RS920-E7/RS8 RS926-E7/RS8 2U Rackmount Server User Guide
E7284 First Edition March 2012 Copyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Notices......................................................................................................... vii Safety information....................................................................................... ix About this guide........................................................................................... x Chapter 1: 1.1 1.2 1.3 Product introduction System package contents............................................................ 1-2 Serial number label............
Contents Chapter 3: 3.1 3.1.1 3.1.2 Chapter 4: Attaching the fixing latches to the server......................... 3-2 Mounting the server to the rack....................................... 3-5 Motherboard information 4.1 Motherboard layout....................................................................... 4-2 4.3 Internal connectors....................................................................... 4-8 4.2 4.4 Jumpers........................................................................
Contents 5.4.6 PCI Subsystem Settings................................................ 5-22 5.4.8 USB Configuration......................................................... 5-27 5.4.7 5.4.9 5.4.10 5.4.11 5.4.12 5.4.13 5.4.14 5.4.15 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.4.16 5.5.1 5.5.2 ACPI Settings................................................................. 5-29 WHEA Configuration...................................................... 5-30 APM setting.................................................
Contents 6.2.7 6.2.8 Selecting the boot drive from a RAID set....................... 6-22 Enabling WriteCache..................................................... 6-23 6.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility...................................................................... 6-24 6.3.1 Creating a RAID set....................................................... 6-26 6.3.3 Deleting a RAID set....................................................... 6-29 6.3.2 6.3.
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
REACH Information Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we publish the chemical substances in our products at ASUS REACH website at http://csr.asus.com/english/REACH.htm. ASUS Recycling/Takeback Services ASUS recycling and takeback programs come from our commitment to the highest standards for protecting our environment.
Safety information Electrical Safety • • • • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing any additional devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected.
About this guide Audience This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server. Contents This guide contains the following parts: 1. 2. 3. 4. 5. 6. 7 Chapter 1: Product Introduction This chapter describes the general features of the server, including sections on front panel and rear panel specifications.
Conventions To ensure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
xii
This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specifications.
1.1 System package contents Check your system package for the following items.
1.2 Serial number label Before requesting support from the ASUS Technical Support team, you must take note of the product’s serial number containing 14 characters such as xxS0xxxxxxxxxx. See the figure below. With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems.
1.3 System specifications The ASUS RS920-E7/RS8 and RS926-E7/RS8 are servers featuring the ASUS Z9PX-Q32 Series server board.The server supports the Intel® Xeon® E5-4600 processor family, plus other latest technologies through the chipsets onboard. Model Name Processor Support Core Logic Memory Total Slots Capacity RS926-E7/RS8 RS920-E7/RS8 4 x LGA 2011 socket Intel® Xeon® Processor E5-4600 Product Family (up to 130W) Intel® QuickPath Interconnect (QPI) 6.4/7.2/8.
Model Name Networking LAN Infiniband Graphic VGA Auxiliary Storage Device Bay Onboard I/O RS926-E7/RS8 RS920-E7/RS8 Quad Port Intel Ethernet Controller i350 + 1 Management port Single port Mellanox N/A ConnectX-3 FDR InfiniteBand with QSFP Interface Aspeed AST2300 16MB 1 x Slim-type Optical Device Bay 1 x Internal Serial Port 5 x RJ-45 ports (1 port for remote management) 6 x USB 2.0 ports (2 x Front panel; 4 x Rear panel) 2 x USB 3.
1.4 Front panel features The barebone server displays a simple yet stylish front panel with easily accessible features. The power and reset buttons, LED indicators, optical drive, and two USB ports are located on the front panel. Refer to section 1.7.1 Front panel LEDs for the LED descriptions. Reset button Message LED LAN1 LED LAN2 LED HDD Access LED USB ports ODD dummy cover HDD 1 HDD 5 1.
1.6 Internal features The barebone server includes the basic components as shown. 1. 8 8 8 1 2. 3. 4. 5. 2 6. 7. 8. 3 Redundant Power supply and power fan (hidden) ASUS Z9PX-Q32 Server Board System fans SATA/SAS backplane (hidden) Hot-swap HDD tray 1–8 (SAS and SATA) Slim-type optical drive bay Front I/O board (hidden) PCI-E Expansion Boards (hidden) 4 5 6 7 The barebone server does not include a floppy disk drive.
1.7 LED information 1.7.1 Front panel LEDs LAN1 LED LAN2 LED HDD Access LED LED Power LED Location LED Message LED LAN LEDs HDD Access LED 1-8 Icon Message LED Location LED Power LED Display Description status ON System power ON OFF Normal status ON Location switch is pressed (Press the location switch again to turn off) OFF System is normal; no incoming event ON 1. Without ASMB6-iKVM installed: CPU over-heated 2.
1.7.
1.7.3 HDD status LED HDD Activity LED (Green) HDD Status LED (Red) SATAII/SAS HDD LED Description OFF HDD Activity LED (Green) ON HDD Status LED (Red) 1-10 HDD not present HDD present, no activity Blinking 1. Read/write data from/into the SATAII/SAS HDD 2. Locating (blinking with the HDD status LED) OFF HDD not present ON HDD has failed and should be swapped immediately Blinking 1. RAID rebuilding 2.
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
2.1 Chassis cover Removing the rear cover 1. Locate and remove the side screws. 2. Loosen the two thumbscrews on the rear panel. Thumbscrews 3. 4. 5. Firmly hold the cover and slide it toward the rear panel for about half an inch until it is disengaged from the chassis. Lift the cover from the chassis. To recover the rear cover, reverse step 1 to 4. A protection film is pre-attached to the system cover before shipping.
2.2 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA2011 socket designed for the Intel® Xeon E5-4600 family processor. 2.2.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related.
2. Press the left load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. 3. Slightly lift the load lever in the direction of the arrow. 4. Press the right load lever with your thumb (C), then move it to the right (D) until it is released from the retention tab. Lift the load lever in the direction of the arrow (E).
5. Push the left load lever (F) to lift the load plate (G). F G 6. Position the CPU over the socket, ensuring that the triangle mark is on the top‑right corner of the socket. Triangle mark The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! 7. Remove the PnP cap (H) from the CPU socket and close the load plate (I).
8. Push down the right load lever (J), ensuring that the edge of the load plate is fixed by the lever (K). K J 9. Insert the right load lever under the retention tab. 10. Push down the left load lever (L), and then insert the lever under the retention tab (M).
11. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer. Some heatsinks come with preapplied thermal paste. If so, skip this step. The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off immediately, and seek professional medical help.
2.2.2 Installing the CPU heatsink and airduct To install the CPU heatsink: 1. Place the heatsink on top of the installed CPU, ensuring that the four fasteners match the holes on the motherboard. 2. Twist each of the four screws with a Philips (cross) screwdriver just enough to attach the heatsink to the motherboard. When the four screws are attached, tighten them one by one to completely secure the heatsink. A B B A Tighten the four heatsink screws in a diagonal sequence.
2.3 System memory 2.3.1 Overview The motherboard comes with thirty-two (32) Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets.
2.3.2 Memory Configurations You may install 1GB/2GB/4GB/8GB/16GB/32GB Registerd or 1GB/2GB/4GB/8GB Unbuffered with ECC/Non-ECC DDR3 DIMMs into the DIMM sockets using the memory configurations in this section.
2.3.3 1. 2. Installing a DIMM on a single clip DIMM socket Unlock a DIMM socket by pressing the retaining clip outward. DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket. 1 2 DIMM slot key Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM. 3.
2.3.4 Installing a DIMM on a double-clip DIMM socket Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. 2. Press the retaining clips outward to unlock a DIMM socket. 2 DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket. 1 1 Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction.
2.4 Hard disk drives The system supports eight hot-swap SATAII/SAS hard disk drives. The hard disk drive installed on the drive tray connects to the motherboard SATAII/SAS ports via the SATAII/SAS backplane. To install a hot-swap SATAII/SAS HDD: 1. Release a drive tray by pushing the spring lock to the right, then pulling the tray lever outward. The drive tray ejects slightly after you pull out the lever. 2. Firmly hold the tray lever and pull the drive tray out of the bay. 3.
5. Carefully insert the drive tray and push it all the way to the depth of the bay until just a small fraction of the tray edge protrudes. When installed, the SATAII/SAS connector on the drive connects to the SATAII/ SAS interface on the backplane. 6. 7. 2-14 Push the tray lever until it clicks, and secures the drive tray in place. The drive tray is correctly placed when its front edge aligns with the bay edge. Repeat steps 1 to 6 if you wish to install a second SATAII/SAS drive.
2.5 Expansion slot 2.5.1 Installing an expansion card to the riser card bracket The barebone server comes with a riser card bracket. You need to remove the bracket if you want to install PCI Express x16 expansion cards. To install a PCI Express x16 card 1. Loosen the screws of the riser card bracket. 2. Place the riser card bracket on a flat and stable surface, and then remove the screw from the slot bay. 3. Loosen the screw of rear end bracket and remove it. PCI Express x16 slot 4.
2-16 5. Firmly hold the bracket, and then press it down to the slot of the motherboard. 6. Secure the screw in front of the GPU computing module bracket.
2.5.2 Configuring an expansion card After installing the expansion card, configure the it by adjusting the software settings. 1. 2. 3. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for information on BIOS setup. Assign an IRQ to the card. Refer to the tables on the next page. Install the software drivers for the expansion card.
2.6 Cable connections • The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you will remove pre‑installed components to install additional devices. • Refer to Chapter 4 for detailed information on the connectors. 4 8 8 10 9 11 7 6 5 1 2 3 3 3 3 3 Pre-connected system cables 1. 2. 3.
2.7 SATAII/SAS backplane cabling Connects a 8-pin plug from power supply Connects to the Intel® C602 SATA or PIKE SATA / SAS connectors on the motherboard Onboard SGPIO1 connects to BP the SGPIO1 connector to support Intel® RST SGPIO function PSGPIO1/2: Connects to BP the SGPIO2/3 connector to support Intel® SCU RAID, LSI RAIO SGPIO function.
2.8 Removable/optional components You may need to remove previously installed system components when installing or removing system devices. Or you may need to install the optional components into the system. This section tells how to remove/install the following components: 1. System fans 3. ASUS PIKE RAID card (optional) 2. Redundant power supply units Ensure that the system is turned off before removing any components. 2.8.1 System fans To uninstall the system fans 2-20 1.
3. 4. Lift the fan, and then set aside. Repeat steps 1 to 3 to uninstall the other system fans. To reinstall the system fans 1. 2. Insert the fan into the fan cage. The airflow directional arrow on the fan side should point towards the system rear panel. Insert the system fan cable into the cable holder, then connect the cable to the fan connector on the motherboard. 2.8.2 Redundant power supply units To remove the power supply unit (PSU) 1. Lift up the PSU lever.
2. Hold the PSU lever and press the PSU latch. 3. Firmly pull the PSU out of the system chassis. To install a second PSU 2-22 1. Insert the PSU into the empty PSU bay. 2. Hold the PSU lever and press the PSU latch. Firmly insert the PSU into the server chassis.
• If you install two power supply units in the system, you can switch the working behavior of the two PSUs between 1+1 jumper mode and 2+0 jumper mode. 1+1 jumper mode: If the total power consumption of the system is less than 1400W, the system can be booted using one PSU and the PSU hotswap feature is supported.
2. Remove the four screws that secure the outer heatsink on the front of the SAS RAID card. DO NOT remove the inner heatsink from the SAS RAID card. 2-24 3. Remove the data cables connected to the SATA connectors on the motherboard. 4. Locate the PIKE RAID card slot on the motherboard, then remove the screw beside the PIKE slot.
5. Align the golden fingers of the RAID card with the PIKE RAID card slot then insert the RAID card into the PIKE RAID card slot. Ensure that it is completely seated in place, then secure the PIKE card with the screw you removed earlier. 6. Connect the data cables in numerical order, from SATA1-5 to the SAS connectors labeled PSAS1-4 (Blue) and 5 (Black) on the motherboard.
2-26 Chapter 2: Hardware setup
This chapter describes how to install the optional components and devices into the barebone server.
3.1 Installing friction rail kit items Your friction rail kit package contains: • One pair of rack rails • 4 latch screws, 4 rail screws and 4 rail washers • One pair of fixing latches Rail Washers Rail screws Latch screws Front end 3.1.1 Fixing latches Rack rails Rear end Attaching the fixing latches to the server Refer to the figures below for the locations to attach the two fixing latches to the two sides of the server with four screws.
1. 2. Select a 1U space on the rack where you want to install the rack rail. A 1U space consists of three square mounting holes with two thin lips on the top and the bottom, as shown in the right figure. Adjust the rack rail to fit the depth of the rack. 3. From inside the rack, place the rear rail hook on the bottom thin lip of the rear mounting hole, and then place the front rail hook on the bottom thin lip of the front mounting hole, as shown in the right figure. 4.
6. When mounting the server to the rack, ensure to include the side knots on the two sides of the server in the rack rail holders, as shown in the right figure. Do not install the rail kit in the following situation: DO NOT place the rail hook on a thick lip of the mounting hole. 3-4 DO NOT install the rail to the outer side of the server rack.
3.1.2 Mounting the server to the rack To mount the server to the rack: 1. 2. Align the server rails with the rack rails, then push the server all the way to the depth of the rack. Drive two screws on both mounting ears to secure the server in place. To uninstall the server from the rack: 1. 2. Remove the screws secured on the mounting ears. Hold the mounting ears, then pull the server from the rack. Remember to press the latches on both sides to release the server from the rack.
3-6 Chapter 3: Installation options
This chapter includes the motherboard layout, and brief descriptions of the jumpers and internal connectors.
4.1 Motherboard layout Layout contents Jumpers 4-2 Page 1. Clear RTC RAM (CLRTC1) 4-4 2. VGA controller setting (3-pin VGA_SW1) 4-5 3. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) 4-5 4. LAN controller setting (3-pin LAN_SW1) 4-6 5. ME firmware force recovery setting (3-pin ME_RCVR1) 4-6 6. DIMM thermal trip Setting (3-pin DIMMTRIP1) 4-7 7.
Internal connectors Page 1. Serial ATA 6.0/3.0 Gb/s connectors (7-pin SATA6G_1-2 [black]) (7-pin SATA3G_3-6 [black]) 4-8 2. ISAS connectors 4-9 3. PSAS connectors 4-9 4. USB connectors (10-1 pin USB56, A-Type USB10) 4-10 5. Hard disk activity LED connector (4-pin HDLED1) 4-10 6. CPU and front fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–5) 4-11 7. Serial General Purpose Input/Output connectors (6-1 pin SGPIO1, 8-1 pin PSGPIO 1/2 and ISGPIO1) 4-12 8.
4.2 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. 2. 3. 4. Turn OFF the computer and unplug the power cord. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. 3. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) This jumper allows you to select the PCH SATA RAID mode to use LSI MegaRAID software or Intel® Rapid Storage Technology enterprise 3.0 RAID.
4. 5. 4-6 LAN controller setting (3-pin LAN_SW1) These jumpers allow you to enable or disable the onboard Intel® i350 Gigabit LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature. ME firmware force recovery setting (3-pin ME_RCVR1) This jumper allows you to force Intel Management Engine (ME) boot from recovery mode when ME become corrupted.
6. 7. DIMM thermal trip Setting (3-pin DIMMTRIP1) This jumper allows you to enable(default) or disable DIMM thermal trip. BMC Setting (3-pin BMC_SW1) This jumper allows you to enable(default) or disable the Baseboard Management Controller.
4.3 1. Internal connectors Serial ATA 6.0/3.0 Gb/s connectors (7-pin SATA6G_1-2 [black]) (7-pin SATA3G_3-6 [black]) Supported by the Intel® C602 Chipset, these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6Gb/s of data transfer rate. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 10, or RAID 5 configuration. The actual data transfer rate depends on the speed of Serial ATA hard disks installed.
2. ISAS connectors Supported by the Intel® C602 Chipset. ISAS 1-4 connectors can connect to serial ATA 3Gb/s hard disk drives. The actual data transfer rate depends on the speed of SATA hard disks installed. 3. PSAS connectors (PIKE required) SAS connector - PSAS connectors are for the SAS signal cables for SAS hard disk drives that allows up to 6Gb/s of data transfer rate. If you installed SAS hard disk drives, you can create a RAID 0, RAID 1, RAID 10, or RAID 5 configuration.
4. 5. 4-10 USB connectors (10-1 pin USB56, A-Type USB10) These connectors are for USB 2.0 ports. Connect the USB module cable to connector USB56, then install the module to a slot opening at the back of the system chassis. These USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card.
6. CPU and front fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–5) The fan connectors support cooling fans. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire of each cable matches the ground pin of the connector. • DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components.
7. Serial General Purpose Input/Output connectors (6-1 pin SGPIO1, 8-1 pin PSGPIO 1/2 and ISGPIO1) The SGPIO 1 connectors are used for the Intel Rapid Storage Technology Enterprise SGPIO interface that controls the LED pattern generation, device information and general purpose data. The PSGPIO 1/2 connectors are used for PIKE card. The ISGPIO 1 connector is for SATA connectors—ISAS connectors.
8. 9. Serial port connector (10-1 pin COM1) These connectors are for the serial (COM) ports. Connect the serial port module cable to one of these connectors, then install the module to a slot opening at the back of the system chassis. TPM connector (20-1 pin TPM1) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data.
10. Power Supply SMBus connector (6-1 pin PSUSMB1) This connector allows you to connect SMBus (System Management Bus) to the power supply unit to read PSU information. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface.
11. EATX power connectors (24-pin ATXPWR1, 8-pin ATX12V1) These connectors are for an EATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • DO NOT forget to connect the 24+8-pin power plugs; otherwise, the system will not boot up. • Use of a PSU with a higher power output is recommended when configuring a system with more power-consuming devices.
12. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1. 2. 3. 4. 5. 6. 4-16 System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
13. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 1. Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. 2. LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel. 3.
4.4 1. 2. Internal LEDs Standby Power LED (SB_PWR1) The motherboard comes with a standby power LED. The green LED lights up to indicate the system AC power cable plug or not. This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard LED. DIMM warning LED (ERR_DIMM) The DIMM warning LEDs light up to indicate an impending failure of the corresponding DIMMs.
3. 4. CPU warning LED (ERR_CPU1/2/3/4) The CPU warning LEDs light up to indicate an impending failure of the corresponding CPU. CATTERR LED (CATTERR_LED1) The CATTERR LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate.
5. 6. 4-20 Baseboard Management Controller LED (BMC_LED1) The BMC LED works with the ASUS ASMB6 management device and indicates its initiation status. When the PSU is plugged and the system is OFF, ASUS ASMB6 management device starts system initiation for about one (1) minute. The BMC LED blinks after system initiation finishes. • The heartbeat LED functions only when you install the ASUS ASMB6.
Q-Code table Action Normal boot PHASE Security Phase POST CODE 01 TYPE Progress DESCRIPTION First post code(POWER_ON_POST_CODE) 03 Progress Set cache as ram for PEI phase(CACHE_ENABLED_POST_CODE) 02 06 PEI(Pre-EFI initialization) phase 04 10 15 19 78~00 A1 A3 A7 A8 A9 AA AB AC AD AE AF 2F B0 B1 AF B4 B2 B3 B5 B6 B7 B8 B9 BA BB BC BF 5A 31 32 34 36 4F Progress Progress Progress Progress Progress Progress Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progres
Action Normal boot PHASE POST CODE DXE(Driver 60 Execution 61 Environment) phase 62 63 68 69 6A 70 71 72 78 BDS(Boot Device Selection) phase 79 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D b2 b3 b4 b6 b7 A0 A1 A2 A3 A8 A9 AB AD Operating system phase AE 17 18 19 20 21 22 23 24 25 4-22 TYPE Progress DESCRIPTION DXE Core Started Progress SB run-time init.
Chapter 5 BIOS setup This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
5.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. 3. ASUS CrashFree BIOS 3 (Recovers the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted.) ASUS EZ Flash 2 (Updates the BIOS using a USB flash disk.) BUPDATER utility (Updates the BIOS in DOS mode using a bootable USB flash disk drive.) Refer to the corresponding sections for details on these utilities.
5.1.2 ASUS EZ Flash 2 Utility The ASUS EZ Flash 2 Utility feature allows you to update the BIOS without having to use a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash 2 Utility 1. 2. Insert the USB flash disk that contains the latest BIOS file into the USB port. Enter the BIOS setup program. Go to the Tool menu then select ASUS EZ Flash 2 Utility. Press .
• This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press and select Yes to load the BIOS default settings. 5.1.3 BUPDATER utility The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
4. The utility verifies the file, then starts updating the BIOS file. ASUSTek BIOS Update for DOS V1.30 (11/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: Z9PE-D16 VER: 0203 DATE: 08/24/2011 Update ROM BOARD: Z9PE-D16 VER: 0206 DATE: 09/30/2011 PATH: WARNING! Do not turn off power during flash BIOS Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the DOS prompt after the BIOS update process is completed.
5.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 5.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
5.2.1 BIOS menu screen Menu items Main Menu bar Configuration fields General help Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.
5.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Event Logs, Advanced, Monitor, Boot, Tool, and Exit) on the menu bar have their respective menu items. 5.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item then press . 5.2.
5.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time, language, and security settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.
5.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Socket 1 CPU Information Enter to view socket specific CPU Information. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Enter to view socket soecific CPU Information. Socket 1 CPU Information Genuine Intel(R) CPU @ 2.
Adjacent Cache Line Prefetch [Enabled] This Item allows you to turn on/off prefetching of adjacent cache lines. Configuration options: [Disabled] [Enabled] DCU Streamer Prefetcher [Enabled] This Item allows you to enable or disable prefetcher of next L1 data line. Configuration options: [Disabled] [Enabled] DCU IP Prefetcher [Enabled] This Item allows you to enable or disable prefetch of next L1 line based upon sequential load history.
5.4.2 CPU Power Management Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced This item allows you to enabled power management features.
Package C State limit [C6] This item allows you to set package C State limit. Configuration options: [C0] [C2] [C6] [No Limit] Energy Performance [Balanced Performance] This item allows you to optimize between performance and power savings. Windows 2008 and later operating systems override this value according to this power plan.
5.4.3 Chipset Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced QPI Configuration Memory Configuration CPU II0 Bridge Configuration PCH Configuration Intel(R) VT for Directed I/O Configuration QPI Configuration Page QPI Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Memory Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Patrol Scrub [Disabled] Allows you to enable/disable Patrol Scrub. Configuration options: [Disabled] [Enabled] Demand Scrub [Enabled] Allows you to enable/disable demand scrubing feature. Configuration options: [Enabled] [Disabled] Data Scrambling [Enabled] Allows you to enable/disable data scrambling. Configuration options: [Enabled] [Disabled] Device Tagging [Disabled] Allows you to enable/disable device tagging.
DIMM Information Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
PCH Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Name Stepping Support for PCH Compatibility Patsburg 06 (C1 Stepping) Revision ID(CRID) functionality. SB Chipset Configuration PCH Compatibility RID [Disabled] Deep Sx SCU devices Onboard SATA RAID Oprom [Disabled] [Enabled] [Enabled] High Precision Event Timer Configuration High Precision Timer [Enabled] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
Intel(R) VT for Directed I/O Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel(R) VT-d [Disabled] Allows you to enable or disable BIOS ACPI Auto Configuration. Intel(R) VT-d [Disabled] Allows you to enable or disable Intel® VT-d. Configuration options: [Enabled] [Disabled] The following item appears only when you set Intel(R) VT-d to [Enabled]. Coherency Support [Disabled] Allows you to enable/disable VT-d Engine Coherency support.
SATA Mode [AHCI Mode] Allows you to set the SATA configuration. Configuration options: [Disabled] [IDE Mode] [AHCI Mode] [RAID Mode] • If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, set this item to [IDE Mode]. • If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), keep the default setting [AHCI Mode].
5.4.5 PCH SCU Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Device1 Device2 Device3 Device4 Intel Intel Intel Intel ISR10a ISR10a ISR10a ISR10a Patsburg B/D sku only →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. 5.4.
VGA Palette Snoop [Disabled] Allows you to enable or disable VGA pallette registers snooping. Configuration options: [Disabled] [Enabled] PERR# Generation [Disabled] Allows you to enable or disable PCI device to generate PERR#. Configuration options: [Disabled] [Enabled] SERR# Generation [Disabled] Allows you to enable or disable PCI device to generate SERR#. Configuration options: [Disabled] [Enabled] Load RT32 Image [Enabled] Allows you to enable or disable RT32 Image Loading.
PCIE Slot Option Rom Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Legacy OpROM Support Launch Storage 0pROM [Enabled] PCIE1 Option Rom PCIE2 Option Rom PCIE3 Option Rom PIKE Option Rom [Enabled] [Enabled] [Enabled] [Enabled] Allows you to enable or disable boot option for legacy mass storage device with option ROM. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
5.4.7 Onboard LAN Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PXE/iSCSI.
Intel LAN4 Enable [Enabled] Allows you to enable or disable Intel® LAN4 function.
5.4.8 USB Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced USB Configuration USB Devices: 3Drivers, 1Keyboard, 1 Mouse, 3 Hubs Legacy USB Support USB3.0 Support XHCI Hand-off EHCI Hand-off [Enabled] [Enabled] [Enabled] [Disabled] USB hardware delays and time-outs USB transfer time-out Device reset time-out [20 sec] [20 sec] USB Ports Configuration Enabled Legacy USB support.
USB Ports Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced EHCI Controller 1 EHCI Controller 2 [Enabled] [Enabled] USB USB USB USB USB USB USB [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Port1 Port2 Port3 Port4 Port5 Port6 Port10 Enable/disable USB 2.0 (EHCI) Support. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
5.4.10 ACPI Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced ACPI Settings Enable ACPI Auto Configuration [Disabled] Enabled Hibernation ACPI Sleep State Lock Legacy Resources Allows you to enable or disable BIOS ACPI Auto Configuration. [Enabled] [S1 (CPU Stop Clock)] [Disabled] Enable ACPI Auto Configuration [Disabled] Allows you to enable or disable BIOS ACPI Auto Configuration.
5.4.11 WHEA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced WHEA Support [Enabled] Enable or disable Windows Hardware Error Architecture. WHEA Support [Enabled] Allows you to enable or disable the Windows Hardware Error Architecture support. Configuration options: [Disabled] [Enabled] 5.4.12 APM setting Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
5.4.13 Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced COM1 Console Redirection Console Redirection Settings [Disabled] COM2 Console Redirection Console Redirection Settings [Enabled] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Console Redirection Settings Consloe Redirection Enable or Disable.
Data Bits [8] Configuration options: [7] [8] Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [None] None [Even] parity bit is 0 if the num of 1’s in the data bits is even [Odd] parity bit is 0 if num of 1’s in the data bits is odd [Mark] parity bit is always 1 [Space] parity bit is always 0 Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.
Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Allows you to enable or disable the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port.
5.4.14 ME Subsystem Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel ME Subsystem Configuration ME BIOS Interface Version 1.2 ME Version ME FW Status Value : ME FW State : ME FW Operation State: ME FW Error Code: ME Ext FW Status value: BIOS Booting Mode: Cores Disabled: ME FW SKU Information: ME Subsystem Help. 2.1.5.
Serial Port [Enabled] Allows you to enable or disable the serial port. Configuration options: [Disabled] [Enabled] Device Mode [Standard Serial Port Mode] Allows you to change the serial port mode. Configuration options: [Standard Serial Port Mode] ASmedia USB 3.0 Controller [Enabled] [Enabled] [Disabled] Enables the USB 3.0 controller. Disables the controller. ASmedia USB 3.0 Battery Charging Support [Disabled] [Enabled] [Disabled] 5.4.16 Enables Asmedia USB 3.
5.5 Server Mgmt menu The Server Mgmt menu displays the server mgmt status, and allows you to change the settings. The Server Mgmt menu appears only when you install ASMB card on the motherboard. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BMC Firmware: x.
5.5.1 System Event Log Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt Enabling/Disabling Options SEL Components [Disabled] Erasing Settings Erase SEL When SEL is Full [No] [Do Nothing] Note: All values changed here do not take effect until computer is restarted. Change this to enable or disable all features of system Event Logging during boot. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
5.5.2 BMC network configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt BMC network configuration DM_LAN1 DM_LAN1 IP Address in BMC: DM_LAN1 Subnet Mask in BMC: DM_LAN1 Gateway Address in BMC : DM_LAN1 MAC Address in BMC: DM_LAN1 Address Source in BMC: Configuration Address source 192.168.001.001 255.255.255.000 000.000.000.000 00.CE.01.87.72.
5.6 Event Logs menu The Event Logs allows you to change or view the event log settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Press to change the Smbios Event Log configuration. Change Smbios Event Log Settings View Smbios Event Log View System Event Log →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
Erasing Settings Erase Event Log [No] Choose options for erasing Smbios Event Log. Erasing is done prior to any logging activation during reset. Configuration options: [No] [Yes, Next reset] [Yes, Every reset] When Log is Full [Do Nothing] Allows you to choose options for reactions to a full Smbios Event Log. Configuration options: [Do Nothing] [Erase Immediately] Smbios Event Log Standard Settings Log System Boot Event [Disabled] Allows you to choose options to enable/disable logging of System boot event.
5.7 Boot menu The Boot menu items allow you to change the system boot options. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Boot Configuration Setup Prompt Timeout Bootup NumLock State 1 [On] Full Screen Logo [Enabled] CSM16 Module Version 07.
Interrupt 19 Capture [Enabled] Allows Option ROMs to trap interrupt 19. Configuration options: [Disabled] [Enabled] Boot Device Seeking [Endless PXE] [Endless PXE] Continuous seek remote boot image until boot image found or user abort (press Ctrl+Alt+Del). [Normal] Seek remote boot image once then stop. UEFI Boot [Disabled] Allows you to enable or disable UEFI Boot.
5.8 Monitor menu The Monitor menu displays the system temperature/power status, and allows you to change the fan settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
+VTT_CPU Voltage, VCORE1/2 Voltage, +VDDQ_AB_CPU1 Voltage, +VDDQ_CD_CPU1 Voltage, +VDDQ_EF_CPU2 Voltage, +VDDQ_GH_CPU2 Voltage, +5VSB Voltage, +5V Voltage, +12V Voltage, +3.3V Voltage, VBAT Voltage, +3.3VSB Voltage The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators. FAN Speed Control [Generic Mode] Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation.
Administrator Password If you have set an administrator password, we recommend that you enter the administrator password for accessing the system. Otherwise, you might be able to see or change only selected fields in the BIOS setup program. To set an administrator password: 1. 2. 3. Select the Administrator Password item and press . From the Create New Password box, key in a password, then press . Confirm the password when prompted. To change an administrator password: 1. 2. 3. 4.
To clear the user password, follow the same steps as in changing a user password, but press when prompted to create/confirm the password. After you clear the password, the User Password item on top of the screen shows Not Installed. 5.10 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Boot Override These items displays the available devices. The device items that appears on the screen depends on the number of devices installed in the system. Click an item to start booting from the selected device. Launch EFI Shell from filesystem device Attempts to launch EFI Shell application (shellx64.efi) from one of the available filesystem devices. Discard Changes & Exit This option allows you to exit the Setup program without saving your changes.
5-48 Chapter 5: BIOS setup
This chapter provides instructions for setting up, creating and configuring RAID sets using the available utilities.
6.1 Setting up RAID The motherboard supports the following SATA RAID solutions: • • LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Technology enterprise SCU / SATA Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). 6.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks.
6.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. 2. 3. Install the SATA hard disks into the drive bays following the instructions in the system user guide. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard.
6.2 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility: 1. 2. Turn on the system after installing all the SATA hard disk drives.
Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow keys to select the drives you want to include in the RAID set, and then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5. Press again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
8. 9. Select Units from the Virtual Drive sub-menu, and then press . Select the units for virtual drive size from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
12. When finished setting the selected virtual drive configuration, select Accept from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
Using New Configuration When a RAID set already exists, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option 1. From the Management Menu, select Configure > New Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
6.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
6.2.3 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command 1. From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
3. Press to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.
Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. Select Initialize from the pop-up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
6.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. After selecting the drive to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
6.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command 1.
3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
Using the Objects command To check data consistency using the Objects command 1. 2. 3. 4. 5. 6-20 From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press . Select Check Consistency from the pop-up menu, and then press . When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue.
6.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
6.2.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section 6.2.1 Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
6.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache 1. 2.
6.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility The Intel® Rapid Storage Technology enterprise SCU / SATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You can create RAID mode by use of onboard AHCI SATA ports. To use onboard SATA ports: 1. 2. 3. 4. Install all the Serial ATA hard disk drives. Turning on the system.
To enter the Intel® Rapid Storage Technology enterprise SCU option ROM / SATA option ROM utility: 1. Install all the Serial ATA hard disk drives. 3. During POST, press to display the utility main menu. 2. Turn on the system. Intel(R) Rapid Storage Technology enterprise - SCU Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4.
6.3.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select 1. Create RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology enterprise - SCU Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8.
2. 3. 4. Enter a name for the recovery set and press . When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press . When the Disks item is selected, press to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3300656SS ST3300656SS ST3300656SS ST3300656SS Serial # HWAS0000991753TR 37VN00009846RAJ1 397600009846UEDY GWC50000991756G6 Size 279.
6.3.3 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology enterprise - SCU Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
6.3.4 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk.
6.3.5 Exiting the Intel® Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 4. Exit, and then press . The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press to exit or press to return to the utility main menu. 6.3.6 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology enterprise - SCU Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4.
6.3.7 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Rapid Storage Technology. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. 2. 3. 4. 5. Reboot the system and press to enter the BIOS setup utility during POST. Go to the Boot menu and select the boot option priority.
6.4 Intel® Rapid Storage Technology enterprise Utility (Windows) The Intel® Rapid Storage Technology enterprise utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. To enter the Intel® Rapid Storage Technology enterprise SCU option ROM utility under Windows operating system: 1. 2. Turn on the system to windows desktop.
6.4.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select Create Volume and select volume type. 2. Then click Next. 3. Enter a name for the RAID set, then select the array disks. 5. Then click Next. 4. Select Volume Size tab, you can drag the bar to decide the volume size. • If you hard disk with existing data and you don’t want to keep data from one of the selected disks, choose NO in next column (If displayed).
6. Confirm volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can contuine using other applications during this time. When display Volume Ceation Complete message, you can click OK to finish. You still need to partition your new volume using Windows Disk Management before adding any data.
6.4.2 Change Volume Type When you are finished to create a RAID set, you can view or change related items in the Volume Properties field. According to the following steps to change the type in Volume Properties: 1. Click the SAS array items you want to change in Volumes field. 2 From the Volume Properties field, select Type:RAID 1 Change type. 3. You can change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 4.
6.4.3 Delete volume Take caution when deleting a volume. You will lose all data on the hard disk drives.Back up data before continuing. To delete a volume: 6-38 1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes field you want to delete. 2. Then select Delete volume in Volume Properties field. The following screen appears. 3. Click Yes to delete the volume and return to the utility main menu, or click No to return to the main menu.
6.4.4 Preferences System Preferences Allow you set to show the notification area icon and show system information, warning, or errors here.
6-40 Chapter 6: RAID configuration
This chapter provides instructions for installing the necessary drivers for different system components.
7.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 7.1.1 Creating a RAID driver disk The system does not include a floppy drive. You have to use a USB floppy drive when creating a SATA RAID driver disk.
LSI 2008 SAS2 Driver LSI 2008 SAS2 Driver Windows XP 32 bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL 4 UP7 32 bit RHEL 4 UP7 64 bit RHEL 4 UP8 32 bit RHEL 4 UP8 64 bit Back Exit 6. 7. 8. Locate the RAID driver and place a blank, high-density floppy disk to the floppy disk drive. Press .
7.1.2 Installing the RAID controller driver During Windows® Server 2008 OS installation To install the RAID controller driver when installing Windows® Server 2008 OS 1. 2. 3. 7-4 Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen instructions to start installing Windows Server 2008. When prompted to choose a type of installation, click Custom (advanced). Click Load Driver.
4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller driver. If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive. Click Browse to continue. 5. Locate the driver in the corresponding folder of the Support DVD, and then click OK to continue. 6. Select the RAID controller driver you need from the list and click Next. 7.
Red Hat® Enterprise Linux OS 5.6 To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS: 1. 2. Boot the system from the Red Hat® OS installation CD. At the boot:, type linux dd noprobe=ata1 noprobe=ata2..., then press . The number of ata varies with the hard disk drive number you have when building a RAID set.
5. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes 6. No Follow the onscreen instructions to finish the OS installation. 7. When the installation is completed, DO NOT click Reboot. Press + + to switch to the command-line interface from graphic user interface. 8. Type the following commands when using a Legacy floppy.
Red Hat® Enterprise Linux OS 6.1 To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS: 1. Boot the system from the Red Hat® OS installation CD. 3. While booting from DVD, press to give the third party driver. Enter the following command at the boot: Linux dd blacklist=isci blacklist=ahci nodmraid, then press . 2. 7-8 Press to edit options.
4. Select Yes using the key when asked if you have the driver disk, then press . Main Menu Do you have a driver disk? Yes No 5 . You have multiple devices which could serve as source for a driver disk. Choose one you like to use and select OK, then press . Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk.
6. Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press . Insert Driver Disk Insert your driver disk into /dev/sdb and press “OK” to continue. OK Back The drivers for the RAID card are installed to the system. 7. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes 8. 7-10 No Follow the onscreen instructions to finish the OS installation.
Preparing the Linux Driver Ensure that there is another computer with a Linux-based OS to create the RAID driver. When creating the RAID driver, you may refer to the examples below which uses a 64bit SUSE Linux system to create a 64bit RAID driver for SUSE11 sp1. 1. 2. 3. Copy the image file into the Linux system. Example: megasr-15.00.0120.2012-1-sles11-ga-x86_64.img Create a folder.
Installing SUSE 11 Linux OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS: 1. Boot the system from the SUSE OS installation CD. 3. Press , then select Yes from the menu. Press . 2. 7-12 Use the arrow keys to select Installation from the Boot Options menu.
4. Use the USB drive to provide the third-party driver during the OS installation. Type the command brokenmodules=ahci in Boot Options field, and press . 5. When below screen appears, select the USB floppy disk drive (sda) as the driver update medium. Select OK, then press .
6. The drivers for the RAID controller are installed to the system as shown below. Please choose the Driver Update medium. sda: USB Floppy sr0: CD-ROM, ASUS DRW-1612BLT sdb: Disk, LSI MEGA RAID sd3: Disk, LSI MEGA RAID Console other device OK 7. 7-14 Back Select Back and follow the onscreen instructions to finish the installation.
7.2 Intel® chipset device software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
7-16 5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. Toggle Yes, I want to restart the computer npw and click Finish to complete the setup process.
7.3 Intel@ Network Connections Software installation This section provides the instructions on how to install the Intel® Network Connections Software on the system. You need to manually install the Intel® Network Connections Software on a Windows® operating system. To install the Intel® Network Connections Software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
7-18 5. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 6. Toggle I accept the terms in the license agreement and click Next to continue. 7. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation.
8. Follow the screen instructions to complete installation. 9. When finished, press Finish to continue.
7.4 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Enter the user information and click Next to continue. 7. Select a setup type and click Next to continue.
7-22 8. Click Install to start driver installation. 9. When the installation completes, click Finish to restart your computer before using the program.
7.5 Intel® C600 Series Chipset SATA RAID Drivers This section provides the instructions on how to install the Intel® C600 Series Chipset Drivers on the system. You need to manually install the Intel® C600 Series Chipset SATA RAID (SATA mode) Drivers on a Windows operating system. To install the drivers: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
7.6 Microsoft .NET Framework 3.5 SP1 This section provides the instructions on how to install the Microsoft .NET Framework 3.5 SP1 software on the system. You need to manually install the Intel® Microsoft .NET Framework 3.5 SP1 software on a Windows operating system. To install the drivers: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
7.7 Intel® Rapid Storage Technology enterprise 3.0 installation This section provides the instructions on how to install the Intel® Rapid Storage Technology enterprise 3.0 on the system. You need to manually install the Intel® Rapid Storage Technology enterprise 3.0 utility on a Windows® operating system. To install the Intel® Rapid Storage Technology enterprise 3.0 utility: 1. 2. Restart the computer, and then log on with Administrator privileges.
7-26 5. Read the Warning message and click Next to continue. 6. Read the License Agreement and click Yes to continue. 7. Read the Readme File Information and click Next to continue.
8. After completing the installation, click Next to complete the setup process. 9. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program.
7.8 Intel® I350 Gigabit Adapters Driver installation This section provides the instructions on how to install Intel® I350 Gigabit Adapters Driver. To install the Intel® I350 Gigabit Adapters Driver on a Windows® OS: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
4. When the Intel® PRO Network Connections – InstallShield Wizard window appears, click Next to start the installation. 5. Click I accept the terms in the license agreement and then click Next to continue.
7-30 6. Select the programs you want to install and click Next to continue. 7. Click Install to start the installation.
8. The programs you select are being installed. 9. Click Finish to finish the installation.
7.9 Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 7.9.1 Running the support DVD Place the support DVD to the optical drive.
7.9.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 7.9.4 Make disk menu The Make disk menu contains items to create the Intel RAID driver disks. 7.9.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.
7-34 Chapter 7: Driver installation
ASUS contact information ASUSTeK COMPUTER INC. Address Telephone Fax E-mail Web site Technical Support Telephone Fax Online Support 15 Li-Te Road, Peitou, Taipei, Taiwan 11259 +886-2-2894-3447 +886-2-2890-7798 info@asus.com.tw http://www.asus.com +86-21-38429911 +86-21-58668722 ext: 9101 http://support.asus.com/techserv/techserv.aspx ASUSTeK COMPUTER INC.
ASUS contact information ASUS COMPUTER INTERNATIONAL (America) Address Fax Web site Technical Support Support fax General support Online support 800 Corporate Way, Fremont, CA 94539, USA +1-510-608-4555 http://usa.asus.com +1-812-284-0883 +1-812-282-2787 http://support.asus.com/techserv/techserv.aspx ASUS COMPUTER GmbH (Germany and Austria) Address Fax Web site Online contact Technical Support Telephone Support Fax Online support A-2 Harkort Str.