User Manual
Table Of Contents
- 1. Knowing BIOS
- 2. BIOS setup program
- 3. My Favorites
- 4. Main menu
- 5. Extreme Tweaker menu
- 6. Advanced menu
- 6.1 Platform Misc Configuration
- 6.2 CPU Configuration
- 6.3 System Agent (SA) Configuration
- 6.4 PCH Configuration
- 6.5 PCH Storage Configuration
- 6.6 PCH-FW Configuration
- 6.7 Thermal Configuration
- 6.8 Thunderbolt(TM) Configuration
- 6.9 Trusted Computing
- 6.10 UEFI Variables Protection
- 6.11 PCI Subsystem Settings
- 6.12 USB Configuration
- 6.13 Network Stack Configuration
- 6.14 NVMe Configuration
- 6.15 HDD/SSD SMART Information
- 6.16 APM Configuration
- 6.17 Onboard Devices Configuration
- 6.18 Intel(R) Rapid Storage Technology
- 7. Monitor menu
- 8. Boot menu
- 9. Tool menu
- 10. Exit menu
- 11. Updating BIOS
50
ROG Z790 Series (Intel
®
14
th
) BIOS Manual
TVB Voltage Optimizations
This service controls thermal based voltage optimizations for processors that
implement the Intel Thermal Velocity Boost (TVB) feature. This item is set to
[Enabled] by default. Uses Overclocking Mailbox command 0x18/0x19.
Configuration options: [Auto] [Disabled] [Enabled]
Enhanced TVB
This item is only supported on selected SKUs.
Configuration options: [Auto] [Disabled] [Enabled]
Overclocking TVB
Enable this to be able to draw temperature/frequency dependencies.
Configuration options: [Auto] [Disabled] [Enabled] [+1Boost Profile] [+2Boost Profile]
[Boost Until Target]
+1Boost Profile(K CPU):
This setting will enable additional boost of one bin with the help of Auto Optimized
Temperature Control.
+2Boost Profile(K CPU):
This setting will enable additional boost of two bins with the help of Auto Optimized
Temperature Control.
The following items appear only when Overclocking TVB is set to [Enabled].
1~8-Core Active
Configuration options: [Auto] [Enabled]
The following items appear only when 1~8-Core Active is set to [Enabled].
Temperature A
Package passing this temperature threshold will engage the negative ratio offset
specified in Negative Ratio Offset A. Unit in Degree Celsius.
Configuration options: [Auto] [1] - [115]
Negative Ratio Offset A
This will be the potential negative offset to respective ratio when package temperature
rises above threshold specified in
Temperature A.
Configuration options: [Auto] [User Specify]
The following item appears only when Negative Ratio Offset A is set to [User Specify].
Ratio Offset
Use the <+> and <-> keys to adjust the value.
Configuration options: [0] - [31]
Temperature B
Package passing this temperature threshold will engage the negative ratio offset
specified in
Negative Ratio Offset B. Unit in Degree Celsius.
Configuration options: [Auto] [1] - [115]