User Manual

64
ROG MAXIMUS XII FORMULA BIOS Manual
WATER PUMP+ Control
[Disabled] Disable the WATER PUMP+ control feature.
[Auto] Detects the type of WATER PUMP+ installed and automatically
switches the control modes.
[DC mode] Enable the WATER PUMP+ control in DC mode for 3-pin
chassis fan.
[PWM mode] Enable the water WATER PUMP+ control in PWM mode for
4-pin chassis fan.
The following items appear only when WATER PUMP+ Control is set to [Auto], [DC
mode], or [PWM mode].
WATER PUMP+ Fan Q-Fan Source
The assigned fan will be controlled according to the selected temperature
source.
Configuration options: [CPU] [MotherBoard] [VRM] [Chipset] [T_Sensor]
[Water In T Sensor] [Water Out T Sensor] [Multiple Sources]
For Multiple Sources, select up to three temperature sources and the fan will automatically
change based on the highest temperature.
WATER PUMP+ Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the WATER PUMP+
temperature.
WATER PUMP+ Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum WATER PUMP+ duty
cycle. When the CPU temperature reaches the upper limit, the WATER
PUMP+ will operate at the maximum duty cycle.
WATER PUMP+ Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the WATER PUMP+
temperature.
WATER PUMP+ Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum WATER PUMP+ duty
cycle. When the CPU temperature reaches the upper limit, the WATER
PUMP+ will operate at the maximum duty cycle.
WATER PUMP+ Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the WATER PUMP+
temperature. The WATER PUMP+ will operate at the minimum duty cycle
when the temperature is lower than the limit.
WATER PUMP+ Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum WATER PUMP+ duty
cycle. When the CPU temperature is under the limit, the WATER PUMP+
will operate at the minimum duty cycle.