ROG STRIX B760 Series BIOS Manual
• The following items appear only when you set Chassis Fan 1(~2) Prole to [Manual].
• Use the <+> and <-> keys to adjust the value or directly key in a desired value within
the valid range for each of the items below.
CHASSIS Fan 1(~2) Point4 Temperature
Allows you to set the CHASSIS Fan 1(~2) Point4 Temperature. Conguration
options: [65] – [100]
CHASSIS Fan 1(~2) Point4 Duty Cycle (%)
Allows you to set the CHASSIS Fan 1(~2) Point4 Duty Cycle. Conguration
options: [70] – [100]
When the source temperature is lower than the temperature of P4, the duty cycle will
be dertermined according to the P3-P4 and the source temperature. When the source
temperature is higher than the temperature of P4, the fan will operate at the duty cycle of P4.
CHASSIS Fan 1(~2) Point3 Temperature
Allows you to set the CHASSIS Fan 1(~2) Point3 Temperature. Conguration
options: [70] – [100]
CHASSIS Fan 1(~2) Point3 Duty Cycle (%)
Allows you to set the CHASSIS Fan 1(~2) Point3 Duty Cycle. Conguration
options: [45] – [100]
When the source temperature is lower than the temperature of P3, the duty cycle will
be dertermined according to the P2-P3 and the source temperature. When the source
temperature is higher than the temperature of P3, the duty cycle will be dertermined
according to the P3-P4 and the source temperature.
CHASSIS Fan 1(~2) Point2 Temperature
Allows you to set the CHASSIS Fan 1(~2) Point2 Temperature. Conguration
options: [20] – [100]
CHASSIS Fan 1(~2) Point2 Duty Cycle (%)
Allows you to set the CHASSIS Fan 1(~2) Point2 Duty Cycle. Conguration
options: [20] – [100]
When the source temperature is lower than the temperature of P2, the duty cycle will
be dertermined according to the P1-P2 and the source temperature. When the source
temperature is higher than the temperature of P2, the duty cycle will be dertermined
according to the P2-P3 and the source temperature.
CHASSIS Fan 1(~2) Point1 Temperature
Allows you to set the CHASSIS Fan 1(~2) Point1 Temperature. Conguration
options: [20] – [100]
CHASSIS Fan 1(~2) Point1 Duty Cycle (%)
Allows you to set the CHASSIS Fan 1(~2) Point1 Duty Cycle. Conguration
options: [40] – [100]
When the source temperature is lower than the temperature of P1, the fan will operate at
the duty cycle of P1. When the source temperature is higher than the temperature of P1, the
duty cycle will be dertermined according to the P1-P2 and the source temperature.