User Manual
Table Of Contents
- 1. Knowing BIOS
- 2. BIOS setup program
- 3. My Favorites
- 4. Main menu
- 5. Extreme Tweaker menu
- 6. Advanced menu
- 6.1 Platform Misc Configuration
- 6.2 CPU Configuration
- 6.3 System Agent (SA) Configuration
- 6.4 PCH Configuration
- 6.5 PCH Storage Configuration
- 6.6 PCH-FW Configuration
- 6.7 Thunderbolt(TM) Configuration
- 6.8 Trusted Computing
- 6.9 UEFI Variables Protection
- 6.10 PCI Subsystem Settings
- 6.11 USB Configuration
- 6.12 Network Stack Configuration
- 6.13 NVMe Configuration
- 6.14 HDD/SSD SMART Information
- 6.15 APM Configuration
- 6.16 Onboard Devices Configuration
- 6.17 Intel(R) Rapid Storage Technology
- 7. Monitor menu
- 8. Boot menu
- 9. Tool menu
- 10. Exit menu
- 11. Updating BIOS
ROG Z790 Series BIOS Manual
85
Water Pump+ Point4 Duty Cycle (%)
When the temperature source is lower than the temperature of P4, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P4, the fan will operate at the
duty cycle of P4. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point3 Temperature
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the fan will operate at the
duty cycle of P3-P4. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point3 Duty Cycle (%)
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the fan will operate at the
duty cycle of P3-P4. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point2 Temperature
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the fan will operate at the
duty cycle of P2-P3. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point2 Duty Cycle (%)
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the fan will operate at the
duty cycle of P2-P3. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point1 Temperature
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point1 Duty Cycle (%)
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
AIO Pump Q-Fan Control
Allows you to set the AIO Pump operating mode.
[Auto Detect] Detects the type of installed fan/pump and automatically switches
the control modes.
[DC Mode] Enables the Q-Fan Control feature in DC mode for 3-pin fan/pump.
[PWM Mode] Enables the Q-Fan Control feature in PWM mode for 4-pin fan/
pump.