Motherboard P8B-M series
E7387 First Edition May 2012 Copyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Contents....................................................................................................... iii Notices......................................................................................................... vii Federal Communications Commission Statement............................ vii Canadian Department of Communications Statement...................... vii REACH ...........................................................................................
Contents 2.4 System memory.......................................................................... 2-16 2.4.1 Overview........................................................................ 2-16 2.4.3 Installing a DIMM........................................................... 2-17 2.4.2 2.5 2.4.4 2.5.1 Installing an expansion card.......................................... 2-18 2.5.3 Interrupt assignments.................................................... 2-19 2.5.4 2.5.5 2.5.6 2.5.7 2.7 2.
Contents 4.2.6 General help.................................................................... 4-9 4.2.8 Pop-up window................................................................ 4-9 4.2.7 4.3 4.2.9 4.5 4.3.1 System Date [Day xx/xx/xxxx]........................................ 4-10 4.3.3 Security.......................................................................... 4-10 Advanced menu.......................................................................... 4-14 4.5.1 ACPI Settings.....
Contents 5.2.2 Adding or viewing a RAID configuration........................ 5-12 5.2.4 Rebuilding failed drives.................................................. 5-17 5.2.3 5.2.5 5.2.6 5.2.7 5.2.8 Initializing the virtual drives............................................ 5-13 Checking the drives for data consistency...................... 5-19 Deleting a RAID configuration........................................ 5-22 Selecting the boot drive from a RAID set.......................
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Safety information Electrical safety • • • • • • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
About this guide This user guide contains the information you need when installing and configuring the motherboard. How this guide is organized This user guide contains the following parts: • • • • • • • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technologies it supports. Chapter 2: Hardware information This chapter lists the hardware setup procedures that you have to perform when installing system components.
Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
P8B-M series specifications summary Processor Support / System Bus Core Logic Form Factor ASUS Features Fan Speed Control Rack Ready (Rack and Pedestal dual use) ASWM Enterprise Memory Total Slots Capacity Memory Type Expansion Slots (follow SSI Location #) P8B-M P8B-MX 1 x Socket LGA1155 Intel® Xeon® E3-1200 Processor v2 Family Intel® Xeon® E3-1200 Processor Family Intel® Core™ i3-2100 Processor Family Intel® Pentium™ G8x0/G6x0 Intel® Celeron™ G5x0/G4x0 Intel® C204 Chipset Intel® C202 Chipset Micro ATX,
P8B-M series specifications summary Onboard I/O Connectors Rear I/O Connectors Management Solution Monitoring Environment TPM Header PSU Connector USB Connectors Fan Header SMBus Chassis Intruder Serial Port Header External Serial Port External USB Port VGA Port RJ-45 PS/2 KB/Mouse Software Out of Band Remote Management CPU Temperature FAN RPM 1 24-pin ATX power connector + 8-pin ATX 12V power connector 1 x USB connector (Type A USB socket) 2 x USB pin header (up to 4 devices) 5 x 4pin 1 1 1 1 2 1 2 + 1
This chapter describes the motherboard features and the new technologies it supports.
Chapter summary 1 1.1 Welcome!....................................................................................... 1-3 1.3 Serial number label....................................................................... 1-4 1.2 1.4 Package contents.......................................................................... 1-3 Special features.............................................................................
1.1 Welcome! Thank you for buying an ASUS® P8B-M series motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard, and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items.
1.3 Serial number label For faster and quicker troubleshooting solutions from the ASUS Technical Support team, provide the product’s serial number containing 12 characters such as xxS2xxxxxxxx as shown in the figure below. P8B-M xxS2xxxxxxxx 1.4 Special features 1.4.
DDR3 memory support The motherboard supports the 2-channel DDR3 memory that features data transfer rates of DDR3 1600*/ 1333 / 1066 MHz to boost the system’s performance, and to meet the higher bandwidth requirements of server and workstation applications. The 2-channel DDR3 architecture also manages traffic with bandwidth of up to 21GB/s, and reduces voltage thus reducing power usage and heat generation. *D DR3 1600 can only be supported with Intel® Xeon® E3-1200 v2 Processor. PCI Express® 3.
USB 2.0 technology The motherboard implements the Universal Serial Bus (USB) 2.0 specification, dramatically increasing the connection speed from the 12 Mbps bandwidth on USB 1.1 to a fast 480 Mbps on USB 2.0. USB 2.0 is backward compatible with USB 1.1. Temperature, fan, and voltage monitoring The CPU temperature is monitored to prevent overheating and damage. The system fan rotations per minute (RPM) is monitored for timely failure detection.
This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard.
Chapter summary 2 2.1 Before you proceed...................................................................... 2-3 2.3 Central Processing Unit (CPU).................................................. 2-10 2.2 2.4 2.5 2.6 2.7 Motherboard overview.................................................................. 2-5 System memory.......................................................................... 2-16 Expansion slots...........................................................................
2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them.
Onboard LEDs 1. 2. Standby Power LED (SB_PWR1) The motherboard comes with a standby power LED. The green LED lights up to indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard LED. BMC LED (BMC_LED1) The green heartbeat LED blinks per second to indicate that the ASMB5 is working normally.
2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an ATX 1.1 compliant chassis. Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.
2.2.
2.2.
2.2.5 Layout contents Slots/Soocket Page 1. CPU sockets 2-10 2. DDR3 sockets 2-16 3. PCI Express x8 / PCI Express x16 / PCI slots 2-18 Jumpers 2-8 Page 1. Clear RTC RAM (CLRTC1) 2-22 2. VGA controller setting (3-pin VGA_SW1) 2-23 3. CPU Fan and Chassis Fan control setting (3-pin CPUFAN_SEL1, CHAFAN_SEL1) 2-23 4. LAN controller setting (3-pin LAN_SW1, LAN_SW2) 2-24 5. RAID configuration utility selection (3-pin RAID_SEL1) 2-24 6.
Internal connectors 1. Serial ATA connectors (SATA 6Gb/s: 7-pin SATA1, SATA2 [Blue]) (SATA 3Gb/s: 7-pin SATA3, SATA4, SATA5, SATA6 [Black]) Serial ATA connectors (SATA 3Gb/s: 7-pin SATA1-6 [Black]) 2. Hard disk activity LED connector (4-pin HDLED1) 3. USB connector (10-1 pin USB34, USB56; A-Type USB7) 4. CPU, front and rear fan connectors (4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1) 5. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) 6.
2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA1155 socket designed for the Intel® Xeon E3-1200 v2/Core™ i3-2100 processor. 2.3.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related.
3. Lift the load lever in the direction of the arrow until the load plate is completely lifted. Load plate 4. Remove the PnP cap from the CPU socket by lifting the tab only. PnP cap Cap tab 5. Position the CPU over the socket, ensuring that the gold triangle is on the bottom‑left corner of the socket, and then fit the socket alignment keys into the CPU notches. The CPU fits in only one correct orientation.
6. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer. Some heatsinks come with preapplied thermal paste. If so, skip this step. The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off immediately, and seek professional medical help. 7.
2.3.2 Installing the CPU heatsink and fan The Intel LGA1155 processor requires a specially designed heatsink and fan assembly to ensure optimum thermal condition and performance. ® • When you buy a boxed Intel® processor, the package includes the CPU fan and heatsink assembly. If you buy a CPU separately, ensure that you use only Intel®‑certified multi‑directional heatsink and fan. • Your Intel® LGA1155 heatsink and fan assembly comes in a push-pin design and requires no tool to install.
3. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector. 2.3.3 Uninstalling the CPU heatsink and fan To uninstall the CPU heatsink and fan: 1. 2. 3. 4. 2-14 A Disconnect the CPU fan cable from the connector on the motherboard. Rotate each fastener counterclockwise.
2.3.4 Installing the CPU heatsink in rack The Intel 1155 processor requires a specially designed heatsink to ensure optimum thermal condition and performance. ® • • Ensure that you use qualified heatsink assembly only. Ensure that you have applied the thermal interface material to the top of the CPU before installing the heatsink and fan. 1. Peel off the sticker on the heatsink metal plate and affix the plate to the back of the motherboard, matching the standoffs to the heatsink screw holes. 2.
2.4 System memory 2.4.1 Overview The motherboard comes with four Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets. A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched differently to prevent installation on a DDR2 DIMM socket. DDR3 modules are developed for better performance with less power consumption. 2.4.
2.4.3 Installing a DIMM Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. 2. DIMM notch Press the retaining clip outward to unlock a DIMM socket. Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket. 1 2 1 DIMM slot key Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction.
2.5 Expansion slots Unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1. 2. 3. 4. 5. 6. Before installing the expansion card, read the documentation that came with it and make the necessary hardware settings for the card. Remove the system unit cover (if your motherboard is already installed in a chassis).
2.5.
PCI slot PCIe x8 slot (x4 link) PCIe x16 slot (x16 link) PCIe x8 slot (x4 link) (P8B-M only) 2.5.7 Installing ASMB5 management card Follow the steps below to install an optional ASMB5 management card on your motherboard. 2-20 1. Locate the BMC_FW header on the motherboard. 2. Orient and press the ASMB5 management card in place.
2.5.8 Connecting the thermal sensor cable Follow the steps below to connect the thermal sensor cable to the connector on your motherboard. 1. Locate the TR1 connector on the motherboard. 2. Connect the thermal sensor cable to the connector. 3. Place the other end of the thermal sensor cable to the device you would like to monitor temperature.
2.6 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. 2. 3. 4. Turn OFF the computer and unplug the power cord. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. 3. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. CPU Fan and Chassis Fan control setting (3-pin CPUFAN_SEL1, CHAFAN_SEL1) These jumpers allow you to switch for fan pin selection. The CPUFAN_SEL1 jumper is for the CPU fan control and the CHAFAN_SEL1 jumper is for the front fans and rear fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.
4. 5. 2-24 LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allow you to enable or disable the onboard Intel® 82574L Gigabit LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature. RAID configuration utility selection (3-pin RAID_SEL1) This jumper allows you to select the RAID configuration utility to use when you create disk arrays.
6. Force BIOS recovery setting (3-pin RECOVERY1) This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted. To update the BIOS: 1. 2. 3. 4. 5. 6. Prepare a USB flash disk that contains the original or latest BIOS for the motherboard (XXXXXX.ROM) and the BUPDATER.EXE utility. Set the jumper to pins 2–3. Insert the USB flash and turn on the system to update the BIOS. Shut down the system. Set the jumper back to pins 1–2. Turn on the system.
7. Chassis intrusion connector (2-pin CHASSIS) This connector is for a chassis-mounted intrusion detection sensor or switch. Connect one end of the chassis intrusion sensor or switch cable to this connector. The chassis intrusion sensor or switch sends a high-level signal to this connector when a chassis component is removed or replaced. The signal is then generated as a chassis intrusion event. By default , the pin labeled “Chassis Signal” and “Ground” are shorted with a jumper cap.
2.7 Connectors 2.7.1 Rear panel connectors 1. 2. 3. 4. 5. 6. 7. 8. PS/2 mouse port (green). This port is for a PS/2 mouse. RJ-45 port for iKVM. This RJ-45 port functions only when you install ASMB5 management card. PS/2 keyboard port (purple). This port is for a PS/2 keyboard. USB 2.0 ports 1 and 2. These two 4-pin Universal Serial Bus (USB) ports are available for connecting USB 2.0 devices. Serial (COM1) port. This 9-pin communication port is for pointing devices or other serial devices.
2.7.2 1. Internal connectors Serial ATA connectors (P8B-M) (SATA 6Gb/s: 7-pin SATA1, SATA2 [Blue]) (SATA 3Gb/s: 7-pin SATA3, SATA4, SATA5, SATA6 [Black]) Serial ATA connectors (P8B-MX) (SATA 3Gb/s: 7-pin SATA1-6 [Black]) These connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allow 6Gb/s and/or 3 Gb/s of data transfer rate. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 10, or RAID 5 configuration.
2. 3. Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card. The read or write activities of any device connected to the SATA or SAS add-on card causes the front panel LED to light up. USB connector (10-1 pin USB34, USB56; A-Type USB7) These connectors are for USB 2.0 ports. Connect the USB module cables to connectors USB34 and USB56, then install the modules to a slot opening at the back of the system chassis.
4. CPU, front and rear fan connectors (4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1) The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.) or a total of 3.15 A–6.66 A (53.28 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire of each cable matches the ground pin of the connector. 2-30 • DO NOT forget to connect the fan cables to the fan connectors.
5. 6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) This connector is used for the SGPIO peripherals for the Intel Rapid Storage Technology RAID SATA LED. Thermal sensor cable connectors (3-pin TR1) This connector is for temperature monitoring. Connect the thermal sensor cable to this connector and place the other end to the device, which you want to monitor temperature. You can connect the thermal sensor cable to either pin 1-2 or pin 2-3.
7. 8. 2-32 Serial port connector (10-1 pin COM2) Thess connectors are for the serial (COM) ports. Connect the serial port module cable to one of these connectors, then install the module to a slot opening at the back of the system chassis. BMC header (BMC_FW1) The BMC connector on the motherboard supports an ASUS® Server Management Board 5 Series (ASMB5).
9. Power Supply SMBus connector (5-pin PSUSMB1) This connector allows you to connect SMBus (System Management Bus) to the power supply unit to read PSU information. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface. This connector functions only when you install the ASUS ASMB5. 10. TPM connector (20-1 pin TPM) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data.
11. 2-34 ATX power connectors (24-pin ATXPWR1, 8-pin ATX12V1) These connectors are for the ATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • DO NOT forget to connect the 24+8-pin power plugs. Otherwise, the system will not boot up. • We recommend that you use a PSU with a higher power output when configuring a system with more power-consuming devices.
12. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1. 2. 3. 4. 5. 6. System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
13. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 2-36 1. Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. 2. LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel. 3.
This chapter describes the power up sequence, and ways of shutting down the system.
Chapter summary 3.1 3.2 3 Starting up for the first time......................................................... 3-3 Powering off the computer...........................................................
3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 2. Ensure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis. 4. Connect the power cord to a power outlet that is equipped with a surge protector. 5. Turn on the devices in the following order: a. Monitor c. System power b. 6.
3.2 Powering off the computer 3.2.1 Using the OS shut down function If you are using Windows® 2008 Server: 1. Click the Start button, move the cursor to the triangle on the right of Log off, and then click Shut Down. 2. From the Shutdown Event Tracker, select the option that best describes why you want to shut down the computer. 3. Tick Planned. 4. If necessary, key in comments. 5. Click OK. 3.2.
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
Chapter summary 4 4.1 Managing and updating your BIOS............................................. 4-3 4.3 Main menu................................................................................... 4-10 4.2 4.4 4.5 4.6 4.7 4.8 4.9 BIOS setup program..................................................................... 4-7 Event Logs menu........................................................................ 4-12 Advanced menu..........................................................................
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. 3. ASUS CrashFree BIOS 3 : Allows you to recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted. ASUS EZ Flash 2 : Allows you to update the BIOS using a USB flash disk. BUPDATER utility : Allows you to update the BIOS in DOS mode using a bootable USB flash disk drive.
4.1.2 ASUS EZ Flash ASUS EZ Flash allows you to update the BIOS without using a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash 1. 2. Insert the USB flash disk that contains the latest BIOS file to the USB port. Enter the BIOS setup program. Go to the Tool menu to select ASUS EZ Flash Utility and press to enable it. Exit ASUSTek EZ Flash BIOS ROM Utility V00.
• This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press and select Yes to load the BIOS default settings. 4.1.3 BUPDATER The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
The utility verifies the file, then starts updating the BIOS file. ASUSTek BIOS Update for DOS V1.06 (09/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: P8B-M series VER: 0201 DATE: 12/01/2010 Update ROM BOARD: P8B-M series VER: 0202 DATE: 12/09/2010 PATH: WARNING! Do not turn off power during flash BIOS Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Main Menu bar Configuration fields General help Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit BIOS Information BIOS Version Build Date 0202 x64 02/14/2011 Set the Date, Use Tab to switch between Data elements. CPU Information Intel(R) Xeon(R) CPU E31230 @ 3.
4.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Event Logs, Advanced, Monitor, Boot, Tool, and Exit) on the menu bar have their respective menu items. 4.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item and press . 4.2.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time, language, and security settings. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit BIOS Information BIOS Version Build Date 0202 x64 02/14/2011 Set the Date, Use Tab to switch between Data elements.
Administrator Password If you have set an administrator password, we recommend that you enter the administrator password for accessing the system. Otherwise, you might be able to see or change only selected fields in the BIOS setup program. To set an administrator password: 1. Select the Administrator Password item and press . 3. Confirm the password when prompted. 2. From the Create New Password box, key in a password, then press . To change an administrator password: 1. 2. 3. 4.
4.4 Event Logs menu The Event Logs menu items allow you to change the event log settings and view the system event logs. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit Change Smbios Event Log Settings View Smbios Event Log View System Event Log Press to change the Smbios Event Log configuration. Change Smbios Event Log Settings Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
Log OEM Codes [Enabled] Allows you to enable or disable the logging of EFI status codes as OEM codes. Configuration option: [Disabled] [Enabled] Convert OEM Codes [Disabled] Allows you to enable or disable the converting of EFI status codes to standard Smbios types. Configuration option: [Disabled] [Enabled] View Smbios Event Log Press to view the Smbios event logs. View System Event Log Press to view the system event logs.
4.5 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Be cautious when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
4.5.2 Trusted Computing Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced TPM Configuration TPM SUPPORT [Disabled] Current TPM Status Information NO TPM Hardware Enables or Disables TPM support. O.S. will not show TPM. Reset of platform is required. TPM SUPPORT [Disabled] Allows you to enable or disable the TPM support. Configuration options: [Disabled] [Enabled] 4.5.3 WHEA Configuration Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
4.5.4 CPU Configuration The items in this menu show the CPU-related information that the BIOS automatically detects. Some items may not appear if your CPU does not support the related functions. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Includes TM1, TM2 and EMTTM CPU Configuration Intel(R) Xeon(R) CPU E31230 @ 3.
Execute Disable Bit [Enabled] Allows you to enable or disable the No-Execution Page Protection Technology. Setting this item to [Disabled] forces the XD feature flag to always return to zero (0). Configuration options: [Disabled] [Enabled] Intel Virtualization Tech [Enabled] The Intel® Virtualization Technology allows a hardware platform to run multiple operating systems separately and simultaneously, enabling one system to virtually function as several systems.
4.5.5 North Bridge The North Bridge is built in the CPU. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Low MMIO resources align at 64MB/1024MB Memory Information TOTAL Memory 1024 MB DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2 Low MMIO Align DMI Gen2 VT-d Initate Graphic Adapter 0 MB (DDR3 0 MB (DDR3 0 MB (DDR3 1024 MB (DDR3 [64M] [Enabled] [Disabled] [PEG/PCI] 1333) 1333) 1333) 1333) Low MMIO Align [64M] Allows you to select the options for the Low MMIO Align.
4.5.7 SATA Configuration While entering Setup, the BIOS automatically detects the presence of SATA devices. The SATA Port items show Not Present if no SATA device is installed to the corresponding SATA port. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced SATA Configuration SATA Mode Serial-ATA Controller 0 Serial-ATA Controller 1 S.M.A.R.T. Status Check [IDE Mode] [Enhanced] [Enhanced] [Enabled] SATA Port1 ST3160812AS (160.0GB) SATA Port2 ST3160812AS (160.
S.M.A.R.T. Status Check [Enabled] S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) is a monitor system. When hard disk read/write errors occur, this feature allows the hard disk to report warning messages during the POST. Configuration options: [Enabled] [Disabled] 4.5.8 Intel TXT(LT) Configuration Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Intel Trusted Execution Technology Configuration Intel TXT support only can be enabled/disabled if SMX is enabled.
EHCI Hand-off [Disabled] Enables or disables the BIOS EHCI hand-off support. Configuration options: [Disabled] [Enabled] USB transfer time-out [20 sec] Allows you to select the USB transfer time-out value. Configuration options: [1 sec] [5 sec] [10 sec] [20 sec] Device reset time-out [20 sec] Allows you to select the USB device reset time-out value.
Change Settings [Auto] Allows you to select the serial port base address. Configuration options: [Auto] [IO=3F8h; IRQ=4] [IO=3F8h: IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12] [IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12] [IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12] [IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12] 4.5.11 APM Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
Power On By RTC [Disabled] [Disabled] [Enabled] 4.5.12 Disables RTC to generate a wake event. When set to [Enabled], the items RTC Alarm Date (Days) and Hour/Minute/Second will become user-configurable with set values. Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
Data Bits [8] Configuration options: [7] [8] Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [Even] parity bit is 0 if the num of 1’s in the data bits is even [Odd] parity bit is 0 if num of 1’s in the data bits is odd [Mark] parity bit is always 1 [Space] parity bit is always 0 Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.
4.6 Monitor menu The Monitor menu displays the system temperature/power status, and allows you to change the fan settings. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit CPU Temperature(PECI) MB Temperature TR1 Temperature CPU FAN1 Speed FRNT FAN1 Speed FRNT FAN2 Speed FRNT FAN3 Speed REAR FAN1 Speed FAN Speed Control VCORE1 +3.3V +5V +12V VBAT +3VSB +1.
4.7 Boot menu The Boot menu items allow you to change the system boot options. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit Setup Prompt Timeout Bootup NumLock State Full Screen Logo Option ROM Messages Interrupt 19 Capture EFI Boot Boot Device Seeking 5 [On] [Enabled] [Force BIOS] [Enabled] [Disabled] [Endless PXE] Boot Option Priorities Boot Option #1 Boot Option #2 [IBA GE Slot 0200 v...
Boot Device Seeking [Endless PXE] [Endless PXE] Continuously searches for the remote boot image until it is found or the process is aborted (press Ctrl+Alt+Del). [Normal] Searches for the remote boot image once, then stops. Boot Option Priorities These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system.
4.8 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit ASUS EZ Flash Utility Be used to update BIOS ASUS EZ Flash Utility Allows you to run ASUS EZ Flash BIOS ROM Utility when you press . Check section 4.1.2 ASUS EZ Flash Utility for details. 4.
This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities.
Chapter summary 5 5.1 Setting up RAID............................................................................. 5-3 5.3 Intel® Rapid Storage Technology Option ROM Utility.............. 5-25 5.2 LSI Software RAID Configuration Utility.....................................
5.1 Setting up RAID The motherboard comes with the Intel® C204 controller that supports the following SATA RAID solutions: • • LSI MegaRAID software RAID Configuration Utility (default) with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Technology with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). 5.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks.
5.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. 2. 3. Install the SATA hard disks into the drive bays following the instructions in the system user guide. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard.
5.2 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility: 1. 2. Turn on the system after installing all the SATA hard disk drives.
Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow keys to select the drives you want to include in the RAID set, and then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5. Press again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
8. 9. Select Units from the Virtual Drive sub-menu, and then press . Select the units for virtual drive size from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
12. When you have finished configuring the selected virtual drive, select Accept from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
Using New Configuration When a RAID set already exists, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option 1. From the Management Menu, select Configure > New Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.3 Initializing the virtual drives After creating the RAID set, you must initialize the virtual drives. You may initialize the virtual drives of a RAID set using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command: 1. From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
3. Press to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.
Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. Select Initialize from the pop-up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive: 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. After selecting the drive to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
5.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command: 1.
3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
Using the Objects command To check data consistency using the Objects command: 1. 2. 3. 4. 5. From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press . Select Check Consistency from the pop-up menu, and then press . When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue.
5.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.7 Selecting the boot drive from a RAID set Create a new RAID configuration before selecting the boot drive from a RAID set. For more details, refer to 5.2.1 Creating a RAID set: Using New Configuration. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache: 1. 2.
5.3 Intel® Rapid Storage Technology Option ROM Utility The Intel® Rapid Storage Technology Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 sets from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. To enter the Intel® Rapid Storage Technology option ROM utility: 1. Install all the Serial ATA hard disk drives. 3. During POST, press to display the utility main menu. 2. Turn on the system.
5.3.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select 1. Create RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Sync: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8.
2. 3. 4. Enter a name for the recovery set and press . When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press . When the Disks item is selected, press to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3160812AS ST3160812AS ST3160812AS ST3160812AS Serial # 9LS0HJA4 9LS0F4HL 3LS0JYL8 9LS0BJ5H Size 149.0GB 149.0GB 149.0GB 149.
5.3.3 Deleting a RAID set Be cautious when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.3.4 Resetting disks to Non-RAID Be cautious before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk.
5.3.5 Recovery Volume Options If you have created a recovery set, you can configure more recovery set options following the descriptions in the section. See section 5.3.2 Creating a Recovery set to create a recovery set before continue. To configure a recovery set: 1. From the utility main menu, select 4. Recovery Volume Options and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
5.3.6 Exiting the Intel® Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 5. Exit, and then press . The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press to exit or press to return to the utility main menu. 5.3.7 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Recovery Volume Options 5.
5.3.8 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Rapid Storage Technology. To set the boot array in the BIOS: To be able to boot from the hard disk, create at least one bootable array. 1. 2. 3. 4. 5. 5-34 Reboot the system and press to enter the BIOS setup utility during POST. Go to the Boot menu and select the boot option priority.
This chapter provides the instructions for installing the necessary drivers for different system components.
Chapter summary 6 6.1 RAID driver installation................................................................ 6-3 6.3 LAN driver installation................................................................ 6-17 6.2 6.4 6.5 Intel chipset device software installation................................. 6-15 VGA driver installation............................................................... 6-20 Management application and utilities installation...................
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk The system does not include a floppy drive. You have to use a USB floppy drive when creating a SATA RAID driver disk.
C20x LSI RAID Driver C20x LSI RAID Driver Windows XP 32 bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL AS4 UP7 32/64 bit RHEL AS4 UP8 32/64 bit RHEL 5 UP4 32/64 bit RHEL 5 UP5 32/64 bit RHEL 6 32 bit RHEL 6 64 bit SLES 10 SP2 32 bit SLES 10 SP2 64 bit SLES 10 SP3 32 bit SLES 10 SP3 64 bit SLES 11 32 bit 6. 7. 8.
To create a RAID driver disk in Windows® environment 1. Start Windows®. 3. Go to the Make disk menu, and then select the type of RAID driver disk you want to create. 2. 4. 5. Place the motherboard support DVD into the optical drive. Insert a floppy disk into the USB floppy disk drive. Follow succeeding screen instructions to complete the process. Write-protect the floppy disk to avoid computer virus infection. To create a RAID driver disk in Red Hat® Enterprise Linux server environment 1. 2.
6.1.2 Installing the RAID controller driver During Windows® Server 2003 / XP OS installation To install the RAID controller driver when installing Windows® Server 2003 / XP OS 1. 2. Boot the computer using the Windows® Server 2003 / XP installation disc. The Windows® Setup starts. Press when the message “Press F6 if you need to install a third party SCSI or RAID driver...” appears at the bottom of the screen. Windows Setup Press F6 if you need to install a third party SCSI or RAID driver... 3.
4. Insert the RAID driver disk you created earlier to the floppy disk drive, then press . Windows Setup Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A: * Press ENTER when ready. ENTER=Continue 5. 6. 7. ESC=Cancel F3=Exit Select the RAID controller driver you need from the list, and then press . The Windows® Setup loads the RAID controller drivers from the RAID driver disk. When the next screen appears, press to continue installation.
During Windows® Server 2008 OS installation To install the RAID controller driver when installing Windows® Server 2008 OS 1. 2. 6-8 Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen instructions to start installing Windows Server 2008. When prompted to choose a type of installation, click Custom (advanced). 3. Click Load Driver. 4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller driver.
5. 6. Locate the driver in the corresponding folder of the Support DVD, and then click OK to continue. Select the RAID controller driver you need from the list and click Next. 7. When the system finishes loading the RAID driver, replace the motherboard Support DVD with the Windows Server installation disc. Select the drive to install Windows and click Next. 8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
Red Hat® Enterprise Linux OS 5.0 To install the RAID controller driver when installing Red Hat® Enterprise OS: 1. Boot the system from the Red Hat® OS installation CD. 3. Press . 2. At the boot:, type linux dd. - To install or upgrade in graphical mode, press the key. - To install or upgrade in text mode, type: linux text . - Use the function keys listed below for more information. [F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue] boot: linux dd 4.
6. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes 7. No Follow the onscreen instructions to finish the OS installation.
SUSE Linux 11 OS To install the RAID controller driver when installing SUSE Linux Enterprise Server OS: 1. 2. Boot the system from the SUSE OS installation CD. Use the arrow keys to select Installation from the Boot Options menu. Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options | F1 Help F2 Language F3 Video Mode English(US) 1024 X768 3.
4. Insert the RAID driver disk to the floppy disk drive. Type the command acpi=off apic=bigsmp brokenmodules=ahci in Boot Options field, and press . Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options acpi=off apic=bigsmp brokenmodules=ahci F1 Help F2 Language F3 Video Mode English(US) 1024 X768 5.
6. The drivers for the RAID controller are installed to the system as shown below. Please choose the Driver Update medium. sda: USB Floppy sr0: CD-ROM, ASUS DRW-1612BLT sdb: Disk, LSI MEGA RAID sd3: Disk, LSI MEGA RAID Console other device OK 7. 6-14 Back Select Back and follow the onscreen instructions to finish the installation.
6.2 Intel® chipset device software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6-16 5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. After completing the installation, click Finish to complete the setup process.
6.3 LAN driver installation This section provides the instructions on how to install the Intel® Gigabit LAN controller drivers on the system. You need to manually install the LAN contrroller driver on a Windows® operating system. To install the LAN controller drivers: 1. 2. 3. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
6-18 4. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation.
7. Follow the screen instructions to complete installation. 8. When finished, press Finish to continue.
6.4 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Enter the user information and click Next to continue. 7. Select a setup type and click Next to continue.
6-22 8. Click Install to start driver installation. 9. When the installation completes, click Finish to restart your computer before using the program.
6.5 Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.5.1 Running the support DVD Place the support DVD to the optical drive.
6.5.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 6.5.4 Make disk menu The Make disk menu contains items to create the Intel RAID and LSI MegaRAID driver disks. 6.5.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.
This appendix includes additional information that you may refer to when configuring the motherboard.
Appendix summary A.1 A.2 A P8B-M block diagram................................................................ 3-A-3 P8B-MX block diagram.............................................................
A.1 P8B-M block diagram * DDR3 1600 can only be supported with Intel® Xeon® E3-1200 v2 Processor. * Gen3 link can only be supported with Intel® Xeon® E3-1200 v2 Processor.
A.2 P8B-MX block diagram * DDR3 1600 can only be supported with Intel® Xeon® E3-1200 v2 Processor. * Gen3 link can only be supported with Intel® Xeon® E3-1200 v2 Processor.
ASUS contact information ASUSTeK COMPUTER INC. (Taiwan) Address Telephone Fax E-mail Web site Technical Support Telephone Online Support 15 Li-Te Road, Peitou, Taipei, Taiwan 11259 +886-2-2894-3447 +886-2-2890-7798 info@asus.com.tw http://www.asus.com.tw +886-2-2894-3447 (0800-093-456) http://support.asus.com/techserv/techserv.aspx ASUSTeK COMPUTER INC. (China) Address Telephone Fax Web site Technical Support Telephone Online Support No.
(510)739-3777/(510)608-4555 800 Corporate Way, Fremont, CA 94539. Asus Computer International Date : Signature : Representative Person’s Name : Mar. 11, 2011 Steve Chang / President This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.