
5.
6-8 第六章:安裝驅動程式
附錄 A
P11C-M/4L 架構圖 A-2 附錄:相關資訊
Q-Code 列表 Action PHASE POST CODE TYPE DESCRIPTION 0x1 Progress First post code 0x2 Progress Load BSP microcode 0x3 Progress Perform early platform Initialization 0x4 Progress Set cache as ram for PEI phase 0x5 Progress Establish Stack 0x6 Progress CPU Early Initialization 0x10 Progress PEI Core Entry 0x11 Progress PEI cache as ram CPU initial 0x15 Progress NB Initialization before installed memory 0x19 Progress SB Initialization before installed memory 0xB0 MRC Progress
Action A-4 PHASE POST CODE TYPE DESCRIPTION 0x90 Progress BDS started 0x91 Progress Connect device event 0x92 Progress PCI Bus Enumeration 0x93 Progress PCI Bus Enumeration 0x94 Progress PCI Bus Enumeration 0x95 Progress PCI Bus Enumeration 0x96 Progress PCI Bus Enumeration 0x97 Progress Console outout connect event 0x98 Progress Console input connect event 0x99 Progress AMI Super IO start 0x9A Progress AMI USB Driver Initialization 0x9B Progress AMI USB Driver Initi
華碩的聯絡資訊 華碩電腦公司 ASUSTeK COMPUTER INC.(台灣) 市場訊息 地址 電話 傳真 網址 :台灣臺北市北投區立德路 150 號 4 樓 :+886-2-2894-3447 :+886-2-2890-7798 :http://www.asus.com/tw/ 技術支援 電話 線上支援 :+886-2-2894-3447(0800-093-456) : https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=zh-tw ASUS COMPUTER INTERNATIONAL(美國) 市場訊息 地址 傳真 網址 :48720 Kato Rd., Fremont, CA 94538, USA :+1-510-608-4555 :http://www.asus.com/us/ 技術支援 電話 傳真 線上支援 :+1-812-282-2787 :+1-812-284-0883 : https://www.asus.
華碩電腦(上海)有限公司 ASUSTEK COMPUTER(SHANGHAI)CO., LTD. 市場訊息 地址 電話 傳真 網址 : 上海市閔行區金都路 5077 號 :+86-21-5442-1616 :+86-21-5442-0099 :http://www.asus.com.cn 技術支援 電話 線上支援 :+86-20-2804-7506(400-620-6655) : https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=zh-cn ASUS Czech Service s.r.o.(歐洲) 市場訊息 地址 Republic 傳真 網址 :Na Rovince 887, 720 00 Ostrava – Hrabová, Czech :+420-596766888 :http://www.asus.
ASUS Holland BV(荷蘭) 市場訊息 地址 網址 :Marconistraat 2, 7825GD EMMEN, The Netherlands :http://www.asus.com/nl/ 技術支援 電話 傳真 電子信箱 線上支援 :+31-(0)591-5-70292 :+31-(0)591-666853 :advance.rma.eu@asus.com : https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=nl-nl ASUS Polska Sp. z o.o.(波蘭) 市場訊息 地址 網址 :Ul. Postępu 6, 02-676 Warszawa, Poland :http://www.asus.com/pl/ 技術支援 電話 線上支援 :+48-225718033 : https://www.asus.
A-8 附錄:相關資訊