E6399 First Edition March 2011 Copyright © 2011 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Notices......................................................................................................... vii Safety information..................................................................................... viii About this guide........................................................................................... x Chapter 1: 1.1 1.2 1.3 Product introduction System package contents............................................................ 1-2 Serial number label.............
Contents 2.8 2.9 2.7.2 System fan................................................................................... 2-18 Cable connections...................................................................... 2-19 Chapter 3: Motherboard Info 3.1 Motherboard layout....................................................................... 3-2 3.3 Internal connectors....................................................................... 3-8 3.2 Jumpers...................................................
Contents 4.5.6 South Bridge.................................................................. 4-17 4.5.8 Intel TXT(LT) Configuration............................................ 4-19 4.5.7 4.5.9 4.5.10 4.5.11 4.6 4.7 4.8 4.9 4.5.12 Onboard Devices Configuration..................................... 4-20 APM............................................................................... 4-22 Serial Port Console Redirection..................................... 4-23 Boot menu..............................
Contents Chapter 6: 6.1 Driver installation RAID driver installation................................................................ 6-2 6.1.1 6.1.2 Creating a RAID driver disk............................................. 6-2 Installing the RAID controller driver................................. 6-5 6.2 Intel® chipset device software installation.................................. 6-8 6.3 6.4 LAN driver installation................................................................
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Safety information Electrical Safety • • • • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing any additional devices to or from the system, contact a qualified service technician or your dealer.
REACH Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we published the chemical substances in our products at ASUS website at http://csr.asus.com/english/REACH.htm. ASUS Recycling/Takeback Services ASUS recycling and takeback programs come from our commitment to the highest standards for protecting our environment.
About this guide Audience This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server. Contents This guide contains the following parts: 1. 2. 3. 4. 5. 6 Chapter 1: Product Introduction This chapter describes the general features of the server, including sections on front panel and rear panel specifications.
Typography Bold text Italics Indicates a menu or an item to select. Used to emphasize a word or a phrase. Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key. Example: means that you must press the Enter or Return key. If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).
xii
This chapter describes the general features of the server, including sections on front panel and rear panel specifications.
1.1 System package contents Check your system package for the following items.
1.3 System specifications The ASUS TS100-E7/PI4 is a pedestal barebone server system featuring the ASUS P8B-X/MR server board. The server supports Intel® LGA1155 Lynnfield / Clarkdale processors, plus other latest technologies through the chipsets onboard.
OS Support Anti-virus Software Management Software Solution Dimension (HH x WW x DD) Net Weight Kg (CPU, DRAM & HDD not inclu ded) Power Supply Power Rating Environment Windows® Server 2008 R2 Windows® Server 2008 Enterprise 32/64-bit Windows® Server 2003 R2 Enterprise 32/64-bit RedHat® Enterprise Linux AS5.5/6.0 32/64-bit SuSE® Linux Enterprise Server 10 SP3/11 32/64-bit (Subject to change without any notice) Optional Anti-Virus CD Pack ASUS ASWM Enterprise 436.8mm * 200mm * 478.
1.4 Front panel features The barebone server displays a simple yet stylish front panel with easily accessible features. The power and reset buttons, LED indicators, optical drive, and two USB ports are located on the front panel. The drive bays, power and reset buttons, LED indicators, CD/DVD-ROM drive, and USB 2.0 ports are located on the front panel. For future installation of 5.25-inch devices, two drive bays are available. Optical drive Empty 5.
1.5 Rear panel features The rear panel includes a slot for the motherboard rear I/O ports, expansion slots, a chassis lock, a vent for the system fan, and power supply module. Power connector 300W Single power supply PS/2 mouse port PS/2 keyboard port USB 2.
1.6 Internal features The barebone server includes the basic components as shown. 5 1 6 7 2 3 8 4 1. Power supply unit 3. ASUS P8B-X/MR Server Board 2. 4. 5. 6. 7. 8. 120mm x 25mm system fan Expansion card locks Optical drive 2 x 5.25-inch drive bays Front I/O board (hidden) Internal HDD bays Turn off the system power and detach the power supply before removing or replacing any system component. The barebone server does not include a floppy disk drive and an optical disc drive.
1.7 LED information 1.7.1 Front panel LEDs HDD Access LED Power LED LED Icon Display status Power LED ON HDD Access LED OFF Blinking 1.7.
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
2.1 Chassis cover 2.1.1 Removing the side cover • Ensure that you unplug the power cord before removing the side cover. • Take extra care when removing the side cover. Keep your fingers from components inside the chassis that can cause injury, such as the CPU fan, rear fan, and other sharp-edged parts. • The images of the barebone server shown in this section are for reference purposes only and may not exactly match the model you purchase. To remove the side cover: 1.
2.1.2 Reinstalling the side cover To reinstall the side cover: 1. 2. Match and insert the lower sliding edge of the side cover to the corresponding chassis edge. Position the side cover to the chassis. 1 3. 4. Slide the side cover toward the front panel until it snaps in place. Drive in the two screws you removed earlier to secure the side cover.
2.2 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA1155 socket designed for the Intel® Xeon E3-1200/Core™ i3-2100 processor. 2.2.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related.
3. Lift the load lever in the direction of the arrow until the load plate is completely lifted. Load plate 4. Remove the PnP cap from the CPU socket by lifting the tab only. PnP cap Cap tab 5. Position the CPU over the socket, ensuring that the gold triangle is on the bottom‑left corner of the socket, and then fit the socket alignment keys into the CPU notches. The CPU fits in only one correct orientation.
6. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer. Some heatsinks come with preapplied thermal paste. If so, skip this step. The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off immediately, and seek professional medical help. 7.
2.2.2 Installing the CPU heatsink and fan The Intel LGA1155 processor requires a specially designed heatsink and fan assembly to ensure optimum thermal condition and performance. ® • When you buy a boxed Intel® processor, the package includes the CPU fan and heatsink assembly. If you buy a CPU separately, ensure that you use only Intel®‑certified multi‑directional heatsink and fan. • Your Intel® LGA1155 heatsink and fan assembly comes in a push-pin design and requires no tool to install.
3. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector. 2.2.3 Uninstalling the CPU heatsink and fan To uninstall the CPU heatsink and fan: 1. 2. 3. 4. 2-8 A Disconnect the CPU fan cable from the connector on the motherboard. Rotate each fastener counterclockwise.
2.3 System memory 2.3.1 Overview The motherboard comes with four Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets. A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched differently to prevent installation on a DDR2 DIMM socket. DDR3 modules are developed for better performance with less power consumption. The figure illustrates the location of the DDR3 DIMM sockets: 2.3.
2.3.3 Installing a DIMM Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. 2. 2 Unlock a DIMM socket by pressing the retaining clips outward. DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket. 1 1 Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction.
2.4 Front panel cover Before you can install a 5.25-inch drive, you should first remove the front panel cover. 2.4.1 Removing the front panel cover To remove the front panel cover: 1. 2. Locate the three hooked tabs on the chassis side rail. Release the hooked tabs and take off the front panel cover. 2.4.2 Reinstalling the front panel cover To reinstall the front panel cover: 1. 2. Hook the other side of the front panel cover to the chassis.
2.5 5.25-inch drives Ensure to unplug the power cable before installing or removing any system components. Failure to do so may cause damage to the motherboard and other system components! The system comes with three 5.25-inch drive bays located on the upper front part of the chassis. An optical drive that comes standard/optional with the system package occupies the uppermost bay (labeled 1). The lower bays (labeled 2 and 3) are available for additional 5.25inch optical, or zip disk drives.
4. Insert the drive into the bay. 5. Slide the bay lock to the right until it clicks in place. 6. Connect the SATA cable to the SATA connector on the back of the drive. 7. 8. Connect a power plug from the power supply to the power connector on the back of the drive. 7 6 Follow the instructions on the previous section to reinstall the front panel cover.
2.6 Hard disk drives The server system supports four Serial ATA hard disk drives through screw-free hard disk drive holders. To install a Serial ATA hard disk drive: 1. Secure the supplied HDD trays to the HDD with four screws. 2. Carefully insert the trays with the HDD installed and push them all the way to the depth of the bay. 3. Connect the SATA cable to the SATA connector on the back of the drive. 4.
2.7 Expansion cards The system is designed with an expansion card lock on the rear panel for you to install or remove an expansion card in less steps. Ensure to unplug the power cord before installing or removing expansion cards. Failure to do so may cause severe damage to the motherboard and other system components! 2.7.1 Installing an expansion card To install an expansion card: 1.
6. Align the card golden fingers with the slot, and then press firmly until the card is completely seated on the slot. 7. Restore the expansion card lock to its original position. A light click indicates that the card is locked in place. Ensure that the total power consumption of your system does not exceed 300W.
2.7.2 Configuring an expansion card After installing the expansion card, configure the it by adjusting the software settings. 1. 2. 3. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for information on BIOS setup. Assign an IRQ to the card. Refer to the following tables. Install the software drivers for the expansion card.
2.8 System fan You may need to remove previously installed system fan when it got defective. This section tells how to remove the system fan. To remove the system fan: 1. Unplug the system fan cable from the REAR_FAN1 connector on the motherboard. 2. Locate and remove four system fan screws at the rear panel. Keep the screws for late use. Hold the system fan with one hand while removing the system fan screws. 3. Remove the system fan, and then set it aside.
2.9 Cable connections • The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you will remove pre‑installed components to install additional devices. • Refer to Chapter 3 for detailed information on the connectors. 2 1 3 4 5 6 Standard cables connected to the motherboard 1. 24-pin ATX power connector (from power supply to motherboard) 3. System fan connector (from system fan to motherboard) 2. 4. 5. 6.
2-20 Chapter 2: Hardware setup
This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors.
3.
Layout contents Jumpers Page 1. Clear RTC RAM (CLRTC1) 2. VGA controller setting (3-pin VGA_SW1) 3. CPU Fan and Chassis Fan control setting (3-pin CPUFAN_SEL1, CHAFAN_SEL1) 4. LAN controller setting (3-pin LAN_SW1, LAN_SW2) 5. Intel C202 SATA port S/W RAID setting (3-pin RAID_SEL1) 6. Force BIOS recovery setting (3-pin RECOVERY1) ® Internal connectors 1. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4, SATA5, SATA6) 2. Hard disk activity LED connector (4-pin HDLED1) 3.
3.2 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. 2. 3. 4. Turn OFF the computer and unplug the power cord. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. 3. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. CPU Fan and Chassis Fan control setting (3-pin CPUFAN_SEL1, CHAFAN_SEL1) These jumpers allow you to switch for fan pin selection. The CPUFAN_SEL1 jumper is for the CPU fan control and the CHAFAN_SEL1 jumper is for the front fans and rear fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.
4. 5. 3-6 LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allow you to enable or disable the onboard Intel® 82574L Gigabit LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature. Intel® C202 SATA port S/W RAID setting (3-pin RAID_SEL1) This jumper allows you to select the Serial ATA RAID configuration utility to use when you create disk arrays.
6. Force BIOS recovery setting (3-pin RECOVERY1) This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted. To update the BIOS: 1. 2. 3. 4. 5. 6. Prepare a USB flash disk that contains the original or latest BIOS for the motherboard (XXXXXX.ROM) and the BUPDATER.EXE utility. Set the jumper to pins 2–3. Insert the USB flash and turn on the system to update the BIOS. Shut down the system. Set the jumper back to pins 1–2. Turn on the system.
3.3 1. Internal connectors Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4, SATA5, SATA6) Supported by the Intel® C202 chipset, these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 3Gb/s of data transfer rate. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 10, or RAID 5 configuration. The actual data transfer rate depends on the speed of Serial ATA hard disks installed.
2. Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card. The read or write activities of any device connected to the SATA or SAS add-on card causes the front panel LED to light up.
3. 4. 3-10 USB connector (10-1 pin USB34, USB56; A-Type USB7) These connectors are for USB 2.0 ports. Connect the USB module cables to connectors USB34 and USB56, then install the modules to a slot opening at the back of the system chassis. These USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. Thermal sensor cable connectors (3-pin TR1) This connector is for temperature monitoring.
5. CPU, front and rear fan connectors (4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1) The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.) or a total of 3.15 A–6.66 A (53.28 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire of each cable matches the ground pin of the connector. • DO NOT forget to connect the fan cables to the fan connectors.
6. 7. 3-12 Serial General Purpose Input/Output connector (6-1 pin SGPIO1) This connector is used for the SGPIO peripherals for the Intel Rapid Storage Technology RAID SATA LED. Serial port connectors (10-1 pin COM2) This connector is for the serial (COM) port. Connect the serial port module cable to one of these connectors, then install the module to a slot opening at the back of the system chassis.
8. TPM connector (20-1 pin TPM) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data. A TPM system also helps enhance network security, protects digital identities, and ensures platform integrity.
9. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1) These connectors are for an ATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. 3-14 • DO NOT forget to connect the 24+8-pin power plugs; otherwise, the system will not boot up. • Use of a PSU with a higher power output is recommended when configuring a system with more power-consuming devices.
10. System panel connector (20-pin PANEL1) This connector supports several chassis-mounted functions. 1. 2. 3. 4. 5. 6. System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
11. 3-16 Auxiliary panel connector (20-pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 1. Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. 2. LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel. 3.
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. 3. ASUS CrashFree BIOS 3 (To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted.) ASUS EZ Flash 2 (Updates the BIOS using a USB flash disk.) BUPDATER utility (Updates the BIOS in DOS mode using a bootable USB flash disk drive.) Refer to the corresponding sections for details on these utilities.
4.1.2 ASUS EZ Flash Utility The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash Utility 1. 2. Insert the USB flash disk that contains the latest BIOS file to the USB port. Enter the BIOS setup program. Go to the Tool menu to select ASUS EZ Flash Utility and press to enable it.
• This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press and select Yes to load the BIOS default settings. 4.1.3 BUPDATER utility The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
4. The utility verifies the file, then starts updating the BIOS file. ASUSTek BIOS Update for DOS V1.06 (09/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: P8B-X VER: 0201 DATE: 12/01/2010 Update ROM BOARD: P8B-X VER: 0202 DATE: 12/09/2010 PATH: WARNING! Do not turn off power during flash BIOS Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the DOS prompt after the BIOS update process is completed.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Main Menu bar Configuration fields General help Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit BIOS Information BIOS Version Build Date 0602 x64 02/17/2011 Set the Date, Use Tab to switch between Data elements. CPU Information Intel(R) Xeon(R) CPU E31230 @ 3.
4.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Event Logs, Advanced, Monitor, Boot, Tool, and Exit) on the menu bar have their respective menu items. 4.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item and press . 4.2.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time, language, and security settings. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit BIOS Information BIOS Version Build Date 0602 x64 02/17/2011 Set the Date, Use Tab to switch between Data elements.
Administrator Password If you have set an administrator password, we recommend that you enter the administrator password for accessing the system. Otherwise, you might be able to see or change only selected fields in the BIOS setup program. To set an administrator password: 1. Select the Administrator Password item and press . 3. Confirm the password when prompted. 2. From the Create New Password box, key in a password, then press . To change an administrator password: 1. 2. 3. 4.
4.4 Event Logs menu The Event Logs menu items allow you to change the event log settings and view the system event logs. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit Change Smbios Event Log Settings View Smbios Event Log Press to change the Smbios Event Log configuration. Change Smbios Event Log Settings Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
Log OEM Codes [Enabled] Allows you to enable or disable the logging of EFI status codes as OEM codes. Configuration option: [Disabled] [Enabled] Convert OEM Codes [Disabled] Allows you to enable or disable the converting of EFI status codes to standard Smbios types. Configuration option: [Disabled] [Enabled] View Smbios Event Log Press to view the Smbios event logs.
4.5 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
4.5.2 Trusted Computing Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced TPM Configuration TPM SUPPORT [Disabled] Current TPM Status Information NO TPM Hardware Enables or Disables TPM support. O.S. will not show TPM. Reset of platform is required. TPM SUPPORT [Disabled] Allows you to enable or disable the TPM support. Configuration options: [Disabled] [Enabled] 4.5.3 WHEA Configuration Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
4.5.4 CPU Configuration The items in this menu show the CPU-related information that the BIOS automatically detects. Some items may not appear if your CPU does not support the related functions. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Includes TM1, TM2 and EMTTM CPU Configuration Intel(R) Xeon(R) CPU E31230 @ 3.
Execute Disable Bit [Enabled] Allows you to enable or disable the No-Execution Page Protection Technology. Setting this item to [Disabled] forces the XD feature flag to always return to zero (0). Configuration options: [Disabled] [Enabled] Intel Virtualization Tech [Enabled] The Intel® Virtualization Technology allows a hardware platform to run multiple operating systems separately and simultaneously, enabling one system to virtually function as several systems.
4.5.5 North Bridge The North Bridge is built in the CPU. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Low MMIO resources align at 64MB/1024MB Memory Information TOTAL Memory 1024 MB DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2 Low MMIO Align DMI Gen2 VT-d Initate Graphic Adapter 0 MB (DDR3 1024 MB (DDR3 0 MB (DDR3 0 MB (DDR3 [64M] [Enabled] [Disabled] [PEG/PCI] 1333) 1333) 1333) 1333) Low MMIO Align [64M] Allows you to select the options for the Low MMIO Align.
4.5.7 SATA Configuration While entering Setup, the BIOS automatically detects the presence of SATA devices. The SATA Port items show Not Present if no SATA device is installed to the corresponding SATA port. Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced SATA Configuration SATA Mode Serial-ATA Controller 0 Serial-ATA Controller 1 S.M.A.R.T. Status Check [IDE Mode] [Enhanced] [Enhanced] [Enabled] SATA Port1 ST3160812AS (160.0GB) SATA Port2 ST3160812AS (160.
4.5.8 Intel TXT(LT) Configuration Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Intel Trusted Execution Technology Configuration Intel TXT support only can be enabled/disabled if SMX is enabled. VT and VT-d support must also be enabled prior to TXT. Secure Mode Extensions (SMX) Enabled Intel TXT(LT) Support [Disabled] Enables Legacy USB support. AUTO option disables legacy support if no USB devices are connected.
USB transfer time-out [20 sec] Allows you to select the USB transfer time-out value. Configuration options: [1 sec] [5 sec] [10 sec] [20 sec] Device reset time-out [20 sec] Allows you to select the USB device reset time-out value. Configuration options: [10 sec] [20 sec] [30 sec] [40 sec] Device power-up delay [Auto] Configuration options: [Auto] [Manual] Device power-up delay in seconds [XX] This item appears only when you set the Device power-up delay item to [Manual].
Serial Port [Enabled] Allows you to enable or disable the serial port (COM). Configuration options: [Enabled] [Disabled] Change Settings [Auto] Allows you to select the serial port base address.
4.5.11 APM Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Restrore AC EuP Ready Power On By Power On By Power On By Power On By Power Loss PCI PCIE Ring RTC [Power Off] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] Specify what state to go to when power is re-applied after a power failure (G3 state). Restore AC Power Loss [Power Off] When set to [Power Off], the system goes into off state after an AC power loss.
4.5.12 Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Advanced Redirection After BIOS POST [Disabled] COM1 Console Redirection Console Redirection Settings [Enabled] COM2 Console Redirection Console Redirection Settings [Disabled] Redirection After BIOS POST [Disabled] Enables or disables the redirection after BIOS POST feature.
Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.) The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. Configuration options: [1] [2] Flow Control [Hardware RTS/CTS] Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a stop signal can be sent to stop the data flow. Once the buffers are empty, a start signal can be sent to re-start the flow.
4.6 Monitor menu The Monitor menu displays the system temperature/power status, and allows you to change the fan settings. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit CPU Temperature(PECI) MB Temperature TR1 Temperature CPU FAN1 Speed FRNT FAN1 Speed FRNT FAN2 Speed FRNT FAN3 Speed REAR FAN1 Speed FAN Speed Control VCORE1 +3.3V +5V +12V VBAT +3VSB +1.
4.7 Boot menu The Boot menu items allow you to change the system boot options. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit Setup Prompt Timeout Bootup NumLock State Full Screen Logo Option ROM Messages Interrupt 19 Capture EFI Boot Boot Device Seeking 3 [On] [Disabled] [Force BIOS] [Enabled] [Disabled] [Endless PXE] Boot Boot Boot Boot ...] [IBA GE Slot 0200 v...] [SATA:ASUS DRW-...
Boot Device Seeking [Endless PXE] [Endless PXE] Continuous seek remote boot image until boot image found or user abort (press Ctrl+Alt+Del). [Normal] Seek remote boot image once then stop. Boot Option Priorities These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. • To select the boot device during system startup, press when ASUS Logo appears.
4.8 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. Main Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Event Logs Advanced Monitor Boot Tool Exit ASUS EZ Flash Utility Be used to update BIOS ASUS EZ Flash Utility Allows you to run ASUS EZ Flash 2. When you press . Check section 4.1.2 ASUS EZ Flash 2 utility for details. 4.
This chapter provides instructions for setting up, creating and configuring RAID sets using the available utilities.
5.1 Setting up RAID The motherboard comes with the Intel® C202 southbridge controller that supports the following SATA RAID solutions: • • LSI MegaRAID software RAID Configuration Utility (default) with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Manager with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). 5.1.
5.1.2 Installing hard disk drives The motherboard supports SATA hard disk drives for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. See section 2.6 Hard disk drives for SATA hard disk drive installation. 5.1.3 Setting the RAID item in BIOS You must enable the RAID function in the BIOS Setup before creating RAID set(s) using SATA HDDs. To do this: 1. Enter the BIOS Setup during POST. 3.
5.2 SI Software RAID Configuration L Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility 1. 2. Turn on the system after installing all the SATA hard disk drives.
Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow key to select the drives you want to include in the RAID set, and then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
5. Press again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Virtual VersionDrive(s) A.09.
8. 9. When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual Drive menu, and then press . When creating a RAID 0 set, proceed to step 10. Select On to enable the Disk Write Cache setting, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOSVirtual VersionDrive(s) A.09.
11. Follow step 2 to 10 to configure additional virtual drives. 12. Press to finish RAID configuration. When prompted to save configuration, select Yes from the menu, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
2. Follow step 2 to 7 of the previous section: Using Easy Configuration. 4. Key-in the desired virtual drive size, and then press . 3. Select Size from the Virtual Drive menu, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Virtual VersionDrive(s) A.09.
5.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
5.2.3 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command 1. From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
3. Press to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.07211059R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. Select Initialize from the pop-up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.07211059R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.07211059R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. After selecting the drive to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.07211059R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
5.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command 1.
3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
Using the Objects command To check data consistency using the Objects command 1. 2. 3. 4. 5. 5-20 From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press . Select Check Consistency from the pop-up menu, and then press . When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue.
5.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
5.2.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section 5.2.1 Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press . LSI Software RAID Configuration Utility Ver A.62 Apr 29, 2009 BIOS Version A.09.
5.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache 1. 2. From the Management Menu, select Objects > Adapter, and then press to display the adapter properties.
5.3 Intel® Rapid Storage Technology Option ROM Utilitys The Intel® Rapid Storage Technology Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. To enter the Intel® Rapid Storage Technology option ROM utility: 1. Install all the Serial ATA hard disk drives. 3. During POST, press to display the utility main menu. 2. Turn on the system.
5.3.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select 1. Create RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Sync: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8.
2. 3. 4. Enter a name for the recovery set and press . When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press . When the Disks item is selected, press to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3160812AS ST3160812AS ST3160812AS ST3160812AS Serial # 9LS0HJA4 9LS0F4HL 3LS0JYL8 9LS0BJ5H Size 149.0GB 149.0GB 149.0GB 149.
5.3.3 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.3.4 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk.
5.3.5 Recovery Volume Options If you have created a recovery set, you can configure more recovery set options following the descriptions in the section. See section 5.3.2 Creating a Recovery set to create a recovery set before continue. To configure a recovery set: 1. From the utility main menu, select 4. Recovery Volume Options and press . The following screen appears. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
5.3.6 Exiting the Intel® Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 5. Exit, and then press . The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press to exit or press to return to the utility main menu. 5.3.7 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Recovery Volume Options 5.
5.3.8 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Rapid Storage Technology. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. 2. 3. 4. 5. Reboot the system and press to enter the BIOS setup utility during POST. Go to the Boot menu and select the boot option priority.
5-34 Chapter 5: RAID configuration
This chapter provides instructions for installing the necessary drivers for different system components.
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk The system does not include a floppy drive. You have to use a USB floppy drive when creating a SATA RAID driver disk.
5. Use the arrow keys to select the type of RAID driver disk you want to create and press to enter the sub-menu.
To create a RAID driver disk in Windows® environment 1. Start Windows®. 3. Go to the Make Disk menu, and then select the type of RAID driver disk you want to create. 2. 4. 5. Place the motherboard support DVD into the optical drive. Insert a floppy disk into the floppy disk drive. Follow succeeding screen instructions to complete the process. Write-protect the floppy disk to avoid computer virus infection. To create a RAID driver disk in Red Hat® Enterprise Linux server environment 1. 2.
6.1.2 Installing the RAID controller driver Windows® Server OS During Windows® Server OS installation To install the RAID controller driver when installing Windows® Server OS: 1. Boot the computer using the Windows® Server installation DVD. The Windows® Server OS Setup starts. Windows Setup Press F6 if you need to install a third party SCSI or RAID driver... 2. 3. Press when the message “Press F6 if you need to install a third party SCSI or RAID driver...” appears at the bottom of the screen.
4. Insert the RAID driver disk you created earlier to the USB floppy disk drive, then press . Windows Setup Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A: * ENTER=Continue 5. 6. 7. ESC=Cancel Press ENTER when ready. F3=Exit Select the RAID controller driver you need from the list, then press . The Windows® Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press to continue installation.
To verify the RAID controller driver installation: 1. 2. 3. Right-click the My Computer icon on the Windows® desktop, and then select Properties from the menu. Click the Hardware tab, and then click the Device Manager button. Click the “+” sign before the item SCSI and RAID controllers, and then the Intel(R) ICH8R/ICH9R/ICH10R/DO/PCH SATA RAID Controller item should appear. The screen differs based on the controller. 4. 5. 6.
6.2 Intel® chipset device software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. After completing the installation, click Finish to complete the setup process.
6.3 LAN driver installation This section provides the instructions on how to install the Intel® Gigabit LAN controller drivers on the system. You need to manually install the LAN controller driver on a Windows® operating system. To install the LAN controller drivers: 1. 2. 3. 6-10 Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
4. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation.
6-12 7. Follow the screen instructions to complete installation. 8. When finished, press Finish to continue.
6.4 VGA driver installation This section provides the instructions on how to install the XGI Volari Z9s Video Graphics Adapter (VGA) driver. You need to manually install the XGI Volari Z9s VGA driver on a Windows® operating system. To install theXGI Volari Z9s VGA driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
5. Click Next to start the installation. 6. The system will update the VGA driver. 7. 6-14 When the installation completes, click Finish to restart your computer before using the program.
6.5 Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.5.1 Running the support DVD Place the support DVD to the optical drive.
6.5.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 6.5.4 Make disk menu The Make disk menu contains items to create the Intel and LSI MegaRAID driver disks. 6.5.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.