User’s Manual
Table Of Contents
- About this guide
- Chapter 1: Getting Started
- Chapter 2: Main Menu Overview
- Chapter 3: Deploy Management
- 3.1 Agent Management overview
- 3.2 Deploying agents
- 3.2.1 Automatically scanning and deploying to devices
- 3.2.2 Scanning an IP range
- 3.2.3 Adding and deploying to devices
- 3.2.4 Editing device information
- 3.2.5 Installing agents manually
- 3.2.6 Installing Agents in silent mode
- 3.2.7 Upgrading or repairing agents
- 3.2.8 Setting up a Windows 7 deployment environment
- 3.3 Removing agents
- 3.4 Client Agent Updater
- Chapter 4: Device Information
- Chapter 5: Management Functions
- 5.1 Metadata Management
- 5.2 Software Management
- 5.3 Task Scheduler
- 5.4 OOB Control
- 5.5 Management Control Overview
- 5.6 Management Control Information Overview
- 5.7 DASH Management Control Information
- 5.8 RTL8117 Management Control Information
- 5.9 vPro Management Control Information
- 5.10 BMC Management Control Information
- 5.10.1 Hardware Sensor
- 5.10.2 Inventory
- 5.10.3 Control
- 5.10.4 Remote Desktop
- 5.10.5 Smart BIOS
- 5.10.6 Firmware Update
- 5.10.7 Event Log
- 5.10.8 IPMI
- 5.10.9 IPMI Serial-over-LAN (SOL)
- 5.10.10 Settings
- 5.10.11 Configuration
- 5.10.12 FRU Information
- 5.10.13 Image Redirection
- 5.10.14 Platform Event Filters
- 5.10.15 BSOD Capture
- 5.10.16 Error Codes
- 5.11 Screen Broadcast
- Chapter 6: Settings Migrator
- Chapter 7: Report Generator
- Chapter 8: Account & General Settings
5-154 Chapter 5: Management Functions
Fan Mode
This item allows you to view the current fan mode and switch between different
fan modes.
Availability of certain fan modes depends on client device BMC support.
Generic Mode Set the fan of the client device to generic mode.
Full Speed Mode Set the fan of the client device to full speed mode.
Silent Mode Set the fan of the client device to silent mode.
Turbo Mode Set the fan of the client device to turbo mode.
Fan Customized
This item allows you to specify a custom fan curve.
Availability of this function depends on client device BMC support.
Fan Temperature Source
This item allows you to select a temperature sensor to control fan speed.
• If temperature information is unavailable, the CPU temperature will be
used. If the CPU temperature is also unavailable, the fan speed will default
to 60%.
• To use CHA_FAN sensor and control functions, please ensure that the
fans are connected to the corresponding fan headers and that the 6-pin
PSU connector is connected to a power supply.
• Fan speed control support depends on BMC, motherboard, BIOS, and
firmware support.
SOL Configuration
This item allows you to edit SOL configuration options.
Availability of this function depends on client device BMC support.
Volatile Bit Rate Set the volatile bit rate.
Non-volatile Bit Rate Set the non-volatile bit rate.