5-10 Chapter 5: RAID Conguration
5.2.6 Rebuilding the RAID
This option is only for the RAID 1, RAID 5 and RAID 10 sets.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID array failed, the sys-
tem displays the status of the RAID volume as “Degraded” during POST. You 
can rebuild the RAID array with other installed non-RAID disks. 
To rebuild the RAID with other non-RAID disk:
1.  At  the  prompt,  press  <Ctrl>  +  <I>  to  enter  the  Intel  Matrix  Storage 
Manager RAID conguration. 
2.  If there is a non-RAID SATA Hard Disk available, the utility will prompt to 
rebuild the RAID. Press <Enter>, then use up/down arrow keys to select  
the destination disk or press <ESC> to exit. 
Select a destination disk with the same size as the original hard disk.
3.  The utilty immediately starts rebuilding after the disk is selected. The 
status of the degraded RAID volume is changed to “Rebuild”. 
DEGRADED VOLUME DETECTED
“Degraded“ volume and disk available for rebuilding detected. 
Selecting a disk initiates a rebuild. Rebuild completes in the 
operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model  Serial#  Size
3HDS722580VLSA80  VN6Bxxxx  76.7GB
[ ]- Previous/Next [Enter]- Selects [ESC]- Exit