User Manual

PRIME / ProArt / TUF GAMING AMD 600 Series BIOS Manual
27
Custom Algorithms
Customize your own algorithms to adjust boosting behavior for more optimized power
efficiency, temperatures, and performance. Customize up to 3 concurrent algorithms.
Algorithm 1-3
Set to [Enabled] to customize this algorithm.
Configuration options: [Auto] [Enabled] [Disabled]
The following items appear only when Algorithm 1 is set to [Enabled].
Algorithm 1-3 Condition
Select the condition to monitor for and take action upon. When multiple Algorithms
watch for the same condition then the result is ‘AND’ and the smaller of the 2 Action
Values get written.
Configuration options: [Auto] [CPU Temperature] [Core Voltage] [Core Current]
Algorithm 1-3 Action
Select the action to take when targeted condition crosses the threshold. When
multiple Algorithms execute the same Actions, then the result is ‘AND’ and the smaller
of the 2 Action Values get written.
Configuration options: [Auto] [Package Power Limit Fast] [Package Power Limit Slow]
[Thermal Limit] [Vcore TDC Limit] [Vcore EDC Limit] [SOC TDC Limit] [SOC EDC
Limit]
Level 1 Threshold Value
Set the boundary separating the Level1 Action Value and Level2 Action Value. When
condition is below or equal to this value, then Level1 Action Value gets written. If
above but below Level2 Threshold Value, then Level2 Action Value gets written.
Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere.
Configuration options: [Auto] [0] - [65000]
Level 2 Threshold Value
Set the boundary separating the Level2 Action Value and Level3 Action Value. When
condition is below or equal to this value and above Level1 Threshold Value, then
Level2 Action Value gets written. If above, then Level3 Action Value gets written.
Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere.
Configuration options: [Auto] [0] - [65000]
Level 1 Action Value
Set the value for Action to take when condition lies below the first boundary. Power in
in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is in MHz.
Configuration options: [Auto] [0] - [65000]
Level 2 Action Value
Set the value for Action to take when condition lies between the first boundary and
second boundary. Power in in Watt, Temperature in degrees Celsius, Current is in
Ampere, and BCLK is in MHz.
Configuration options: [Auto] [0] - [65000]
Level 3 Action Value
Set the value for Action to take when condition lies above the second boundary.
Power in in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is
in MHz.
Configuration options: [Auto] [0] - [65000]