RS520-E9 Series Server User Guide
E16289 Revised Edition V8 February 2020 Copyright © 2020 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Safety information..................................................................................................... viii About this guide........................................................................................................... x Chapter 1: Product Introduction 1.1 System package contents.......................................................................... 1-2 1.2 Serial number label.....................................................................................
Contents 2.8 Removable/optional components........................................................... 2-28 2.8.1 System fans............................................................................... 2-28 2.8.2 Slim optical drive (optional for RS520-E9-RS8)......................... 2-29 2.8.3 Redundant power supply module.............................................. 2-31 Chapter 3: Installation Options 3.1 Tool-less Friction Rail Kit..............................................................
Contents 5.5 5.6 5.7 5.8 Advanced menu........................................................................................ 5-11 5.5.1 Trusted Computing.................................................................... 5-12 5.5.2 ACPI Settings............................................................................. 5-12 5.5.3 Smart Settings........................................................................... 5-13 5.5.4 Super IO Configuration.........................................
Contents 5.11 Boot menu................................................................................................. 5-41 5.12 Tool menu.................................................................................................. 5-42 5.13 Save & Exit menu...................................................................................... 5-42 Chapter 6: RAID Configuration 6.1 6.2 Setting up RAID...........................................................................................
Chapter 7: Driver Installation 7.1 RAID driver installation.............................................................................. 7-2 7.1.1 Creating a USB flash drive with RAID drive................................. 7-2 7.1.2 Installing the RAID controller driver............................................. 7-2 7.2 Management applications and utilities installation................................. 7-5 7.3 Running the Support DVD................................................................
Safety information Electrical Safety • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. • When adding or removing any additional devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected.
Lithium-Ion Battery Warning CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Heavy System CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.
About this guide Audience This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server. Contents This guide contains the following parts: 1. Chapter 1: Product Introduction This chapter describes the general features of the server, including sections on front panel and rear panel specifications. 2.
Conventions To ensure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task. Typography Bold text Indicates a menu or an item to select.
xii
Chapter 1: Product Introduction Product Introduction This chapter describes the motherboard features and the new technologies it supports.
1.1 System package contents Check your system package for the following items. Model Name RS520-E9-RS12-E Chassis RS520-E9-RS8 ASUS 2U Rackmount Chassis Motherboard ASUS Z11PR-D16 Server Board Component 2 x 800W Redundant Power Supply 2 x 800W Redundant Power Supply 12 x Hot-swap 3.5-inch Storage Device Bays 8 x Hot-swap 3.5-inch Storage Device Bays 2 x Hot-swap 2.5-inch Storage Device Bays 2 x Hot-swap 2.
1.3 System specifications The ASUS RS520-E9 Series is a 2U barebone server system featuring the ASUS Z11PR-D16 Server Board. The server supports Intel® Xeon® Scalable Processor Family Series plus other latest technologies through the chipsets onboard. Model Name RS520-E9-RS12-E Motherboard RS520-E9-RS8 Z11PR-D16 2 x Socket P0 (LGA 3647) Processor Support 1st Gen Intel® Xeon® Processor Scalable Family 2nd Gen Intel® Xeon® Processor Scalable Family UPI 10.
Model Name RS520-E9-RS12-E 12 x 2.5” or 3.5” Hot-swap Storage Device Bays (supports 4 x NVMe)* Storage Bays I = internal A or S will be hotswappable 2 x 2.5” Hot-Swap Storage Device Bays on rear panel (supports SATA SSD only) 2 x M.2 2280/2260/2242 (supports SATA/PCIe M.2,SATA/PCIe RAID) *S ATA and SAS support requires an optional ASUS PIKE II card. Networking LAN Graphic VGA Auxiliary Storage Device Bay (Floppy / Optical Drive) RS520-E9-RS8 8 x 2.5” or 3.
Model Name RS520-E9-RS12-E RS520-E9-RS8 OS Support Please find the latest OS support from http://www.asus.com/ Regulatory Compliance BSMI, CE, CB, FCC Dimension (HH x WW x DD) 615mm x 444mm x 88mm (2U) 24.21” x 17.48” x 3.46” Net Weight Kg (CPU, DRAM & Storage device not included) 24.55 Kg 19.7 Kg Gross Weight Kg (CPU, DRAM & Storage device not included, Packing include) 30.1 Kg 27.
1.4 Front panel features The barebone server displays a simple yet stylish front panel with easily accessible features. The power and reset buttons, LED indicators, and USB ports for each Node are located on the front panel. Refer to the 1.7.1 Front panel LEDs section for the LED descriptions. Turn off the system power and detach the power supply before removing or replacing any system component. RS520-E9-RS8 Reset button Location button 2 x USB 3.
1.5 Rear panel features The rear panel includes the expansion slots, system power sockets, and rear fans. The I/O shields with openings for the rear panel connectors on the motherboard are also placed in the rear panel. 2.5-inch Bay 2 LAN port 2 VGA port 2.5-inch Bay 1 Redundant Power supply and Power cord connector Management LAN port 1* 2 x USB 3.0 ports Q-Code LED Serial port (optional) Expansion slot Power button LAN port 1 *This port is for ASUS ASMB9-iKVM only.
Asset tag The Asset tag is a simple but useful device that is conveniently located on the front panel of the server that you can pull out or easily slide back in. It has a piece of paper that allows you to write down important information about the server.
1.6 Internal features The barebone server includes the basic components as shown. RS520-E9-RS8 1. Redundant power supply 2. ASUS Z11PR-D16 Server Board 3. SATA/NVMe backplane 4. Slim optical drive (optional) 5. System fans 6. Asset Tag (hidden) 7. 8 x 3.5“ storage device bays 8. PCIE-NVME4-OCuLink card 9. 2 x 2.5” storage device bays Turn off the system power and detach the power supply before removing or replacing any system component.
RS520-E9-RS12-E 1. Redundant power supply 2. ASUS Z11PR-D16 Server Board 3. SATA/NVMe backplane 4. Front USB panel 5. System fans 6. Asset Tag (hidden) 7. 12 x 3.5“ storage device bays 8. PCIE-NVME4-OCuLink card 9. 2 x 2.5” storage device bays 10. Front I/O panel Turn off the system power and detach the power supply before removing or replacing any system component. The barebone server does not include a floppy disk drive.
1.7 LED information 1.7.
1.7.3 Bay status LED Front panel Storage Device Status LED (Red) Storage Device Activity LED (Green) LED Icon Storage Device Activity LED Display status Storage device not present GREEN ON No activity GREEN BLINKING 1. Read / Write data into the storage device 2. Locating Storage device has failed and should be swapped immediately RED ON Storage Device Status LED Description OFF 1. RAID rebuilding RED BLINKING 2. Locating 3.
1.7.2 LAN (RJ-45) LEDs ACT/LINK LED SPEED LED ACT/LINK LED SPEED LED ACT/LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection 1.7.4 Rear panel LEDs Power button with LED Q-Code LED* • The Q-Code LED provides the most probable cause of an error code as a starting point for troubleshooting. The actual cause may vary from case to case.
1.7.
Action PHASE PEI(Pre-EFI initialization) phase DXE(Driver Execution Environment) phase Normal boot BDS(Boot Device Selection) phase Operating system phase POST CODE 51 52 58 5A 5B 5C 5D 5F 60 61 68 69 70 71 7D 7E 7F 55 32 TYPE MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress Progress DESCRIPTION MRC_RH_PREVENTION MRC
1-16 Chapter 1: Product Introduction
Chapter 2: Hardware Information Hardware Information This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
2.1 Chassis cover 2.1.1 Removing the rear cover 1. Loosen the two thumbscrews on the rear panel to release the rear cover from the chassis. There is no need to remove the thumbscrews, just loosen them. Screws 2. Firmly hold the cover and slide it towards the rear panel for about half an inch until it is disengaged from the chassis. 3. Lift the cover from the chassis. The chassis is covered with a layer of film. Before starting up the system, remove the film to avoid overheating.
2.2 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA 3647 socket designed for the Intel® Xeon® Processors Scalable Family Series. Ensure that all power cables are unplugged before installing the CPU. 2.2.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components.
3. Align the triangle mark on the CPU with the triangle mark on the CPU Carrier (A), then install the CPU into the CPU Carrier until it clicks firmly into place (B), and then install the CPU Carrier into the heatsink until it clicks firmly in place (C). CPU Carrier Ensure that the triangle mark on the CPU matches the triangle mark on the CPU Carrier. Triangle mark 2 CPU 4. Align the CPU and CPU Carrier in the correct orientation, and then place the heatsinks on top of the CPU sockets.
6. Reinstall the air duct and secure the air duct screw. 2.3 System memory 2.3.1 Overview The motherboard comes with sixteen (16) Double Data Rate 4 (DDR4) Dual Inline Memory Modules (DIMM) sockets.
2.3.2 Memory Configurations You may install 4 GB, 8 GB, 16 GB, and 32 GB RDIMMs; 32 GB, and 64 GB LRDIMMs; and 64GB and 128GB LRDIMMs (3DS) into the DIMM sockets using the memory configurations in this section. • Refer to ASUS Server AVL for the updated list of compatible DIMMs. • Always install DIMMs with the same CAS latency. For optimum compatibility, it is recommended that you obtain memory modules from the same vendor. • Start installing the DIMMs in slot A1.
2.3.3 Installing a DIMM on a single clip DIMM socket Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. Unlock a DIMM socket by pressing the retaining clip outward. 2. Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket.
2.4 Storage devices The RS520-E9-RS8 system supports eight (8) 2.5” or 3.5” hot-swap storage devices, the RS520-E9-RS12-E system supports twelve (12) storage devices, and both support two (2) additional hot-swap 2.5” storage devices on the rear panel. The storage device installed in the bay connects to the motherboard SATA/NVMe ports via the SATA/NVMe backplane (SAS drives require an optional ASUS PIKE II card).
5. Place the 3.5” storage device into the tray then secure it with four screws. 6. Insert the tray and storage device assembly all the way into the depth of the bay until just a small fraction of the tray edge protrudes. When installed, the SATA/NVMe connector on the storage device connects to the SATA/ NVMe interface on the backplane. 7. Push the tray lever until it clicks and secures the tray in place. The tray is correctly placed when its front edge aligns with the bay edge. 8.
To install a 2.5” storage device to the front panel: 1. Push the spring lock to the right (A) then pull the tray lever outward (B) to release the tray. The tray ejects slightly after you pull out the lever. Tray lever Spring lock 2-10 2. Firmly hold the tray lever and pull the tray out of the bay. 3. Place the tray on a flat and stable surface. 4. Prepare the 2.5” storage device and the bundled set of screws.
5. Place the 2.5” storage device into the tray then secure it with four screws. 6. Insert the tray and storage device assembly all the way into the depth of the bay until just a small fraction of the tray edge protrudes. When installed, the SATA/NVMe connector on the storage device connects to the SATA/ NVMe interface on the backplane. 7. Push the tray lever until it clicks and secures the tray in place. The tray is correctly placed when its front edge aligns with the bay edge. 8.
To install a 2.5” storage device to the rear panel: 1. Press the spring lock to release the tray lever. Tray lever Spring lock 2-12 2. Firmly hold the tray lever then pull the tray out of the bay. 3. Release the screws on each side of the tray to release the tray metal beam.
4. Orient and place the 2.5” storage device into the tray. Ensure that the storage device is fitted firmly inside the tray and that the four screws of the storage device matches the four screws holes of the tray. Storage device screw hole Tray screw hole 5. Carefully insert the tray and push it all the way to the depth of the bay. Lock the secure tab to secure the tray in place. When installed, the connector on the storage device connects to the connector on the backplane. 6.
2.5 Expansion slot The barebone server comes with six (6) PCIE slots. PCIE slot 1 is pre-installed with a PCIENVME4-OCuLink card for installing NVME storage devices on Bay 1 to Bay 4. You need to remove these expansion card brackets if you want to install PCIE expansion cards. 2.5.1 Installing an expansion card to the PCIE slot To install an expansion card: 2-14 1. Remove the two screws on the bracket and put it aside. 2. Remove the bracket and put it aside.
3. Remove the screw that secures the metal cover to the chassis, then remove the metal cover then set it aside for future use. 4. Insert the expansion card into the PCIE slot. Ensure that the golden fingers are totally inserted into the slot. Secure it with the screw removed earlier. 5. Reinstall the bracket. Secure it with the two screws to complete the installation.
2.5.2 Installing an ASUS PIKE II card You can install an ASUS PIKE II card into PCIE slot 6 to allow your server system to support SAS drives on the front panel. 1. Remove the default cable from the motherboard. The illustrations shown above are for reference only. 2. Prepare the ASUS PIKE II card. If your expansion card is pre-installed with a proprietary card bracket, proceed to step 5. 3. 2-16 Card bracket Remove the two screws on the ASUS PIKE II card (A), then remove the card bracket (B).
4. 5. Secure the ASUS PIKE II card and the metal cover (proprietary card bracket) with the two screws. Metal cover Connect the mini-SAS HD cable to the ASUS PIKE II card. Connect to ASUS PIKE II connector 2 Connect to ASUS PIKE II connector 1 6. Install the ASUS PIKE II card and the metal cover assembly into PCIE slot 6. Ensure that the golden connectors of the ASUS PIKE II card is firmly seated in place. Refer to section 2.5.
2.5.3 Replacing the ASUS PCIE-NVME4-OCuLink card The ASUS PCIE-NVME4-OCuLink card pre-installed on the PCIE slot 1 allows your server system to support NVME storage devices on Bay 1 to Bay 4. To replace an ASUS PCIE-NVME4-OCuLink card: 2-18 1. Remove the two screws on the bracket and put it aside. 2. Remove the bracket and put it aside. 3. Remove the screw that secures the metal cover of the ASUS PCIENVME4-OCuLink card to the chassis, then remove the ASUS PCIE-NVME4OCuLink card.
4. Remove the OCuLink cables from its corresponding slots. OCuLink port 4 OCuLink port 3 OCuLink port 2 OCuLink port 1 5. Prepare the replacement ASUS PCIE-NVME4-OCuLink card. 6. Reconnect the OCuLink cables to its corresponding slots.
2-20 7. Insert the ASUS PCIE-NVME4-OCuLink card into the PCIE slot. Ensure that the golden fingers are totally inserted into the slot. Secure it with the screw removed earlier. 8. Reinstall the bracket. Secure it with the two screws to complete the installation.
2.5.4 Configuring an expansion card After installing the expansion card, configure it by adjusting the software settings. 1. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for information on BIOS setup. 2. Assign an IRQ to the card. Refer to the following tables. 3. Install the software drivers for the expansion card.
2.5.5 Installing an M.2 expansion card You can install an M.2 expansion card on the provided M.2 slot onboard. To install an M.2 expansion card: 2-22 1. Remove the screw on the M.2 socket and put it aside. 2. Prepare your M.2 expansion card. 3. Align and insert the M.2 card into the M.2 slot onboard as shown. 4. Secure the M.2 card with a screw to complete the installation. • Please pay attention when removing the screw, the stand screw might be removed together with it. • Ensure that the M.
2.5.6 Installing a Mezzanine card You can install a supported Mezzanine card on the onboard slot. To install a Mezzanine card: 1. Remove the slot bay from the Mezzanine card expansion slot. 2. Prepare your Mezannine card and the signal cable. Connect the signal transmission end (white) to the AUXLED_CON header on the card. AUXLED_CON1 3.
4. Secure the Mezzanine card with the four (4) bundled screws. 5. Connect the signal end (black) to the OCP_LED1 header on the motherboard. OCP_LED1 The two ends of the signal cable are different in size and color for easy recognition. Please refer to your exact cable.
2.6 Cable connections • The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you need to remove pre‑installed components to install additional devices. • Refer to Chapter 4 for detailed information on the connectors. Pre-connected system cables 1. 24-pin ATX power connector (from power supply to motherboard) 2. 8-pin 12V power connector (from power supply to motherboard) 3. System fan connector (from motherboard to system fans) 4.
2.
RS520-E9-RS12-E Connects a 8-pin plug from motherboard Connects the data cable connected to the optional ASUS PIKE II card OCUPCIE4 PWR1 Reserved for future expansions MSAS_HD1 OCUPCIE1 MSAS_HD2 OCUPCIE2 MSAS_HD3 OCUPCIE3 Connects the data cable connected to the ASUS PCIE-NVME4-OCuLink card ASUS RS520-E9 Series 2-27
2.8 Removable/optional components This section explains how to install optional components into the system and covers the following components: 1. System fans 2. Slim type optical drive (optional) 3. Redundant power supply module (optional) Ensure that the system is turned off before removing any components. 2.8.1 System fans To uninstall the system fans: 1. Hold two levers on both sides of the fan, then lift the fan to remove. 2. Repeat steps 1 to uninstall the other system fans.
2.8.2 Slim optical drive (optional for RS520-E9-RS8) To install the optional optical drive: 1. Remove 2 screws that secure the slim optical drive cover to the chassis. 2. Secure two screws on each side of the optical drive to secure it into the expansion bracket. 3. Place the slim optical drive into the expansion bay. 4. Ensure the expansion tray is completely inserted into the bay. (The drive tray is correctly placed when its front edge aligns with the bay edge.
To remove or uninstall the slim type optical disk drive: 2-30 1. Locate the optical drive eject latch at the back of the optical drive bay. 2. Press the optical drive eject latch to the right then push the slim type optical drive towards the front panel.
2.8.3 Redundant power supply module To replace a failed redundant power supply module: • Ensure that the system is turned off before removing any components. • Touch any metal surface to release static electricity. • Use power supply module with the same model and style. To install the second redundant power supply module: 1. Press the latch to the left (A). 2. Remove the metal cover from the chassis (B). 3. Prepare the second redundant power supply module.
2-32 Chapter 2: Hardware Information
Chapter 3: Installation Options Installation Options This chapter describes how to install the optional components and devices into the barebone server.
3.1 Tool-less Friction Rail Kit The tool-less design of the rail kit allows you to easily install the rack rails into the server rack without the need for additional tools. The kit also comes with a metal stopping bracket that can be installed to provide additional support and stability to the server.
2. Select a desired space and place the appropriate rack rail (left and right) on opposite positions on the rack. A 1U space consists of three square mounting holes with two thin lips on the top and the bottom. 1U 3. Secure the rail components to the rail using the bundled screws. 4 Press the spring lock ( ) then insert the studs into the selected square mounting holes on the rack post. 5. 6.
8. Lift the server chassis and insert it into the rack rail. • Ensure that the rack rail cabinet and the rack posts are stable and standing firmly on a level surface. • We strongly recommend that at least two able-bodied persons perform the steps described in this guide. • We recommend the use of an appropriate lifting tool or device, if necessary. RS520-E9-RS8 Front View 4 3 2 1 RS520-E9-RS12-E Front View Ensure to include the side knots on the two sides of the server in the rack rail holders.
3.2 Rail kit dimensions 43.6mm 900mm 43.
3-6 Chapter 3: Installation Options
Chapter 4: Motherboard Information Motherboard Information This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors.
4.
Layout contents Internal connectors / Sockets / Jumpers / LEDs Page 1. CPU, front, and rear fan connectors (4-pin FRNT_FAN1-7; REAR_FAN1-2) 4-15 2. TPM connector (14-1 pin TPM1) 4-16 3. Auxiliary panel connector (20-2 pin AUX_PANEL1, 20-pin AUX_PANEL2) 4-19 4. Chassis Intrusion (2-pin INTRUSION1-2) 4-21 5. USB 2.0 connector (10-1 pin USB78; USB56) 4-14 6. Power Supply SMBus connector (5-pin PSUSMB1) 4-24 7. ATX power connectors (24-pin EATXPWR; 8-pin EATX12V1; 8-pin EATX12V2) 4-17 8.
4.2 1. Jumpers Clear RTC RAM (3-pin CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. Turn OFF the computer and unplug the power cord. 2. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. 3. LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allow you to enable or disable the onboard Intel® I350-AM2 Gigabit LAN1/2 controller. Set to pins 1–2 to activate the Gigabit LAN feature.
4. ME firmware force recovery setting (3-pin ME_RCVR1) This jumper allows you to force Intel® Management Engine (ME) boot from recovery mode when ME becomes corrupted. 5. Baseboard Management Controller setting (3-pin BMC_EN1) This jumper allows you to enable (default) or disable on-board BMC. Ensure to set this BMC jumper to enabled to avoid system fan control and hardware monitor error.
6. DDR4 thermal event setting (3-pin DIMMTRIP1; DIMMTRIP2) This jumper allows you to enable or disable DDR4 DIMM thermal sensing event pin. 7. PCH_MFG1 setting (3-pin PCH_MFG1) This jumper allows you to update the BIOS ME block.
8. Smart Ride Through (SmaRT) setting (3-pin SMART_PSU1) This jumper allows you to enable or disable the Smart Ride Through (SmaRT) function. This feature is enabled by default. Set to pins 2-3 to disable it. When enabled, SmaRT allows uninterrupted operation of the system during an AC loss event. 9. LANNCSI setting (3-pin LANNCSI_SEL1) This jumper allows you to select which LAN NCSI to function.
10. DMLAN setting (3-pin DM_IP_SEL1) This jumper allows you to select the DMLAN setting. Set to pins 2-3 to force the DMLAN IP to static mode (IP=10.10.10.10, submask=255.255.255.0).
4.3 1. Internal LEDs Standby Power LED (SBPWR1) The motherboard comes with a standby power LED. The green LED lights up to indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard LED. 2.
3. Storage device activity LED (HDDLED1) This LED is for the storage devices connected to the onboard SATA, or SATA/SAS add-on card. The read or write activities of any device connected to the onboard SATA, or SATA/SAS add-on card causes the rear panel LED to light up. 4. Message LED (MESLED1) This onboard LED lights up to orange when there is a BMC event log is generated.
5. BMC LED (BMCLED1) The BMC LED blinks to indicate that the on-board BMC is functional. 6. CATERR1 LED (CATERR1) The CATERR1 LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate.
4.4 1. Internal connectors Serial ATA connectors (7-pin SSATA1-3) These connectors, controlled by Intel® C621 chipset, are for the Serial ATA signal cables for Serial ATA hard disk drives (SATA 1 connector is used for the optical drive by default). 2. Mini-SAS HD connector (ISATA1-2) This motherboard comes with mini Serial Attached SCSI (SAS) HD connectors, the storage technology that supports Serial ATA. Each connector supports up to four devices.
3. USB 2.0 connector (10-1 pin USB78; USB56) This connector is for USB 2.0 ports. Connect the USB module cable to the connector, and then install the module to a slot opening at the back of the system chassis. The USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. The USB port module is purchased separately. 4. USB 3.0 connector (20-1 pin USB3_34) This connector allows you to connect a USB 3.0 module for additional USB 3.0 front or rear panel ports.
5. CPU, front, and rear fan connectors (4-pin FRNT_FAN1-7; REAR_FAN1-2) The fan connectors support cooling fans of 0.8A–1.0A (12 W max.) or a total of 6.4 A–8.0 A (96 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, making sure that the black wire of each cable matches the ground pin of the connector. DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components.
7. Serial port connector (10-1 pin COM1) This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis. The COM module is purchased separately. 8. TPM connector (14-1 pin TPM1) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data.
9. ATX power connectors (24-pin EATXPWR1; 8-pin EATX12V1; 8-pin EATX12V2) These connectors are for the ATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • DO NOT forget to connect the 24-pin and the 8-pin power plugs; otherwise, the system will not boot up.
10. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1. System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. 2. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
11. Auxiliary panel connector (20-2 pin AUX_PANEL1, 20-pin AUX_PANEL2) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 1. Front panel SMB (6-1 pin FPSMB) This 6-1 pin connector is for the front panel SMBus cable. 2. LAN activity LED (2-pin LAN1_LED, LAN2_LED) This 2-pin connector is for the Gigabit LAN activity LEDs on the front panel. 3.
12. VGA connector (16-pin VGA_HDR1) This connector supports the VGA High Dynamic-Range interface. 13. Storage device activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card. The read or write activities of any device connected to the SATA or SAS add-on card causes the front panel LED to light up.
14. Chassis Intrusion (2-pin INTRUSION1-2) These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch. When you remove any chassis component, the sensor triggers and sends a high level signal to these leads to record a chassis intrusion event. The default setting is to short the CHASSIS# and the GND pin by a jumper cap to disable the function. 15. VPP_I2C1 connector (10-1 pin VPP_I2C1) This connector is used for the Intel VMD function and sensor readings.
16. Mezzanine PCIE card connectors (MEZZPCIE1-2) The MEZZPCIE1-2 connector supports Open Compute Project (OCP) cards. 17. Micro SD card slot (MSD1) Your motherboard supports SD Memory Card v2.00 (SDHC) / v3.00 (SDXC). Disconnect all power (including redundant PSUs) from the existing system before you add or remove a Memory Card, then reboot the system to access the Memory Card. Some memory cards may not be compatible with your motherboard.
18. VROC KEY connector (4-pin VROC_KEY) This connector allows you to connect a KEY module to enable additional CPU RAID functions with Intel® CPU RSTe. The KEY module is purchased separately. 19. M.2 (NGFF) card connectors (NGFF1-2) These connectors allow you to install M.2 devices. This connector supports type 2242 / 2260 / 2280 devices on both PCI-E and SATA interface. The M.
20. Power Supply SMBus connector (5-pin PSUSMB1) This connector allows you to connect SMBus (System Management Bus) to the PSU (power supply unit) to read PSU information. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface. This connector functions only when you enable BMC_EN1. 21. OCP LAN Activity LED connector (4-1 pin OCP_LED1) OCP LAN LED connector supports OCP LAN card Active LED.
Chapter 5: BIOS Setup BIOS Setup This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
5.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. ASUS CrashFree BIOS 3 To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted. 2. ASUS EzFlash Updates the BIOS using a USB flash disk. 3. BUPDATER Updates the BIOS in DOS mode using a bootable USB flash disk drive. Refer to the corresponding sections for details on these utilities.
5.1.2 ASUS EZ Flash Utility The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash Utility: 1. Insert the USB flash disk that contains the latest BIOS file into the USB port. 2. Enter the BIOS setup program. Go to the Tool menu then select ASUS EZ Flash Utility. Press . ASUS Tek.
5.1.3 BUPDATER utility The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown. The BUPDATER utility allows you to update the BIOS file in the DOS environment using a bootable USB flash disk drive with the updated BIOS file. Updating the BIOS file To update the BIOS file using the BUPDATER utility: 1. Visit the ASUS website at www.asus.com and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable USB flash disk drive.
4. The utility verifies the file, then starts updating the BIOS file. ASUS Tek. EzFlash Utility Current Platform Platform : Z11PR-D16 Version : 0203 Build Date :06/06/2017 New Platform Platform : Z11PR-D16 Version : 0205 Build Date :07/07/2017 Start programming the Flash. DO NOT SHUTDOWN THE SYSTEM!!! Write ... 25% DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the DOS prompt after the BIOS update process is completed.
5.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 5.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
5.2.1 BIOS menu screen Menu items 5.2.
5.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (such as Advanced) on the menu bar have their respective menu items. 5.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item then press . 5.2.
5.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time, language, and security settings. 5.3.1 System Date [Day xx/xx/xxxx] Allows you to set the system date. 5.3.2 System Time [xx:xx:xx] Allows you to set the system time.
5.4 Performance Tuning menu The Performance Tuning menu items allow you to change performance related settings for different scenarios. Optimized Performance Setting [Default] Allows you to select performance settings for different scenarios. [Default] Default settings. [By Benchmark] O ptimize for different kinds of benchmarks. Select this option, then select a benchmark type from the >> list. [By Workload] Optimize for different kinds of workloads.
Engine Boost [Disabled] Enable this item to boost the CPU’s frequency. Configuration options: [Disabled] [Level1] [Level2] [Level3(Max)] Operate with an ambient temperature of 25°C or lower for optimized performance. Power Balancer [Disabled] Select [Enable Auto] to dynamically adjust the frequency of all CPU cores based on the current utilization, delivering better performance per watt for improved system energy efficiency. Configuration options: [Disabled] [Enable Auto] [Enable Manual] 5.
5.5.1 Trusted Computing Configuration Security Device Support [Disabled] Allows you to enable or disable the BIOS support for security device. Configuration options: [Disabled] [Enabled] 5.5.2 ACPI Settings Enable ACPI Auto Configuration [Disabled] Allows you to enable or disable the BIOS ACPI Auto Configuration. Configuration options: [Disabled] [Enabled] Enable Hibernation [Enabled] Allows you to enable or disable the ability of the system to hibernate (OS/Sleep State).
5.5.3 Smart Settings SMART Self Test [Enabled] Allows you to run SMART Self Test on all HDDs during POST. Configuration options: [Disabled] [Enabled] 5.5.4 Super IO Configuration Serial Port 1 Configuration Allows you to set the parameters of Serial Port 1. Serial Port [Enabled] Allows you to enable or disable Serial Port. Configuration options: [Disabled] [Enabled] The following item appears only when you set Serial Port to [Enabled].
5.5.5 Serial Port Console Redirection COM1/COM2 Console Redirection [Disabled] Allows you to enable or disable the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings These items become configurable only when you enable the Console Redirection item. The settings specify how the host computer and the remote computer (which the user is using) will exchange data.
Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [None] None [Even] parity bit is 0 if the num of 1’s in the data bits is even [Odd] parity bit is 0 if num of 1’s in the data bits is odd [Mark] parity bit is always 1 [Space] parity bit is always 0 Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.) The standard setting is 1 stop bit.
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Console Redirection [Disabled] Allows you to enable or disable the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port.
5.5.6 Onboard LAN Configuration Onboard I350 LAN Configuration Intel LAN1 Enable [Enabled] Allows you to enable or disable the Intel LAN. Configuration options: [Disabled] [Enabled] The following items appear only when Intel LAN1 Enable is set to [Enabled]. Intel LAN 1 ROM Type [PXE] Allows you to select the Intel LAN ROM type. Configuration options: [PXE] [iSCSI] [Disabled] Intel LAN2 Enable [Enabled] Allows you to enable or disable the Intel LAN.
5.5.7 APM Allows you to configure the Advance Power Management (APM) settings. Restore AC Power Loss [Last State] When set to [Power Off], the system goes into off state after an AC power loss. When set to [Power On], the system will reboot after an AC power loss. When set to [Last State], the system goes into either off or on state, whatever the system state was before the AC power loss.
5.5.8 PCI Subsystem Settings Allows you to configure PCI, PCI-X, and PCI Express Settings. Load RT32 Image [Enabled] This option allows you to enable or disable RT32 Image Loading. Configuration options: [Disabled] [Enabled] Above 4G Decoding [Disabled] Allows you to enable or disable 64-bit capable devices to be decoded in above 4G address space. It only works if the system supports 64-bit PCI decoding.
PCI Express Link Register Settings ASPM Support [Disabled] Allows to set the ASPM level. Configuration options: [Disabled] [Auot] [Force L0s] [Force L0s] Force all links to L0s state. [Auto] BIOS auto configure. [Disabled] Disabled ASPM. Unpopulated Links [Keep Link ON] In order to save power, software will disable unpopulated PCI Express links, if this option set to Disabled.
5.5.9 USB Configuration Legacy USB Support [Enabled] Allows you to enable or disable Legacy USB device support. Configuration options: [Enabled] [Disabled] [Auto] USB Mass Storage Driver Support [Enabled] Allows you to enable or disable the USB Mass Storage driver support. Configuration options: [Disabled] [Enabled] Mass Storage Devices AMI Virtual CDROM0-2 / Floppy / HDisk0 1.00 [Auto] Allows you to select the mass storage device emulation type.
5.5.10 CSM Configuration CSM Support [Enabled] This option allows you to enable or disable CSM Support. Configuration options: [Disabled] [Enabled] The following item appears only when CSM Support is set to [Enabled]. GateA20 Active [Upon Request] This allows you to set the GA20 option. Configuration options: [Upon Request] [Always] Option ROM Messages [Force BIOS] This allows you to set the display mode for option ROM.
5.5.11 NVMe Configuration 5.5.12 Network Stack Configuration This page will display the NVMe controller and drive information. Network stack [Disabled] Enables or disables the network stack feature. Configuration options: [Disable] [Enable] The following item appears only when Network stack is set to [Enabled]. Ipv4 PXE Support [Disabled] Enables or disables the Ipv4 PXE Boot Support. If disabled, Ipv4 PXE boot option will not be created.
5.5.13 iSCSI Configuration Allows you to configure the iSCSi parameters. 5.6 Platform Configuration menu The IntelRCSetup menu items allow you to change the platform settings.
5.6.1 PCH Configuration PCH Devices DeepSx Power Policies [Disabled] Allows you to configure the DeepSx Mode configuration. Configuration options: [Disabled] [Enabled in S5] [Enabled in S4 and S5] GP27 Wake From DeepSx [Disabled] Allows you to enable or disable GP27 Wake From DeepSx. Configuration options: [Disabled] [Enabled] PCI Express Configuration PCI-E ASPM Support (Global) [L1 Only] Allows you to select ASPM support for all downstream devices.
SATA Port 1-8 Port 1-8 Allows you to enable or disable the SATA port. Configuration options: [Disabled] [Enabled] PCH sSATA Configuration sSATA Controller [Enabled] Allows you to enable or disable the sSATA Controller. Configuration options: [Disabled] [Enabled] Configure sSATA as [AHCI] Allows you to identify the SATA port connected to Solid State Drive or Hard Disk Drive.
The following items appears only when the USB Per-Connector Disable is set to [Enabled]. USB_1-8 [Enabled] Configuration options: [Disabled] [Enabled] USB3_1-5 [Enabled] Configuration options: [Disabled] [Enabled] Security Configuration SMM BIOS Write Protect [Enabled] Allows you to enable or disable SMM BIOS Write Protect. Configuration options: [Disabled] [Enabled] 5.6.2 Miscellaneous Configuration Active Video [Offboard Device] Allows you to select the video type.
5.6.4 Runtime Error Logging Support Runtime Error Logging System Errors [Enabled] This item allows you to enable or disable System Errors. Configuration options: [Disabled] [Enabled] Whea Settings Whea Support [Disabled] This item allows you to enable or disable the WHEA support. Configuration options: [Disabled] [Enabled] 5.7 Socket Configuration menu The IntelRCSetup menu items allow you to change the socket settings.
5.7.1 Processor Configuration Hyper Threading [ALL] [Enabled] Allows you to enable or disable the Hyper-Threading Technology function. When disabled, only one thread per activated core is enabled. Configuration options: [Disabled] [Enabled] Enable Intel(R) TXT Support [Disabled] Forces the XD feature log to always return 0 when disabled. Configuration options: [Disabled] [Enabled] VMX [Enabled] Enables the Vanderpool Technology. Takes effect after reboot.
Adjacent Cache Prefetch [Enabled] This Item allows you to turn on/off prefetching of adjacent cache lines. Configuration options: [Disabled] [Enabled] DCU Streamer Prefetcher [Enabled] This Item allows you to enable or disable prefetcher of next L1 data line. Configuration options: [Disabled] [Enabled] DCU IP Prefetcher [Enabled] This Item allows you to enable or disable prefetch of next L1 line based upon sequential load history.
5.7.3 UPI Configuration UPI General Configuration UPI Status This item displays information about the UPI status. Link Speed Mode [Fast] This item allows you to select the UPI link speed as either the fast mode or slow mode. Configuration options: [Slow] [Fast] Link Frequency Select [Auto] This item allows for selecting the UPI link frequency. Configuration options: [Auto] [9.6 GB/s] [10.
5.7.4 Memory Configuration Enforce POR [Auto] Allows you to enforce POR restrictions for DDR4 frequency and voltage programming. Configuration options: [Auto] [POR] [Disabled] Memory Frequency [Auto] Allows you to select the memory frequency setting. Configuration options: [Auto] [1800] - [3000-OvrClk] Data Scrambling for DDR4 [Auto] Allows you to enable or disable data scrambling.
Rank Interleaving [Auto] Select different rank interleaving setting. Configuration options: [Auto] [1-way Interleave] [2-way Interleave] [4-way Interleave] [8-way Interleave] Memory RAS Configuration Mirror Mode [Disabled] Allows you to select Mirror Modes. Mirror Mode will set entire 1LM/2LM memory in system to be mirrored, consequently reducing the memory capacity by half. Enabling Mirror Mode will disable XPT Prefetch.
5.7.5 IIO Configuration Socket1 Configuration This item allows you to configure settings related to the corresponding PCIE port. Intel(R) VT for Directed I/O (VT-d) Intel(R) VT for Directed I/O (VT-d) [Disabled] Allows you to enable or disable the Intel Virtualization Technology for Directed I/O. Configuration options: [Disabled] [Enabled] PCI Express Global Options PCI-E ASPM Support (Global) [Per-Port] Allows you to enable or disable ASPM support for all downstream devices.
5.7.6 Advanced Power Management Configuration CPU P State Control Boot performance mode [Max Performance] Allows you to switch between Boot performance mode. Configuration options: [Max Performance] [Max Efficient] [Set by Intel Node Manager] Energy Efficient Turbo [Enabled] Allows you to enable or disable Energy Efficient Turbo. Configuration options: [Disabled] [Enabled] Turbo Mode [Enabled] Allows you to enable or disable Turbo Mode.
CPU Thermal Control CPU T-State Control Software Controlled T-States [Disabled] Allows you to enable or disable Software Controlled T-States. Configuration options: [Disabled] [Enabled] CPU - Advanced PM Tuning Energy Perf BIAS Power Performance Tuning [OS Controls EPB] Configuration options: [OS Controls EPB] [BIOS Controls EPB] The following item appears only when you set Power Performance Tuning to [OS Controls EPB]. PECI PCS EPB [OS Controls EPB] This option controls whether PECI has control over EPB.
5.8 Event Logs menu The Event Logs menu items allow you to change the event log settings and view the system event logs. 5.8.1 Change Smbios Event Log Settings Press to change the Smbios Event Log configuration. All values changed here do not take effect until computer is restarted. Enabling/Disabling Options Smbios Event Log [Enabled] Change this to enable or disable all features of Smbios Event Logging during boot.
5.9 Server Mgmt menu The Server Management menu displays the server management status and allows you to change the settings. OS Watchdog Timer [Disabled] This item allows you to start a BIOS timer which can only be shut off by Intel Management Software after the OS loads. Configuration options: [Disabled] [Enabled] The following items is configurable only when the OS Watchdog Timer is set to [Enabled]. OS Wtd Timer Timeout [10 minutes] Allows you to configure the length fo the OS Boot Watchdog Timer.
5.10 Security menu This menu allows a new password to be created or a current password to be changed. The menu also enables or disables the Secure Boot state and lets the user configure the System Mode state. Administrator Password To set an administrator password: 1. Select the Administrator Password item and press . 2. From the Create New Password box, key in a password, then press . 3. Confirm the password when prompted. To change an administrator password: 1.
User Password To set a user password: 1. Select the User Password item and press . 2. From the Create New Password box, key in a password, then press . 3. Confirm the password when prompted. To change a user password: 1. Select the User Password item and press . 2. From the Enter Current Password box, key in the current password, then press . 3. From the Create New Password box, key in a new password, then press . 4. Confirm the password when prompted.
5.11 Boot menu The Boot menu items allow you to change the system boot options. Bootup NumLock State [On] Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On] Boot Logo Display [Auto] Allows you to enable or disable the full screen logo display feature. Configuration options: [Auto] [Full Screen] [Disabled] POST Report [5 sec] Allows you to set the desired POST Report waiting time from 1 to 10 seconds.
5.12 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. IPMI Hardware Monitor Allows you to run the IPMI hardware monitor. Start EZ Flash Allows you to run ASUS EZ Flash BIOS ROM Utility when you press . Refer to the ASUS EZ Flash Utility section for details. 5.13 Save & Exit menu The Save & Exit menu items allow you to save or discard your changes to the BIOS items.
Chapter 6: RAID Configuration RAID Configuration This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities.
6.1 Setting up RAID The motherboard supports the Intel® Rapid Storage Technology enterprise Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS and Linux). 6.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage.
6.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. Install the SATA hard disks into the drive bays following the instructions in the system user guide. 2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. 3.
6.2 Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM Utility The Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge.
6.2.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select 1. Create RAID Volume and press . 2. Key in a name for the RAID set and press . Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Strips) Disks: Select Disks Strip Size: 128KB Capacity: 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only) then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7.
6.2.2 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . 2. From the Delete Volume Menu, press the up/down arrow keys to select the RAID set you want to delete then press . Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
6.2.3 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . 2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want to reset, then press . A small triangle before the Port number marks the selected drive.
6.2.4 Exiting the Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility To exit the utility: 1. From the utility main menu, select 4. Exit then press . 2. Press to exit or press to return to the utility main menu. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 6.2.5 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. When done, the status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume RAID Volumes: ID Name 1 Volume0 [ MAIN MENU ] 3. Reset Disks to Non-RAID 4.
6.2.6 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multiRAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utility. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. Reboot the system and press to enter the BIOS setup utility during POST. 2. Go to the Boot menu and select the boot option priority. 3.
6.3 Intel® Rapid Storage Technology enterprise (Windows) The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. Please refer to the installation instructions in Chapter 7.
6.3.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select Create Volume and select volume type. 2. Click Next. 3. Enter a name for the RAID set, then select the array disks. 4. Select Volume Size tab, you can drag the bar to decide the volume size. 5. Click Next. • If you do not want to keep the data on one of the selected disks, select NO when prompted. • If you want to Enable volume write-back cache or Initialize volume, click Advanced.
6. Confirm the volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can continue using other applications during this time. 7. Wait until the process is completed, then click OK when prompted. You still need to partition your new volume using Windows Disk Management before adding any data. The RAID set is displayed in the Volumes list and you can change the settings in Volume Properties.
6.3.2 Changing a Volume Type To change the volume type in Volume Properties: 1. Click the SATA array items you want to change in Volumes field. 2. From the Volume Properties field, select Type: RAID 1 Change type. 3. You can change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and click OK. The available stripe size values range from 4 KB to 128 KB.
6.3.3 Deleting a volume Be cautious when deleting a volume. You will lose all data on the hard disk drives. Before you proceed, ensure that you back up all your important data from your hard drives. To delete a volume: 6-16 1. From the utility main menu, select the volume (ex. Volume_0000) in Volumes field you want to delete. 2. Select Delete volume in Volume Properties field. The following screen appears. 3.
6.3.4 Preferences System Preferences Allow you to set to show the notification area icon and show system information, warning, or errors here.
6-18 Chapter 6: RAID Configuration
Chapter 7: Driver Installation Driver Installation This chapter provides the instructions for installing the necessary drivers for different system components in the Windows® Operating Systems.
7.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 7.1.1 Creating a USB flash drive with RAID drive When installing Windows® Server OS, you can load the RAID driver from a USB flash drive.
3. Click Load Driver. 4. A message appears reminding you to insert the installation media containing the driver of the RAID controller driver (the installation media can be a CD, DVD, or USB flash drive). • If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive. • Or you may connect a USB flash drive containing the RAID controller driver. Click Browse to continue. 5.
7. When the system finishes loading the RAID driver, • Replace the motherboard Support DVD with the Windows Server installation disc. • Remove the USB flash drive. Select the drive to install Windows and click Next. 8. 7-4 Setup then proceeds with the OS installation. Follow screen instructions to continue.
7.2 Management applications and utilities installation The support DVD that is bundled with your motherboard contains drivers, management applications, and utilities that you can install to maximize the features of your motherboard. 7.3 1. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for the latest updates on software and utilities. 2. The support DVD is supported on Windows® Server 2012 R2 and Windows® Server 2016.
7.3.1 Drivers menu tab The Drivers Menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices. 7.3.2 Utilities menu tab The Utilities menu displays the software applications and utilities that the motherboard supports.
7.3.3 Manual menu The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide. You need an internet browser installed in your OS to view the User Guide. 7.3.4 Contact information menu The Contact menu displays the ASUS contact information, e-mail addresses, and useful links if you need more information or technical support for your motherboard.
7.4 Intel® chipset device software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. Restart the computer, and then log on with Administrator privileges. 2. Insert the motherboard/system support DVD into the optical drive.
5. Read the License Agreement and click Accept to continue the process. 6. Read the Readme File Information and click Install to start the installation process. 7. Click Restart Now to complete the setup process.
7.5 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. Restart the computer, and then log on with Administrator privileges. 2. Insert the motherboard/system support DVD into the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
5. Click Install to start the installation process. 6. Click Finish to complete the installation.
7.6 I nstalling the Intel® I350-AM2 Gigabit Adapters driver This section provides the instructions on how to install the Intel® I350-AM2 Gigabits Adapter Driver on the system. To install the Intel® I350-AM2 Gigabit Adapters Driver on the Windows® operating system: 1. Restart the computer. 2. Log on with Administrator privileges. 3. Insert the motherboard/system support DVD to the optical drive.
6. Click Install to start the installation. 7. When the installation is done, press Finish to complete the installation.
7.7 Intel® Rapid Storage Technology enterprise installation This section provides the instructions on how to install the Intel® Rapid Storage Technology enterprise on the system. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. To install the Intel® Rapid Storage Technology enterprise utility: 7-14 1. Restart the computer, and then log on with Administrator privileges. 2.
5. Read the Warning message and click Next to continue. 6. Read the License Agreement and click Accept to continue the process. 7. Select the destination folder and click Next to continue.
7-16 8. Tick the features that you would like to install and click Next to continue. 9. Click Install to start the installation process. 10. Click Restart Now to complete the setup process.
Appendix Appendix This appendix includes additional information that you may refer to when configuring the motherboard.
Z11PR-D16 block diagram DDR4 AEP DIMM/RDIMM * 2 Channel G DDR4 1866/2133/2400/2667 Channel A DDR4 1866/2133/2400/2667 DDR4 AEP DIMM/RDIMM * 1 Channel H DDR4 1866/2133/2400/2667 Channel B DDR4 1866/2133/2400/2667 DDR4 AEP DIMM/RDIMM * 1 DDR4 AEP DIMM/RDIMM * 1 Channel J DDR4 1866/2133/2400/2667 Channel C DDR4 1866/2133/2400/2667 DDR4 AEP DIMM/RDIMM * 1 DDR4 AEP DIMM/RDIMM * 2 Channel K DDR4 1866/2133/2400/2667 CPU2 CPU1 Channel D DDR4 1866/2133/2400/2667 DDR4 AEP DIMM/RDIMM * 1 Channel L DD
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Canadian Department of Communications Statement This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. REACH Complying with the REACH (Registration, Evaluation, Authorisation, and Restriction of Chemicals) regulatory framework, we published the chemical substances in our products at ASUS REACH website at http://csr.asus.com/english/REACH.htm. DO NOT throw the motherboard in municipal waste.
ASUS contact information ASUSTeK COMPUTER INC. Address Telephone Fax Web site Technical Support Telephone Fax Online Support 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan +886-2-2894-3447 +886-2-2890-7798 https://www.asus.com +86-21-38429911 +86-21-58668722 ext: 9101 https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=en ASUSTeK COMPUTER INC. (Taiwan) Address Telephone Fax Web site 4F, No. 150, Li-Te Rd.
ASUS contact information ASUS COMPUTER INTERNATIONAL (America) Address 48720 Kato Rd., Fremont, CA 94538, USA Fax +1-510-608-4555 Web site https://www.asus.com/us/ Technical Support Support fax General support Online support +1-812-284-0883 +1-812-282-2787 https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=en-us ASUS COMPUTER GmbH (Germany and Austria) Address Fax Web site Harkort Str. 21-23, 40880 Ratingen, Germany +49-2102-959911 https://www.asus.
ASUS contact information ASUS Holland BV (The Netherlands) Address Web site Technical Support Telephone Fax E-mail Online Support Marconistraat 2, 7825GD EMMEN, The Netherlands https://www.asus.com/nl/ +31-(0)591-5-70292 +31-(0)591-666853 advance.rma.eu@asus.com https://www.asus.com/support/Product/ContactUs/Services/ questionform/?lang=nl-nl ASUS Polska Sp. z o.o. (Poland) Address Web site Technical Support Telephone Online Support Ul.
A-8 Appendix