Information Sources .................................................. 2 IBM Netfinity 8500R Configurator ..........................108 Server Product Positioning ........................................ 4 IBM External Storage Expansion Unit Overview....117 Server Selection Guidance........................................ 6 IBM Netfinity EXP15 (3520-2RU) Configurator ......118 Server Selection Guidance ...................................... 7 IBM Netfinity EXP300 (35311RU) Configurator......
Information Sources Canada Audience Where to go How to get Server Paper Configurator Guide Customers www.ibm.com/pc/ca/netfinity/tech_library.html Select “Technical Info.” Business Partners www.ibm.com/pc/partner/ca Select “Sales Tools” and then “Marketing Essentials”. User ID and Password required. IBM Employees Marketing Essentials By Brand category --> IBM Netfinity or By Brand category --> PC Configurator Feedback www.ibm.com/pc/partner/ca/feedback.
United States Audience Where to go How to get Server Paper Configurator Guide Customers www.ibm.com/pc/us/netfinity/tech_library.html Select “Configuration Tools” Business Partners www.pc.ibm.com/partner/us/ Select Sales Tools, then Marketing Essentials, then IBM PC Server--> Paper Configurator. User ID and Password required. IBM Employees Marketing Essentials By Brand category --> IBM Netfinity or By Brand category --> PC Configurator Feedback www.ibm.com/pc/partner/us/feedback.
Server Product Positioning Increased Capacity: Application Memory Storage Slots Availability Features 85 70 0 76 0 55 00 56 51 0 50 45 35 30 10 0 00 40 00 M 00 00 00 71 0 M 0 M 00 R 10 0 0 20 0 00 R R 10 01 IBM Netfinity File and Print 4 1. Netfinity 1000 is not available in Canada or Latin America.
When in a competitive situation, this table suggests the appropriate IBM Netfinity server to bid against other vendors’ equipment.
Server Selection Guidance This graph represents general guidelines for selecting the appropriate server based on the number of users that can be supported in a particular application environment. This chart is for general guidance since each customer environment is unique and is unlikely to be precisely represented by any of the specific applications in the chart, but by using the chart, a reasonable approximation can be derived. External Storage Units are utilized when internal capacities are exceeded.
Server Selection Guidance DB Transaction Processing Select, Update and Delete; Does not include image or Decision Support File and Print Application is stored locally. (For server stored applications cut number of users in half). Lotus Notes 10% Power Users 40% Mail 50% Mail & DB Microsoft Exchange Server 5.5 100% Med Users 30 MB Mailbox SAP 3-Tier Distributed Ver 4.x Processing Sales and Distribution Application (Minimum of 16-20 Servers) SAP Central Version 4.
1. With a single Netfinity EXP200 storage unit installed in the standard NetBAY3 included with tower models. 2. With a Rack-to-Tower Conversion Kit installed. Procedure for Server Selection Guidance Chart File and Print numbers are Novell Netware-based with all others based on Microsoft Windows NT. Other Networking Operating System (NOS) results could vary. Extensive SAP sizings are available from IBM/SAP Competency Centers. Contact your IBM Marketing Representative for additional information.
SERVER SELECTION GUIDANCE Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 1000 (IDE) Configurator r ) ) il) so ) ) ns d) va ax es ax ax , Fa ) ar /M l/ A oc M M d / / r M a D td n t d d P D t M t S a o I t ( t S (T (S s, H ) en RD ,S s( r ive t Hz ys m ity al or R= Dr lle (M n t , S lo ge Ba B ) x) ( on ss o i k a a t r d e t a K il) r t s il) n a e ne n di .
Netfinity 1000 (IDE) Hard Disk Drive (HDD) Storage Total Internal Storage1 CD-ROM All Models 10.1 GB Standard Bay 2 20.2 GB 1 x 33L4958 Bay 3 30.3 GB 2 x 33L4958 This table does not represent all possible hard drive configurations. 1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted. Diskette Bay 5 Bay Form Height Factor Front Access Usage 1 133 mm (5.25”) HH yes IDE CDROM 2 133 mm (5.25”)1 HH yes open 3 89 mm (3.5”) SL yes open 6 89 mm (3.
Slot 1- PCI, 32-bit, Full Length Slot 2- PCI, 32-bit, Full Length Slot 3- PCI, 32-bit, Full Length Slot 4- ISA, Full Length Slot 5- ISA, Full Length Slot 6- ISA, Full Length AGP Netfinity 1000 (IDE) Power, Monitor & Accessories Part Number Description Power1 Uninterruptible Power Supply (UPS)2 94G3134 APC Smart-UPS 700 94G3135 APC Smart-UPS 1000 65464AN G54 Color Monitor 15” (348-mm, 13.7” Viewable Image Size), stealth black Monitors 65474AN G74 Color Monitor 17” (403-mm, 15.
Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements. Workgroup Intranet Server Part Number Description Quantity 8477-42Y Netfinity 1000 (IDE) Pentium III 600 MHz/512 KB L2, 64 MB ECC, Open, 40X, PCI/ ISA 1 01K1130 64 MB 100 MHz ECC SDRAM DIMM 33L4958 10.
IBM Netfinity 3000 Configurator or s) ) ) il) ) ss ) ID an d) va ax ax ce ax D, F ar ) RA /A d/M o l M M d , r / / M a n D a ) d P t (S t d r t M a z t o H t I t t d S H (T e (S ts, S Ul m en s) RD s( (M l, m ys riv a l, it y lo (m bp or d R= ua nt r, S ge Ba k D on (M te ss KB) )( i ee D a a t ( a e x t a il) a il) s p n a di D i .
Netfinity 3000 Memory Total Memory DIMM Socket Part Number 01K1133 All Models Except 15U 64 MB 64 MB DIMM Standard DIMM Socket 128 MB 1 x 01K1130 DIMM Socket 192 MB 1 x 01K1131 Memory Description 32 MB 100 MHz ECC SDRAM DIMM 256 MB 1 x 01K1131, 1 x 01K1130 320 MB 2 x 01K1131 384 MB 3 x 01K11311 512 MB 2 x 01K11321 01K1130 64 MB 100 MHz ECC SDRAM DIMM 01K1131 128 MB 100 MHz ECC SDRAM DIMM 768 MB (max) 3 x 01K11321 01K1132 256 MB 100 MHz ECC SDRAM RDIMM1 This table does not represe
a RAID controller and a dedicated removable media attachment to the onboard controller is required, an optional, terminated, 16-bit cable is available (Netfinity TwoDrop Internal SCSI Cable P/N 36L9636). This is not an Ultra2 cable; therefore attached devices will operate as Ultra or slower devices. If connecting narrow devices to this cable, additional 68-pin to 50-pin converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.
Netfinity 3000 Tape Options Part Number Description Bays SCSI Supported Interface (bit) Form Factor Termination 68/50-pin Ext. Tape Included Converter Enclosures1 Incl. 01K1282 12/24GB DDS/3 4-mm Internal Tape Drive 2 8 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 Y 3510020 00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive 2 16 Ultra2 LVD 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 N 3510020 01K1319 10/20 GB NS Internal SCSI Tape Drive 2, 3 8 89 mm (3.5”) SL or 133 mm (5.
File and Print Server Part Number Description Quantity 8476-81U Netfinity 3000 Pentium III 650 MHz/256 KB L2, 64 MB ECC, 9.1 GB, 40X, PCI/ISA 1 01K1130 64 MB 100 MHz ECC SDRAM DIMM1 1 20L0553 9.1 GB Wide Ultra2 SCSI HDD 1 01K1319 10/20 GB NS Internal SCSI Tape Drive 1 65464AN G54 Color Monitor 15” (348 mm, 13.7” Viewable Image Size), stealth black 1 94G3134 APC Smart-UPS 700 1 1. For a total of 128 MB of system memory.
IBM NETFINITY 3000 Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 3500 M10 Configurator l.) ) ) ai s) ) s ax ID l/Av x) Fan ar d ces A a d/M a , R o t d t M r , / D / D an t P td (To e (S td tra ) (S s, H , S t en (S ) Ul ays ps r iv l, rs Hz ity lot nal em ( Mb a B t o ) ) kD M g u s S t io . n a ( B s i a t s x a , D i il.) K r ( e d e l.) a ( ed d D Qu we ( Op M an ern ai /Ava er ee /M oc he. ) M .
Total Memory Model 11Y All Models Except 11Y 64 MB 64 MB DIMM standard 128 MB 1 x 01K1130 128 MB DIMM standard - 192 MB 1 x 01K1131 1 x 01K1130 256 MB 1 x 01K1131, 1 x 01K1130 1 x 01K1131 or 1 x 01K11321 320 MB 2 x 01K1131 1 x 01K1131, 1 x 01K1130 384 MB 2 x 01K1131, 1 x 01K1130 2 x 01K1131 448 MB 3 x 01K1131 2 x 01K1131, 1 x 01K1130 512 MB 4 x 01K1131 or 2 x 01K11322 3 x 01K1131 or 2 x 01K11321 768 MB 3 x 01K11321 3 x 01K11321 1024 MB (max) 4 x 01K11322 4 x 01K11322 This ta
quality. In the event the standard four-drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is required, an optional, terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). If connecting narrow devices to this cable, additional 68-pin to 50-pin converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.
Netfinity 3500 M10 Tape Options Part Number Description Bays SCSI Supported Interface (bit) Form Factor Termination Included 68/50-pin Converter Incl. Ext. Tape Enclosures1 01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive 2 8 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 Y 3510020 00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive 2 16 Ultra2 LVD 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 N 3510020, 3551001 01K1319 10/20 GB NS Internal SCSI Tape Drive 2,3 8 89 mm (3.5”) SL or 133 mm (5.
An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall).
IBM NETFINITY 3500 M10 Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 4000R Configurator r 1 ) ) il) so ) ) ns ID d) va es ax ax, Fa ar RA l/ A M oc M / d / r , a D n a td td D ot tP ta ) ltr (S (T (S , H ( en bps z) ,S ys l, U m ive itylots rs ) al t a r a e MH o n m 1 ( ( n 1 u D a ,S ag s s KB )R d t io aB (D l) et l) isk di an ce e .
Netfinity 4000R Processor Upgrades Processor Upgrades with 512KB Cache or 256KB Advanced Transfer Cache SMP Support N/A1 Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor N/A1 Netfinity 650 MHz/256 KB Upgrade with Pentium III Processor All 1xY2 51Y2 N/A1 Netfinity 700 MHz/256 KB Upgrade with Pentium III Processor 31Y2 1.The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server.
Netfinity 4000R Power, Monitor & Accessories Part Number Description Power1 94G6667 Power Cable Type A14 (4.3m, 14 ft.)2 94G7448 Power Cable Type C12 (3.7m, 12 ft.)3 94G6666 100-120V Power Distribution Unit4 94G7450 200-240V Power Distribution Unit5 94G6674 APC Smart-UPS 1400RMB6 94G6676 APC Smart-UPS 3000RMB7 37L6861 APC Smart-UPS 5000RMB17 Power Distribution Units (PDU) Uninterruptible Power Supply (UPS) Monitors8 65464AN G54 Color Monitor 15” (348 mm, 13.
IBM NETFINITY 4000R Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 4500R Configurator x) r ) so il) M a ID es va td./ A c A l/ S ro ,R ./ ./ nd ta e ( td td tP ) ta tra 2 (ToD riv (S ,H (S Ul en bps ,S = s ) s y l s , t t z l m y r R ti lo e a isk H na M ua so ) )( an t( ag (M ,S t io il) l) aB D (D es KB ax er an r ne 6 di ar d Qu va ai ed Op er /M oc he ( w e ( .
Netfinity 4500R Memory RDIMM Socket 4 128 MB (1 x 128) Models RDIMM Socket 3 RDIMM Socket 2 RDIMM Socket 1 Std.
Bay Form Factor Height Front Access Usage Part Number Description RPM Height Bays Max. Supported2 Qty. Ultra2 Hard Disk Drives (HDD)1 - 89 mm (3.5”) - Yes Diskette - 133 mm (5.25”) - Yes IDE CDROM 36L9744 Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL 1...6 62 1...3 HS SL1 Yes Open 36L9745 Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL 1...6 62 A, B 133 mm (5.25”) HH2 Yes Open 36L9748 Netfinity 9.
Netfinity 4500R Internal SCSI Cabling Netfinity 4500R contains a DASD backplane supporting three hot-swap, SCA-2 compliant drive bays. The backplane is connected to one of the internal connectors of the integrated Ultra160 SCSI controller through a 16-bit LVD SCSI cable. A single-drop 16-bit SCSI cable is included with the server for attachment from the second internal Ultra160 connector to a removable media bay device.
Netfinity 4500R Power, Monitor & Accessories Part Number Description Part Number Description Power1 37L6880 Rack and NetBAY1 Netfinity 270 W Hot-Swap Redundant Power Supply Uninterruptable Power Supply (UPS)2 930842P Netfinity Enterprise Rack 930842X Netfinity Enterprise Expansion Cabinet 94G6674 APC Smart-UPS 1400RMB3 9306900 Netfinity Rack 94G6676 APC Smart-UPS 3000RMB3 9306200 Netfinity NetBAY22 37L6861 APC Smart-UPS 5000RMB4 Monitors5 28L3644 Space Saver II Keyboard 3, 5 6331B2N
Netfinity 4500R Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
IBM Netfinity 5000 Configurator il) x ) ) s) ) or ) ID va M a an rd ss ax D, F nda RA tal/A td/ ce , M o / S r a o ( D ta / ) td ltr (T ve ) td tP yy (S s, H l, S (S , U ys ri en bps = dd z) ity Slot iona al Ba k D m rs ) H t R m M u ( e o ( g (M an r, t B il) a il) (D dia D is (m pt ss x) na ne v va Qu we (O te ed oce e (K /M a le r e d E) r M a ther l/ A t a l/ A l y ( Po c y r h pe r o l le M H a r Da d ID a p r c t P o ( S l n t t t be p m a S E f b al o a r p a o n ( c e u T o C a T m o a M d t o y d r
Netfinity 5000 Memory Total Memory1 RDIMM Socket - J15 Models 1...3xY Model 4...6xY 64 MB 64 MB RDIMM Standard 128 MB 1 x 01K7241 128 MB RDIMM Standard Std.
Bay Form Factor Height Front Access Usage A 133 mm (5.25”) HH1 Yes Open2 B 133 mm (5.25”) HH1 Yes IDE CDROM C 89 mm (3.5”) SL Yes 1...5 HS1 SL3 Yes Part Number Description Diskette Bay 5 Bay 4 Bay 3 Bay 2 Bay 1 Bays Max. Supported Qty. Internal Hard Disk Drives (HDD) Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD 7200 SL 1...5 5 Diskette 02K0440 Netfinity 18.2 GB Wide Ultra SCSI Hot-Swap SL HDD 7200 SL 1...5 5 Open 02K0441 Netfinity 36.
Slots Supported Storage Controllers1 01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter2 Full 32-bit 1...5 37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter3 Full 32/64-bit 2...5 4 02K3454 PCI Fast/Wide Ultra SCSI Adapter Half 32-bit 1...5 09L2123 Advanced SerialRAID/X Adapter5 Full 32-bit 1...56 01K7297 Netfinity Fibre Channel PCI Adapter Half 32/64-bit 2...
Netfinity 5000 Power, Monitor & Accessories Part Number Description Part Number Power1 10L7007 Netfinity 175 W Redundant Power Supply Uninterruptable Power Supply (UPS)2 10L6972 Netfinity 5000 Rack-to-Tower Conversion Kit 10L7006 Netfinity 5000 Tower-to-Rack Conversion Kit Rack and NetBAY1 94G3135 APC Smart-UPS 1000 94G3136 APC Smart-UPS 1400 930842P 94G6674 APC Smart-UPS 1400 RMB3 930842X Netfinity Enterprise Expansion Cabinet 94G6676 APC Smart-UPS 3000 RMB3 9306900 Netfinity Rack 37
Netfinity 5000 Tape Options Description Part Number Bays Supported SCSI Interface (bit) Form Termination Factor Included 89 mm (3.5”) HH or 133 mm (5.25”) HH 89 mm (3.5”) SL or 133 mm (5.25”) HH 89 mm (3.5”) HH or 133 mm (5.25”) HH 133 mm (5.25”) HH 133 mm (5.25”) FH 133 mm (5.25”) FH 133 mm (5.25”) FH 68/50-pin Converter Incl. Ext.
Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Rack Mounted Application Server Part Number Description Quantity 8659-8RY 10K2165 01K8043 37L6086 36L9806 01K1325 36L9636 65464AN 94G6674 10L7007 Netfinity 5000 Pentium III 700MHz/256 KB L2, 128 MB (R) ECC, Open, 32X, PCI/ISA (Rack 5U) Netfinity 700 MHz/256 KB Upgrade with Pentium III Processor Netfnity 256 MB SDRAM ECC RDIMM1 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter Netfinity 9.
IBM Netfinity 5100 Configurator x) r ) so il) M a ID es va td./ A c A l/ S ro ,R ./ d ./ ta e ( td td tP ) an tra 5 (ToD riv (S ,H (S RD St Ul en bps s ) s y s = , , t t z l l m y r o ti e a isk H M (R na ua so ) Sl an t( ag (M il) l) io aB D r, (D x) es KB an r ne 4 pt di ar d Qu va ai ed er oc he ( we e Ma O l M e / y e r o ( l r .
Netfinity 5100 Memory Total Memory1 Quantity of RDIMMs Added 128 MB (1 x 128) Models RDIMM Socket 4 RDIMM Socket 3 128 MB (33L3123) 256 MB (33L3125) 512 MB (33L3127) 1 GB (33L3129) RDIMM Socket 2 256 MB 1 - - - RDIMM Socket 1 384 MB 2 or 1 - - 512 MB 3 - - - 640 MB - 1 - Std.
Bay Form Factor Height Front Access Usage A 133 mm (5.25”) HH1 Yes Open B 133 mm (5.25”) HH1 Yes Open - 133 mm (5.25”) SL - 89 mm (3.5”) SL C...H SL2 HS Removable Media (RM) Diskette A B CD-ROM 7200 SL C...H 6 Yes 36L9745 Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL C...H 6 Yes Diskette 36L9748 Netfinity 9.1 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD 10,000 SL C...H 6 36L9749 Netfinity 18.2 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD 10,000 SL C..
Netfinity 5100 Internal SCSI Cabling The Netfinity 5100 contains a DASD backplane supporting six hot-swap, SCA-2 compliant drive bays. The backplane is connected to channel A of the intergrated dual-channel, Ultra160 SCSI controller connector through a 16-bit LVD SCSI cable. If internal RAID support is required, this cable can be used to connect to a supported RAID adapter rather than the integrated SCSI controller. No external SCSI port is included.
Netfinity 5100 Power, Monitor & Accessories Part Number Description Part Number Power1 33L3760 Netfinity 250 W Hot-Swap Redundant Power Supply2 37L6881 Netfinity Hot-Swap Power Supply Expansion Kit3 37L6858 Netfinity 5Ux24D Tower-to-Rack Kit Rack and NetBAY1 Uninterruptable Power Supply (UPS)4 94G3135 APC Smart-UPS 1000 930842P 94G3136 APC Smart-UPS 1400 930842X Netfinity Enterprise Expansion Cabinet 94G6674 APC Smart-UPS 1400RMB5 9306900 Netfinity Rack 94G6676 APC Smart-UPS 3000RMB5
Netfinity 5100 Tape Options Part Number Tape Drives Bays Supported SCSI Interface (bit) Form Termination Factor Included 68/50-pin Converter Incl. Ext. Tape Enclosures 89 mm (3.5”) HH or 133 mm (5.25”) HH 133 mm (5.25”) FH 133 mm (5.25”) FH 133 mm (5.
A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing environment, but doesn’t require the high end performance and fault tolerance properties of larger servers. The sample configuration above consists of an IBM Netfinity 5100 with 256 MB of memory (expandable to 4 GB) and 45.5 GB of hard disk space.
IBM NETFINITY 5100 Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 5500 Configurator r .) ) so ) ns a il a x es D) d) a c r A I l/Av d/M F o ) a r , R d t M M P , a D 9 M / n / t t M (S ) td ta td tra To HD y) DI en ps (S (S Ul ys ( ives ,S s, d y H z) =R em (M b l, rs ) al r ty ot a R i l a g o n md ( M ( D t t u B s S B x.) na ne D t io a (m ed an r, es ( K il) a il) isk r( di M a er te Op Qu owe oc e . v pe Ma va lle Me rd D E) m Et h r y( / A a l/ A Da r S P r ach td.
Total Memory DIMM Models 8660-11U, 1RU, 41U, 4RU, 51U, 5RU 128 MB 128 MB DIMM Standard 192 MB 1 x 01K8022 256 MB 1 x 01K8023 RDIMM Models 8660-61U, 6RU RDIMM Models 8660-42U, 4SU, 52U, 5SU, 62U, 6SU, 7xU 128 MB RDIMM Standard - - RDIMM Slot 1 - J4 - 1 x 01K7262 RDIMM Slot 2 - J3 256 MB RDIMM Standard 384 MB 2 x 01K8023 1 x 01K8043 1 x 01K7262 RDIMM Slot 3 - J2 512 MB 3 x 01K8023 1 x 01K7262, 1 x 01K8043 1 x 01K8043 RDIMM Slot4 - J1 640 MB 2 x 01K8043, 1 x 01K72621 2 x 01K8043
1. Two half-high (HH) bays can be combined to support a single full-high device. 2. Two slim-line (SL) bays can be combined to support a single half-high device. 3. One NetBAY3 is included with tower models and a total of three are supported. See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.
Part Number Description Adapter PCI Length Support IBM NETFINITY 5500 Netfinity 5500 I/O Options Slots HotSupported1 Plug2 Storage Controllers3 01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter4, 5 Full 32-bit 1...6 X 37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6 Full 32/64-bit 1...6 X 02K3454 PCI Fast/Wide Ultra SCSI Adapter Half 32-bit 1...6 - 09L2123 Advanced SerialRAID/X Adapter Full 32-bit 1...67 - Half 32/64-bit 1...
Netfinity 5500 Power, Monitor & Accessories Part Number Description Part Number Power1 01K7951 94G3136 Conversion Kits Netfinity 400 W Hot-Swap Redundant Power Supply II2 37L6860 Netfinity 8Ux24D Rack-to-Tower Kit1 Uninterruptible Power Supply (UPS)3 01K8021 Netfinity 5500 Rack-to-Tower Kit2 APC Smart-UPS 1400 37L6859 Netfinity 8Ux24D Tower-to-Rack Kit9 01K8020 Netfinity 5500 Tower-to-Rack Kit 930842P Netfinity Enterprise Rack 1400RMB4 94G6674 APC Smart-UPS 94G6676 APC Smart-UPS 3000RM
IBM NETFINITY 5500 Netfinity 5500 Tape Options Part Number Description Bays Supported SCSI Interface (bit) Form Factor Termination 68/50- pin Ext. Tape Included Converter Encl.1 Incl. 01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive A, B 8 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 Y 3510020 00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive A,B 16 Ultra2 LVD 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 N 3510020, 3551001 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive A, B 16 133 mm (5.
Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements. High Availability Part Number 8660-72U 01K8053 01K1320 7852400 01K7951 10L6912 94G6674 65464AN Description Quantity Netfinity 5500 (Pentium III 550/128 MB, Tower & NetBAY3) Netfinity 9.
Two Node High Availability Cluster CH3 CH2 LAN IBM NETFINITY 5500 Public ServeRAID-3HB (37L6086) Server Node A 10/100 Ethernet (34L1501) CH1 Integrated10/100 Ethernet (03K9311) (25’ Ethernet Crossover Cable1) Netfinity EXP 15 Server Node B CH3 CH2 CH1 Integrated10/100 Ethernet ServeRAID-3HB (37L6086) 10/100 Ethernet (34L1501) Public LAN 1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
IBM Netfinity 5500 M10 Configurator or ) il) x ) s) ss ) ID 2 ) d) va an a ce ax ) ar ax R A al/A d/M ,F o d r M M , D M / n t t / d IM t P s) ta td tra (To e (S HD y) l St D n S S y , ( ( e U s ) l, s ys riv y dd m bp l, =R ot Hz or ) na m tit R Ba k D g e (M ua l) Sl (M ess ( KB )( t io ai (m an r, (D di a il) na net x is p d u e a r e c .
Netfinity 5500 M10 Memory RDIMM Slot 1 - J4 RDIMM Slot 2 - J3 Models 8661-1...
Bay Form Factor Height Front Access Usage SL Yes Diskette - 89 mm (3.5”) - 133 mm (5.25”) HH Yes IDE CDROM A 133 mm (5.25”) HH1 Yes Open B 133 mm (5.25”) HH1 Yes 1...6 HS SL2 Yes NB33 19” Rack 3U Yes Diskette CD-ROM Bay A Bay B Hot Swap (HS) Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Description RPM Height Bays Max. Supported Qty. Internal Hard Disk Drives (HDD) 01K8053 Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD 7200 SL 1...6 6 02K0440 Netfinity 18.
Netfinity 5500 M10 I/O Options Part Number Description Adapter PCI Slots HotLength Support Supported1 Plug2 Full 32-bit 1...6 X Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6 Full 32/64-bit 1...6 X 02K3454 PCI Fast/Wide Ultra SCSI Adapter Half 32-bit 1...6 - 09L2123 Advanced SerialRAID/X Adapter Full 32-bit 1...67 - 01K7297 Netfinity Fibre Channel PCI Adapter Half 32/64-bit 1...
Netfinity 5500 M10 Power, Monitor & Accessories Part Number Description Part Number Power1 01K7951 Conversion Kits Netfinity 400 W Hot-Swap Redundant Power Supply II2 37L6860 Netfinity 8Ux24D Rack-to-Tower Kit1 Uninterruptible Power Supply (UPS)3 01K8021 Netfinity 5500 Rack-to-Tower Kit2 94G3136 APC Smart-UPS 1400 37L6859 Netfinity 8Ux24D Tower-to-Rack Kit9 94G6674 APC Smart-UPS 1400 RMB4 01K8020 Netfinity 5500 Tower-to-Rack Kit 94G6676 APC Smart-UPS 3000 RMB4 37L6861 RMB5 APC Smart-U
Netfinity 5500 M10 Tape Options Description Bays Supported SCSI Interface (bit) Form Factor Termination 68/50- pin Ext. Tape Included Converter Encl.1 Incl. 01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive A, B 8 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 Y 3510020 00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive A, B 16 Ultra2 LVD 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 N 3510020 3551001 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive A, B 16 133 mm (5.
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and redundant UPSs for power even during a blackout or in the event of a UPS or power cord failure, this server represents the leading edge in high availability.
Two Node Node High High Availability Availability Cluster Cluster Two Public Public LAN LAN Server Node Node A A Server ServeRAID-3HB ServeRAID-3H (01K7207) (37L6086) CH2 CH1 CH2 CH1 10/100 Ethernet Ethernet (34L0901) (34L1501) 10/100 CH3 CH3 SCSI Quorum Link Integrated10/100 Ethernet Ethernet Integrated10/100 (03K9311) (03K9311) (25’ Ethernet Ethernet (25’ Crossover Cable Cable11)) Crossover Netfinity EXP EXP 15 15 Netfinity Server Node Node B B Server CH1 CH3 CH2 CH3 CH2 CH1 (37L6086) ServeRAID-
IBM Netfinity 5500 M20 Configurator 7 so r ) il) ) ID ) va ax a ) ro ar ax RA al/A d/M , d P M M , D M / n t t / t ) a d M D a 2 d r o S y n I t t ( t H T y e ) St S s) (S e Ul y s ( RD m s, dd Hz bp y( l, rs a l, r iv ot m R= ge tit (M (M ua a B a k D so B) Sl on an a )( l) a il) (m n i t s , d D x t a r ( e s i ai e K e e i a rn Op m M at Qu er Med d D Av l/Av oc he ( we pe /M ( ) l / e r l l D o r d S y E a ot a th r (P cy ro ar or ppl te f P ac al St be le ot ( ID p nt ct so m ys an dE lH ro C y( ( T
Netfinity 5500 M20 Memory Total Memory1 RDIMM Slot 1 Std.
Bay Form Factor Height Front Usage Access Part Number Description RPM Height Bays Max. Supported Qty. Internal Hard Disk Drives (HDD) - 89 mm (3.5”) SL Yes Diskette - 133 mm (5.25”) HH Yes IDE CDROM 01K8053 Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD 7200 SL 1...6 6 A 133 mm (5.25” HH1 Yes Open 02K0440 Netfinity 18.2 GB Wide Ultra SCSI Hot-Swap SL HDD 7200 SL 1...6 6 B 133 mm (5.25” HH1 Yes Open 02K0441 Netfinity 36.
Netfinity 5500 M20 I/O Options Part Number Description Adapter PCI Slots Length Support Supported1 Hot-Plug2 1...4 X 32/64-bit 1...4 X 37L6889 Netfinity ServeRAID-4H Ultra160 SCSI Controller6 Full 32/64-bit 1...4 X 02K3454 PCI Fast/Wide Ultra SCSI Adapter Half 32-bit 1...5 - 09L2123 Advanced SerialRAID/X Adapter Full 32-bit 1...4 01K7297 Netfinity Fibre Channel PCI Adapter Half 32/64-bit 1...
Netfinity 5500 M20 Power, Monitor & Accessories Part Number Description Part Number Power1 01K7963 Conversion Kits Netfinity 500 W Hot-Swap Redundant Power Supply II2 37L6860 Netfinity 8Ux24D Rack-to-Tower Kit1 Uninterruptible Power Supply (UPS)3 01K8021 Netfinity 5500 Rack-to-Tower Kit2 94G3136 APC Smart-UPS 1400 37L6859 Netfinity 8Ux24D Tower-to-Rack Kit9 94G6674 APC Smart-UPS 1400 RMB4 01K8020 Netfinity 5500 Tower-to-Rack Kit 94G6676 APC Smart-UPS 3000 RMB4 37L6861 RMB5 APC Smart-U
Netfinity 5500 M20 Tape Options Part Number Description Bays Supported SCSI Interface (bit) Form Factor Termination 68/50- pin Ext. Tape Included Converter Encl.1 Incl. 01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive A, B 8 89 mm (3.5”) HH or 133 mm (5.25”) HH Y2 Y 3510020 01K1319 10/20 GB NS Internal SCSI Tape Drive A, B 8 89 mm (3.5”) SL or 133 mm (5.25”) HH Y2 Y 35100204, 3551001 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive A, B 16 133-mm (5.
Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements. High Availability Part Number Description Quantity Usage 8662-31Y Netfinity 5500 M20 (Pentium III Xeon 500/512 KB 256 MB Tower & NetBAY3) 1 - 01K8053 Netfinity 9.
Two Node High Availability Cluster Public LAN Server Node A CH3 ServeRAID-3HB (37L6086) CH2 CH1 10/100 Ethernet (34L1501) Integrated10/100 Ethernet (03K9311) (25’ Ethernet Crossover Cable1 ) Netfinity EXP 15 Server Node B CH3 CH2 CH1 Integrated10/100 Ethernet (37L6086) ServeRAID-3HB 10/100 Ethernet (34L1501) Public LAN 1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m). Two Node High Availability Cluster Part Number Description Quantity.
IBM Netfinity 5600 Configurator ) ax or l) ) s) ss ai d./M x) ID d) an e v r a A F t c A a M , l/ S ro ,R ./M 6 ./ IM nd ta e ( DD td ) td tP ) ta tra RD 2 (ToD riv (S ,H yy (S Ul en bps ,S = s ) s y l s , t t z l dd m y R ti lo e a is k H or na M m ua )( an t( ag (M ess B) ,S t io il) (m aB D (D l) ax er an r ne di ar d Qu va ai ed roc e (K .
Netfinity 5600 Memory RDIMM Socket 1 (J4) RDIMM Socket 2 (J3) Quantity of RDIMMs Added 128 MB (1 x 128) Models Install largest RDIMM in socket 4 (J1) with subsequent RDIMMs in the following order: J4, J3, J2. RDIMM Socket 3 (J2) RDIMM Socket 4 (J1) Std.
Bay Form Factor Height Front Access Usage A 133 mm (5.25”) HH1 Yes Open B 133 mm (5.25”) HH1 Yes Open - 133 mm (5.25”) HH - 89 mm (3.5”) SL C...H SL2 HS Part Number Description RPM Height Bays Supported Max. Qty. Ultra2 Hard Disk Drives (HDD) 36L9744 Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL C...H 6 Yes IDE CDROM 36L9745 Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL C...H 6 Yes Diskette 36L9746 Netfinity 36.
attach to a supported SCSI adapter if the integrated Ultra2 SCSI controller is utilized for the hot-swap bays. The second channel is available through an industrystandard 0.8-mm very high density connector interface (VHDCI) located on the rear panel for external use. Netfinity 5600 I/O Options Part Number Description Adapter Length PCI Support Slots HotSupported Plug2 Storage Controllers1 01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter 3 Full 32-bit 1...
14. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 5600 works with Netfinity Manager to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management Interconnect Cable Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible. 15.
Netfinity 5600 Tape Options Tape Drives2 Part Number Bays Supported SCSI Interface (bit) 16 Ultra2 LVD2 00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive A, B 01K1319 10/20 GB NS Internal SCSI Tape Drive A, B 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive A, B 01K1320 20/40 GB DLT Internal SCSI Tape Drive A/B 6 00N7990 40/80 GB DLT Internal SCSI Tape Drive A/B 6 Form Termination Factor Included 89 mm (3.5”) HH or 133 mm (5.25”) HH 89 mm (3.5”) SL 8 or 133 mm (5.25”) HH 133 mm 162 (5.
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and UPS for power even during a blackout, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset...data.
IBM NETFINITY 5600 Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
IBM Netfinity 7000 M10 Configurator 3 r ) so ns ) il) ) d) es Fa ID va ax ar ) M c , / 8 d o M D /M d RA al/A r n t ) d , D M a P y t d t S 2 ) H y t ra (To DI St (S St ) y( s, dd e n b p s U lt e =R s rs tit a l, Hz ot m r iv (R emt (M al, ay an Sl (M sso B ) on (m ) g D i , u u B t x r a p e n rne (D ed oce a te (K sk il) ia il) yQ (O e /M r Di pe Da ow M a he er ed va va pl or (P cy M E) al r S of P ach (S td rd m E t troll l/A al/A r ct up n D a o e e a p e a w I S l t C a t d t s ( r F b y a n r s r l
Total Memory1 Model 1RU All Models (except 1RU and x1Y)) 128 MB 256 MB 384 MB 512 MB 640 MB 768 MB 896 MB 1024 MB 1408 MB 1536 MB 2048 MB 3072 MB 4096 MB 5120 MB 6148 MB 8 GB (max) 4 x 32MB DIMMs Std. 1 x 01K8044 1 x 01K8045 3 x 01K8044 1 x 01K8044, 2 x 01K8045 4 x 01K80453, 4 2 x 01K8045, 2 x 01K80462, 4 4 x 01K8045, 2 x 01K8046, 1 x 01K80042, 4 4 x 01K8044, 4 x 01K8046, 1 x 01K80045, 6 4 x 01K8045, 4 x 01K8046, 1 x 01K80045, 6 8 x 01K8046, 1 x 01K80045, 6 4 x 64MB DIMMs Std.
Netfinity 7000 M10 Hard Disk Drive (HDD) Storage Total Internal Storage1 7200 RPM Hard Disk Drives (HDDs) 9.1 GB 0 GB 18.2 GB 10,000 RPM HDDs 36.4 GB 9.1 GB Standard on Base Models 9.1 GB 1 x 01K8053 - 18.2 GB 2 x 01K8053 or 1 x 02K0440 27.2 GB 3 x 01K8053 36.4 GB 4 x 01K8053 or 2 x 02K0440 or 1 x 36L9806 2 x 36L9806 or - 54.6 GB - 3 x 02K0440 72.8 GB (max) - 4 x 02K0440 or 18.2 GB 36.
Part Number Description IBM NETFINITY 7000 M10 Netfinity 7000 M10 I/O Options Adapter PCI Slots HotLength Support Supported1 Plug2 Storage Controllers3 1...12 X 02K3454 PCI Wide Ultra SCSI Adapter Half 32-bit 1...12 - 09L2123 Advanced SerialRAID/X Adapter Full 32-bit 1...12 9 - Full Length Adapter Slots / Power Supply Bays 32/64-bit 1...
15. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 8660 1...4xU are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection. 16.
Netfinity 7000 M10 Tape Options Part Number Description Bays SCSI Supported Interface (bit) 01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive N/A2 8 01K1319 10/20 GB NS Internal SCSI Tape Drive N/A2 8 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive N/A2 16 2 01K1320 20/40 GB DLT Internal SCSI Tape Drive N/A 04K0149 35/70 GB DLT Internal SCSI Tape Drive N/A2 00N7990 40/80 GB DLT Internal SCSI Tape Drive N/A2 32G3918 SCSI-2 16-bit Active Terminator 3510020 3551001 10L7113 3503BOX Exte
Sample Configurations The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Two Node High Availability Cluster LAN IBM NETFINITY 7000 M10 Public Server Node A ServeRAID-3HB (37L6086) CH3 CH2 CH1 10/100 Ethernet (34L1501) 10/100 Ethernet (34L1501) (03K9311) (25’ Ethernet Crossover Cable1) Netfinity EXP 15 Server Node B CH3 CH2 CH1 10/100 Ethernet (34L1501) ServeRAID-3HB (37L6086) 10/100 Ethernet (34L1501) Public LAN 1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
IBM Netfinity 7100 Configurator ) ax or l) ) s) ss ai d./M ID d) an e v r A F t c A a , l/ S ro ,R ./ ./ nd ta e ( DD td td tP ) ta tra 2 ( ToD riv (S ,H (S Ul en bps ,S = s ) s y l s , t t z l m y r R ti lo e a is k H na M ua so ) )( an t( ag (M ,S tio il) aB D (D l) es KB ax er an rne di ar d Qu va ai ed Op er /M oc he ( w e ( .
Netfinity 7100 Memory Set 1- J1 Std. RDIMM Set 2- J2 Set 3- J3 Set 1- J9 Set 2- J10 Set 3- J11 Set 4- J12 Std. RDIMM 64 MB (33L3067) 128 MB (33L3113) 256 MB (33L3115) 512 MB (33L3117) 1 GB (33L3119) 256 MB 4 x 64 RDIMMs Standard - - - - 512 MB 4 - - - - 768 MB - 4 - - - 1.0 GB 4 4 - - - 1.2 GB - - 4 - - 1.7 GB - 4 4 - - 2.0 GB 4 4 4 - - 2.7 GB - 4 - 4 - 3.0 Gb 4 4 - 4 - 3.2 GB - - 4 4 - All RDIMMs installed in each set must be the same 3.
Netfinity 7100 Hard Disk Drive (HDD) Storage Total Int. Storage1 7200RPM Hard Disk Drives (HDDs) 9.1 GB (P/N 36L9744 or 37L7201)2 0 GB 10,000RPM Hard Disk Drives (HDDs) 18.2 GB 36.4 GB 9.1 GB 18.2 GB 36.4 GB (P/N 36L9745 or (P/N 36L9746 or (P/N 36L9748 or (P/N 36L9749 or (P/N 36L9750 37L7202)2 37L7203)2 37L7204)2 37L7205)2 or 37L7206)2 Standard on Base Models Standard on Base Models 9.1 GB 1 - - 1 - - 18.2 GB 2 1 - 2 1 - 27.3 GB 3 - - 3 - - 36.4 GB 4 2 1 4 2 1 45.
Form Factor Height Front Access Usage - 89 mm (3.5”) SL Yes Diskette - 133 mm (5.25”) HH Yes IDE CDROM RM 1 133 mm (5.25”) HH1 Yes RM 2 133 mm (5.25”) HH1 1...10 or 1...7 HS NB33 19” Rack Max. Qty. Ultra2 Hard Disk Drives (HDD) SL See diagram 10 Open 36L9745 7200 SL See diagram 10 Yes Open 36L9746 Netfinity 36.4 GB Wide Ultra2 SCSI Hot-Swap HDD 7200 HH2 See diagram 7 SL or HH2 Yes Open 36L9748 Netfinity 9.
Internal SCSI Cabling The Netfinity 7100 contains a DASD backplane supporting ten hot-swap, SCA-2 compliant drive bays. The backplane is connected to Channel B of the integrated dual-channel, Wide Ultra2 SCSI controller through a 16-bit LVD SCSI cable. Channel A only supports external SCSI attachment and is cabled directly to the external 0.8mm VHDCI SCSI connector. To support devices in the internal 133/89-mm (5.25/3.
15. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 7100 works with Netfinity Director to provide significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management Interconnect Cable Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible. 16.
1. Netfinity 7100 includes two 250W hot-swap redundant power supplies, with the ability to accept up to two additional Netfinity 250 W Hot-Swap Redundant Power Supplies (P/N 33L3760). Each power supply includes its own 9-foot power cord for attachment to a low voltage UPS, PDU or wall outlet. To assist in determining when an additional power supply is required to preserve redundancy, a “Non-Redundant LED” is a standard feature of the Netfinity 7100.
Netfinity 7100 Sample Configurations Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
IBM Netfinity 7600 Configurator ) ax or l) ) s) ss ai d./M ID d) an e v r A F t c A a , l/ S ro ,R ./ ./ nd ta e ( DD td td tP ) ta tra 2 ( ToD riv (S ,H (S Ul en bps ,S = s ) s y l s , t t z l m y r R ti lo e a is k H na M ua so ) )( an t( ag (M ,S tio il) aB D (D l) es KB ax er an rne di ar d Qu va ai ed Op er /M oc he ( w e ( .
Netfinity 7600 Memory Quantity of RDIMMs Added2 Total Memory1 Set 1- J1 Std. RDIMM Set 2- J2 Set 3- J3 Set 1- J9 Set 2- J10 Set 3- J11 Set 4- J12 128 MB (33L3113) 256 MB (33L3115) 512 MB (33L3117) 1 GB (33L3119) 512 MB 4 x 128 RDIMMs standard - - - Std. RDIMM 1.0 GB 4 - - 1.5 GB - 4 - - 2.0 GB 4 4 - - 2.5 GB - 8 - - 3.0 GB 4 - 4 - 4 GB 4 4 4 - 5 GB 4 - 8 - size , but all the sets do not have to contain RDIMMs 6 GB3 - 8 8 - of the same size .
Netfinity 7600 Hard Disk Drive (HDD) Storage Total Int. Storage1 7200RPM Hard Disk Drives (HDDs) 9.1 GB (P/N 36L9744 or 37L7201)2 0 GB 10,000RPM Hard Disk Drives (HDDs) 18.2 GB 36.4 GB 9.1 GB 18.2 GB 36.4 GB (P/N 36L9745 or (P/N 36L9746 or (P/N 36L9748 or (P/N 36L9749 or (P/N 36L9750 37L7202)2 37L7203)2 37L7204)2 37L7205)2 or 37L7206)2 Standard on Base Models Standard on Base Models 9.1 GB 1 - - 1 - - 18.2 GB 2 1 - 2 1 - 27.3 GB 3 - - 3 - - 36.4 GB 4 2 1 4 2 1 45.
SL 0 HH 0 1 Removable Media (RM) Bays 2 3 4 4 5 Diskette 9 CD-ROM Bay 1 10 8 10 Hot-Swap (HS) Bays 10 x SL -or7 x HH (SCSI IDs shown) 11 12 13 Bay 2 14 14 36L9750 Netfinity 36.4 GB 10K-3 Wide Ultra2 SCSI Hot-Swap HDD 10,000 HH2 Ultra160 Hard Disk Drives (HDD) See diagram 7 1 37L7201 Netfinity 9.1 GB Ultra160 SCSI Hot-Swap SL HDD 7200 SL See diagram 10 37L7202 Netfinity 18.2 GB Ultra160 SCSI Hot-Swap SL HDD 7200 SL See diagram 10 37L7203 Netfinity 36.
Netfinity 7600 I/O Options Part Number Description Adapter Length PCI Support Slots HotPCI MHz Supported1 Plug 2 Voltage Key Storage Controllers3 37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter4 Full 32/64-bit 3...65 X 5 33 02K3454 PCI Fast/Wide Ultra SCSI Adapter Half 32-bit 3...6 - 5 33 37L6080 Netfinity ServeRAID-4M Ultra160 SCSI Controller6, 18 Full 32/64-bit 1...6 X Universal 33 37L6889 Netfinity ServeRAID-4H Ultra160 SCSI Controller7, 18 Full 32/64-bit 1...
Slot 1- Bus A- 66 MHz- 3.3 V or Universal Slot 2- Bus A- 66 MHz- 3.
2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate. 3. Height is 3U. See “Rack and NetBAY” for supported IBM racks. 4. Height is 5U. See “Rack and NetBAY” for supported IBM racks. 5. Netfinity 7600 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory. 6. Installation within a rack requires optional Monitor Compartment (P/N 94G7444). 7.
Rack 9306200 28L0542 94G6667 94G7447 94G6670 Netfinity NetBAY22 Netfinity Console Server Selector Switch (4-port) Power Cable- Type A14 12ft Console Cable Set Blank Filler Panel Kit 1 1 1 1 1 This rack server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without.
IBM Netfinity 8500R Configurator 3 ) ) or ) ns ) il) ax ss d) ax Fa ID va /M ) ar ce . , d / o M d D l/A ./M RA . r n t d , a d D M a P S t t t I 2 ) H t D St tra (S (S y( To ) s, en bps e Ul =R tit s( rs a l, Hz ot (R r iv em t (M an ay ) Sl a l, (M sso on ) g D i u , B u B t x r a p D a e n r ne ed oce (K sk il) ia il) yQ r( (O e r Di pe .
Netfinity 8500R Memory Total System Memory1 Standard Models 256 MB 512 MB (2 x 128) (4 x 128) 384 512 640 768 896 1024 1152 1280 1408 1536 1664 1792 2304 2560 2816 3072 3328 3840 4096 4352 4864 5376 5888 6400 8192 8448 9472 10496 11520 12544 13568 14592 16384 (max) 640 768 896 1024 1152 1280 1408 1536 1664 1792 1920 2048 2560 2816 3072 3328 3584 4096 4608 5120 5632 6144 6656 8192 8704 9728 10752 11776 12800 13824 14848 16384 (max) Quantity of RDIMMs Added 128 MB (20L0245) 1 2 or 3 4 or 5 6 or 7 8 or 9 10
Netfinity 8500R Hard Disk Drive (HDD) Storage Total Internal Storage1 7200 RPM Hard Disk Drives (HDDs) 0 GB 10,000 RPM HDDs 18.2 GB 36.4 GB (P/N 36L9745 or (P/N 36L9746 or 37L7202)2 37L7203)2 9.1 GB (P/N 36L9744 or 37L7201)2 9.1 GB 18.2 GB 36.4 GB (P/N 36L9748 or (P/N 36L9749 or (P/N 37L7206) 37L7204)2 37L7205)2 Standard on Base Models Standard on Base Models 9.1 GB 1 - - 1 - 18.2 GB 2 1 - 2 1 - 36.4 GB - 2 1 - 2 1 72.
1. Ultra160 HDDs are limited to a maximum of Ultra2 bus speeds. 2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section. 3.
. Netfinity 8500R I/O Options Part Number Description Adapter Length PCI Support Slots Supported1 HotPlug2 PCI Voltage Key MHz Storage Controllers3 01K7364 Netfinity ServeRAID-3L Ultra2 SCSI Adapter4 Full 32-bit (1...5, 10...12)8 X 5 33 19K0564 Netfinity ServeRAID-3L Ultra2 SCSI Adapter II4 Full 32-bit (1...5, 10...12)8 X 5 33 37L6086 Netfinity ServeRAID-3HB Ultra2 SCSI Adapter5 Full 32/64-bit (1...5, 10...
17. Netfinity 8500R ships standard with a Netfinity Advanced System Management PCI Adapter. 18. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem connection (Netfinity 5500 models 8660-1...4xU are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft).
. Netfinity 8500R Tape Options Part Number Description Bays SCSI Supported Interface (bit) Form Factor 89 mm (3.5”) HH 16 Ultra2 LVD or 133 mm (5.
Sample Configurations The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Two Node High Availability Cluster Public LAN Server Node A ServeRAID-3HB (37L6086) CH3 CH2 CH1 10/100 Ethernet (34L1501) 10/100 Ethernet (34L1501) (2 m cable std. (03K9311) (25’ Ethernet Crossover Cable1 ) Netfinity EXP200 on EXP200) Server Node B CH3 CH2 CH1 10/100 Ethernet (34L1501) ServeRAID-3HB (37L6086) 10/100 Ethernet (34L1501) Public LAN 1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
i ac B (G ty p le Ca la b e g a H) or x St a l, D al ot pe t x n y r : T te (W ys m In Ba ns te ys p io ys um s a a s m b w en lB xi m Su t-S ta Ma Di To Ho IBM STORAGE EXPANSION UNIT IBM External Storage Expansion Unit Overview ) ai av Pa r u tN m be r r Fo m c Fa r to ly t. pp .W fg Su C r x. we Ma Po 35202RU Netfinity EXP15 Ultra SCSI1 10 10, 10 364 447 mm x 571.5 mm x 128.8 mm (17.6 in. x 22.5 in. x 5.1 in.) Rack Drawer (3U) 38.3 kg (84.
IBM Netfinity EXP15 (3520-2RU) Configurator Netfinity EXP15 Hard Disk Drive (HDD) Storage Total Internal Storage1 7,200 RPM Hard Disk Drives (HDDs) 9.1 GB 0 GB 18.2 GB 36.4 GB 10,000 RPM Hard Disk Drives (HDDs) 9.1 GB Standard on all Base Models 18.2 GB 2 x 01K7959 or 1 x 01K8501 36.2 GB 4 x 01K7959 or 2 x 01K8501 or 54.6 GB 6 x 01K7959 or 3 x 01K8501 72.8 GB 8 x 01K7959 or 4 x 01K8501 or 91.0 GB 10 x 01K7959 or 5 x 01K8501 18.2 GB 36.
Cables and Controllers: See Appendix D: Cables - Storage Units - Controllers Sample Configurations The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
IBM Netfinity EXP200 (35301RU) Configurator Netfinity EXP200 Hard Disk Drive (HDD) Storage Total Int. Storage1 7200RPM Hard Disk Drives (HDDs) 9.1 GB (P/N 36L9744 or 37L7201)2 0 GB 10,000RPM Hard Disk Drives (HDDs) 18.2 GB 36.4 GB 9.1 GB 18.2 GB 36.4 GB (P/N 36L9745 or (P/N 36L9746 or (P/N 36L9748 or (P/N 36L9749 or (P/N 36L9750 37L7202)2 37L7203)2 37L7204)2 37L7205)2 or 37L7206)2 Standard on Base Models Standard on Base Models 9.1 GB 1 - - 1 - - 18.2 GB 2 1 - 2 1 - 27.
Form Factor Height Front Access Usage Bus Odd #s HS HH yes open 1 Even #s HS HH yes open 2 2 x 0.8mm VHDCI Connectors Netfinity EXP200 1 3530-1RU Part Number Description RPM Height Bays Supported Max. Qty. Ultra2 Hard Disk Drives (HDD) 36L9744 Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL 1...10 10 36L9745 Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD 7200 SL 1...10 10 36L9746 Netfinity 36.4 GB Wide Ultra2 SCSI Hot-Swap HDD 7200 HH 1...
Cable Length (Meters)1 Ultra2 Controller Maximum MB/s Ultra Controller 1 and 2 80 40 3 80 20 4.3 80 20 12 and 20 80 N/A 1. The EXP200 ships with a single Ultra2 SCSI cable similar to Netfinity 2 M Ultra2 SCSI Cable (P/N 03K9310). Cables and Controllers: See Appendix D: Cables - Storage Units - Controllers Sample Configurations The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
IBM Netfinity EXP300 (35311RU) Configurator Netfinity EXP300 Hard Disk Drive (HDD) Storage Total Int. Storage1 7200RPM Hard Disk Drives (HDDs) 9.1 GB (P/N 36L9744 or P/N 37L7201)2 0 GB 18.2 GB (P/N 36L9745 or P/N 37L7202) 2 10,000RPM Hard Disk Drives (HDDs) 36.4 GB (P/N 37L7203) 9.1 GB (P/N 36L9748 or P/N 37L7204)2 Standard on Base Models 18.2 GB (P/N 36L9749 or P/N 37L7205)2 36.4 GB (P/N 37L7206) Standard on Base Models 18.2 GB 2 1 - 2 1 - 36.4 GB 4 2 1 4 2 1 54.
Netfinity EXP300 1 35311RU 2 x 0.8mm VHDCI Connectors Selectable Bus Configuration 2 x 7 bays 1 x 14 2 bays Ultra2 and/or Ultra160 HDDs 3 Auto Termination SCSI IDs 0...6 SCSI IDs 8...14 37L7205 Netfinity 18.2 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD6 10,000 SL 1...14 143 37L7206 Netfinity 36.4 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD6 10,000 SL 1...
EXP300 Sample Configurations Netfinity EXP300 One Independent SCSI Bus SERVER Netfinity EXP300 Two Independent SCSI Buses To configure as two independent 7 bay SCSI buses, attach two external cables from two ServeRAID adapters, in the same or separate servers, to the two external ports of the EXP300. The EXP300 must be set for 2 x 7 bays.
IBM NETFINITY EXP500 IBM Netfinity EXP500 (35601RU) Configurator Netfinity FAStT EXP500 Storage Expansion Total Internal Storage1 10,000 RPM Hard Disk Drives (HDDs) 9.1 GB (P/N 37L6209) 0 GB 18.2 GB (P/N 37L6210) 36.4 GB (P/N 37L6211) Standard on all Base Models 18.2 GB 2 1 - 36.2 GB 4 2 1 54.6 GB 6 3 - 72.8 GB 8 4 2 91.0 GB 10 5 - 109.2 GB - 6 3 145.6 GB - 8 4 182..0 GB - 10 5 218.4 GB - - 6 254.8 GB - - 7 8 291.2 GB - - 327.
Netfinity FAStT EXP5001 Fibre Channel Connectors 35521RU IN OUT Switch IN Loop A Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Bay 7 Bay 8 Bay 9 Bay 10 External: Fibre Channel Internal: Fibre Channel Auto Termination OUT Loop B 1. Housed in a 19" Rack mountable drawer and ships standard with redundant power supplies and two power cables requiring separate power sources.
Updated 04/18/00 IBM Netfinity Fibre Array Solutions Part Number Description Note Ports1, 2 00N68813 01K72973 01K72963 00N6882 35521RU 35261RU3 35601RU 2109S08 2109S16 35231RU 35341RU For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
A: A short-wave cable is required for this connection. A cable from Cable Group D is required. B: One of these devices has an integrated optical port but the other requires an optional Short-Wave GBIC (P/N 03K9308) to complete the connection. A cable form Cable Group D is required. C: One of these devices has an integrated optical port but the other requires an optional or available Short-Wave GBIC (P/N 03K9308) to complete the connection. A cable from Cable Group D is required.
Netfinity FAStT500 Mini Hub 00N6882 Netfinity FAStT Host Adapter 00N6881 GBIC Ports Netfinity FAStT Host Adapte • PCI to FCAL 66 MHz 64-bit with 32-bit slot compatibility • Supports FC to SCSI and IP Protocols • Supports FC to arbitrated loop public loop profile GBIC • Provides additional connections to the Netfinity FAStT500 RAID Controller - supports complex clustering or advanced storage applications.
Fibre / Fibre Configuration Examples - Cable Group () Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Netfinity Fibre Channel PCI Adapter (P/N 01K7297) Netfinity Fibre Channel RAID Controller Unit (P/N 35261RU) Netfinity Fibre Channel PCI Adapter (P/N 01K7297) Standard Fibre Channel RAID Controller Netfinity Fibre Channel Failsafe RAID Controller Opt.
Fibre / SCSI Configuration Examples- Cable Group () Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements. RAID Unit (P/N 35261RU) Fibre Channel Adapter1 EXP200 Std. RAID Controller Fibre Channel Adapter1 RAID Unit (P/N 35261RU) Std. RAID Controller FFibre Channel Adapter1 Opt.
IBM Netfinity Fibre Array Solutions Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
IBM Netfinity Fibre Array Solutions Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
IBM Netfinity Fibre Array Solutions Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements Cluster Solution High speed multiple node Microsoft Cluster Service (MSCS) and Netfinity Fibre Channel Storage configuration offering data protection and RAID redundancy.
IBM Netfinity Fibre Array Solutions Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
IBM Netfinity NetBAY3/NetBAY3E Stackable Enclosures Installation Guidelines: 1) Locate power units with line cords in the bottom enclosure. 2) Install components starting from the bottom; start with the heaviest device. 3) If nothing is installed in the enclosure, attach the rear blank panel for stability. Sample Configuration Netfinity 7000 M10 36 in. 914 mm NetBAY3 Networking 36 in. 36 in. 19 in. UPS 6 in. 3.2 ft2 36 in. 914 mm 26 in. 19 in x 24 in. 483 mm x 610mm Front 6 in. 20 in.
IBM Netfinity NetBAY3/3E Stackable Enclosure Tower Models Monitor/ Keyboard1 Netfinity 5500, 5500 Mxx Single NetBay and Casters Add Options Add Options Std. NetBAY32 Std.
IBM NETFINITY RACK CABINET IBM Netfinity Rack Cabinet and Options Note: For a robust rack configurator application access URL http://www.ibm.com/pc/us/products/server/download.html.
Optional Accessories Part Number Mounting Support Rack Space Units Supported Fixed Shelf: width x depth= (439 mm x 663mm) 17.3 in. x 2 to xx U 26.1 in max. weight= (45 kg)100lbs.
Power Support Rack Space Comments 100-120V 12a Power Distribution Unit -- 8 NEMA 5-15R outlets Mounts in rack side wall D,C 94G7450 200-240V 16a Power Distribution Unit -- 10 IEC 320-C13 outlets Mounts in rack side wall D,C 94G6674 94G6675 1400VA UPS 120V 220-240V US/C/LA 3U EMEA/AP 6 NEMA 5-15R outlets 4 IEC 320-C13 outlets 94G6676 94G6677 3000VA UPS 120V 120-240V US/C/LA 3U EMEA/AP 8 NEMA 5-15R outlets 8 IEC 320-C13 and 1 C19 94G6667 94G7448 Power Type A14 C12 94G6666 Part Number 94G6
Netfinity Rack - Cabinet and Options Dimensions 9306-900 and NetBAY22 (9306-200) 42 in. 1067 mm 36 in. 914 mm 26 in. 660 mm Dimensions for NetBAY22 (9306-200) 30 in. 762 mm 36 in. 914 mm 23.6 in. 600 mm Front View 12 in. 305 mm 25.5 in. 648 mm Dimensions for NetBAY22 (9306-200) 42U Top View 22U 5.6 ft. 2 .52m2 90 in. 2286 mm 81.5 in. 46.25 in. 2070 mm 1175 mm 34.5 in. 876 mm (23.5 in. x 34.in.) (597mm x 864mm) Side Stabilizers not required on a NetBAY22 (9306-200) 30 in. 762 mm 60 in.
IBM NETFINITY RACK CABINET Updated 04/18/00 For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive 01K1319 10/20 GB NS Internal SCSI Tape Drive 01K1325 20/40 GB 8-mm Internal SCSI Tape Drive 01K1320 20/40 GB DLT Internal SCSI Tape Drive 04K0149 35/70 GB DLT Internal SCSI Tape Drive 00N7990 40/80 GB DLT Internal SCSI Tape Drive MB Te r m in at io 68 nI /5 0 nc -p l. in C In o n te ve rn r te al rI Ca nc bl l. es Da I n ta / C clu le de a n in g d Ca Ex r tr t. id Ta ge pe s En cl os ur es 1 pr 2 .
Te r Ex te SC nt ro lle rs Ca In r tr cl. i Cl dg ea es ni st ng d Ca ./m Ca r tr ax rt id r id ge Qt g e y. Ma ss of gs td dr . st ive d. s/m ax s Ma td ./m x GB ax -N at ive /C om MB pr /s e es cse d Na ti v e /c om pr 1 . M68 M68 M68 Diff Diff Diff Diff Desktop 4U Rack 6U Rack 6U Rack - B B B B - Y Y N Y Y Y - M68-M68 3 M68-M68 3 Jumper 4.5 4.5 4.
Appendix C: UPS Runtime Estimate (minutes) Servers # Pwr. Cords Std/Max Watts Load Max./Typ.
Total Configuration Runtime Estimator (Time in minutes)1 Tower Rack Mount SU-700iNET SU-1000iNET SU-1400iNET SU-2200iNET SU-1400RMiB 94G4073 94G4074 94G4075 94G4076 94G6675 SU-3000RMiB 94G6677 SU5000RMiB 37L6862 United States Part Number SU-700NET 94G3134 SU-1400RMB 94G6674 SU-3000RMB 94G6676 SU-5000RMB 37L6861 Total Load (Watts) Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes 200 22 38 62 130 45 104 240 250 17 28 4
Appendix D: Cables - Storage Units - Controllers F: M: I: 68: 50: 0.8: 16: 8: Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and column contains Female - External Male - External Internal 16-bit, 68-pin High Density connector 8-bit, 50-pin Centronix Connector 16-bit, 68-pin Very High Density Connection Interface (VHDCI) 0.8 mm connector 16-bit, 68-pin connector 8-bit, 50-pin connector Description the cable group letter which supports the connection.
Updated 04/18/00 F: M: I: 68: 50: 0.8: 16: 8: Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and column contains Female - External Male - External Internal 16-bit, 68-pin High Density connector 8-bit, 50-pin Centronix Connector 16-bit, 68-pin Very High Density Connection Interface (VHDCI) 0.8 mm connector 16-bit, 68-pin connector 8-bit, 50-pin connector the cable group letter which supports the connection.
Appendix E: IBM Serial I/O IBM Serial I/O Adapters IBM Serial I/O Port Module Serial I/O PM16DB Port Module (P/N 37L1418) Serial I/O PM16RJ Port Module (P/N 37L1417) IBM Serial I/O Multiplexer Sets Serial I/O 16RJ Multiplexer Set (P/N 37L1419) •Multiplexer Interface Unit •RJ Expansion Module •Power Supply •Test Cable IBM Serial I/O SST8P DB Adapter (P/N 37L1414) Customer Supplied Unshielded Two-Twisted Pair Cable < 3500’ (1km) IBM Serial I/O SST16P RJ Adapter (P/N 37L1415) IBM Serial I/O Power Suppl
IBM ServicePac for Warranty and Maintenance Options for IBM Netfinity Servers and Server Storage Peripherals With IBM ServicePac for Warranty and Maintenance Options, you can upgrade the service included with your hardware’s original warranty. We offer a number of service options with coverage for parts and labor so that you can choose the package with the service response time that fits your needs. The service period for all options begins with the date of installation of the machine.
Machine Name Machine Service Description* Type* IBM Part Number Electronic Estimated Base Warranty Retail Price Fibre Channel Controller 3526 3 YR 24x7 2-hour service 3 YR 24x7 4-hour service 41L2755 41L2754 $1935 $1290 NetMEDIA Storage Expansion Unit 3551 3 YR 24x7 2-hour service 3 YR 24x7 4-hour service 41L2757 41L2756 $180 $120 Rack/Storage Expansion Unit 9306 (200) 3 YR 24x7 2-hour service 3 YR 24x7 4-hour service 41L2759 41L2758 $255 $168 9306 (900) 3 YR 24x7 2-hour service 3 YR 24x
. IBM ServicePac for SmoothStart Services for IBM Netfinity Servers IBM ServicePac for SmoothStart Services are installation services designed to help accelerate the productive use of IBM solutions. Now you don't have to worry about pulling valuable in-house resources from essential daily activities. An IBM services specialist gives you customized service and helps by instructing your technical staff on the basics of each task.
Important Notes IBM reserves the right to change product specifications and to discontinue marketing products without notice. *MHz only measures microprocessor internal clock speed, not application performance. Many factors affect application performance. **When referring to hard drive capacity, GB stands for one billion bytes.Total user-accessible capacity may vary depending on operating environments. ***The quotation function within OrderBUILER allows reseller specific pricing to be included.