User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Basic Installation
- Chapter 3: BIOS Setup
- 3.1 Knowing BIOS
- 3.2 BIOS setup program
- 3.3 My Favorites
- 3.4 Main menu
- 3.5 Ai Tweaker menu
- 3.6 Advanced menu
- 3.6.1 CPU Configuration
- 3.6.2 PCH Configuration
- 3.6.3 PCH Storage Configuration
- 3.6.4 System Agent Configuration
- 3.6.5 USB Configuration
- 3.6.6 Platform Misc Configuration
- 3.6.7 Onboard Devices Configuration
- 3.6.8 APM Configuration
- 3.6.9 Network Stack Configuration
- 3.6.10 HDD/SDD SMART Information
- 3.6.11 Intel(R) Ethernet Controller - 00:1E:99:00:01:1B
- 3.6.12 Intel(R) Ethernet Controller - 00:1E:99:00:01:1C
- 3.7 Monitor menu
- 3.8 Boot menu
- 3.9 Tool menu
- 3.10 Exit menu
- 3.11 Updating BIOS
- Chapter 4: Software Support
- 4.1 Installing an operating system
- 4.2 Support DVD information
- 4.3 Software information
- 4.4 AI Suite 3
- 4.4.1 Dual Intelligent Processors 5
- 4.4.2 TPU (Turbo Processing Unit)
- 4.4.3 Turbo App
- 4.4.4 EPU (Energy Processing Unit)
- 4.4.5 Fan Xpert 4
- 4.4.6 PC Cleaner
- 4.4.7 DIGI+ Power Control
- 4.4.8 Ai Charger+
- 4.4.9 USB 3.1 Boost
- 4.4.10 EZ Update
- 4.4.11 System Information
- 4.4.12 Mobo Connect
- 4.4.13 USB BIOS Flashback
- 4.4.14 Push Notice
- 4.5 Audio configurations
- Chapter 5: RAID Support
- Chapter 6: Multi GPU Support
- Appendix
3-54
Chapter 3: BIOS Setup
Chapter 3
CPU Fan Middle Duty Cycle(%)
Use the <+> or <-> keys to adjust the CPU fan middle duty cycle. The
values range from 20% to 100%.
CPU Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the CPU temperature.
The values range from 20°C to 75°C. The CPU fan will operate at the
minimum duty cycle when the CPU temperature is lower than the limit.
CPU Fan Min. Duty Cycle(%)
Use the <+> and <-> keys to adjust the minimum CPU fan duty cycle. The
values range from 20% to 100%. When the CPU temperature is lower than
the lower limit, the CPU fan will operate at the minimum duty cycle.
Chassis Fan 1-2 Q-Fan Control [Auto]
[Disabled] Disable the Chassis Q-Fan control feature.
[Auto] Detect the type of Chassis Q-Fan installed and automatically switches the
mode control.
[DC mode] Enable the Chassis Q-Fan control in DC mode for 3-pin chassis fan.
[PWM mode] Enable the Chassis Q-Fan control in PWM mode for 4-pin chassis fan.
The following items appear only when you set the Chassis Fan 1-2 Q-Fan Control to
[Auto], [PWM Mode], and [DC Mode].
Chassis Fan 1-2 Q-Fan Source [CPU]
The assignment fan will be controlled according to the selected temperature source.
Conguration options: [CPU] [MotherBoard] [PCIEX16_1 Slot] [PCIEX16_3 Slot]
[VRM] [PCH] [T_SENSOR1] [EXT_Sensor1] [EXT_Sensor2] [EXT_Sensor3] [Multiple
Sources]
• For EXT_Sensor1-3, connect a Thermistor cable to the EXT_TS1-3 header then place
the other end to the component to get the temperature.
• For Multiple Sources, select up to three temperature sources and the fan will
automatically change based on the highest temperature.
• ASUS FAN EXTENSION CARD is required to congure these items.
Chassis Fan 1-2 Step Up [0 sec]
This item allows you to set the value of the chassis fan step up.
Conguration options: [0 sec] [12 sec] [25 sec] [51 sec] [76 sec] [102 sec] [127 sec]
[153 sec] [178 sec] [204 sec]
Chassis Fan 1-2 Step Down [0 sec]
This item allows you to set the value of the chassis fan fan step down.
Conguration options: [0 sec] [12 sec] [25 sec] [51 sec] [76 sec] [102 sec] [127 sec]
[153 sec] [178 sec] [204 sec]
Chassis Fan 1-2 Fan Speed Low Limit [200 RPM]
This item allows you to disable or set the chassis fan warning speed.
Conguration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]