User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Basic Installation
- Chapter 3: BIOS Setup
- 3.1 Knowing BIOS
- 3.2 BIOS setup program
- 3.3 My Favorites
- 3.4 Main menu
- 3.5 Ai Tweaker menu
- 3.6 Advanced menu
- 3.6.1 CPU Configuration
- 3.6.2 PCH Configuration
- 3.6.3 PCH Storage Configuration
- 3.6.4 System Agent Configuration
- 3.6.5 USB Configuration
- 3.6.6 Platform Misc Configuration
- 3.6.7 Onboard Devices Configuration
- 3.6.8 APM Configuration
- 3.6.9 Network Stack Configuration
- 3.6.10 HDD/SDD SMART Information
- 3.6.11 Intel(R) Ethernet Controller - 00:1E:99:00:01:1B
- 3.6.12 Intel(R) Ethernet Controller - 00:1E:99:00:01:1C
- 3.7 Monitor menu
- 3.8 Boot menu
- 3.9 Tool menu
- 3.10 Exit menu
- 3.11 Updating BIOS
- Chapter 4: Software Support
- 4.1 Installing an operating system
- 4.2 Support DVD information
- 4.3 Software information
- 4.4 AI Suite 3
- 4.4.1 Dual Intelligent Processors 5
- 4.4.2 TPU (Turbo Processing Unit)
- 4.4.3 Turbo App
- 4.4.4 EPU (Energy Processing Unit)
- 4.4.5 Fan Xpert 4
- 4.4.6 PC Cleaner
- 4.4.7 DIGI+ Power Control
- 4.4.8 Ai Charger+
- 4.4.9 USB 3.1 Boost
- 4.4.10 EZ Update
- 4.4.11 System Information
- 4.4.12 Mobo Connect
- 4.4.13 USB BIOS Flashback
- 4.4.14 Push Notice
- 4.5 Audio configurations
- Chapter 5: RAID Support
- Chapter 6: Multi GPU Support
- Appendix
ASUS X99-E-10G WS
3-55
Chapter 3
Chassis Fan 1-2 Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust
depending on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan
operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following items appear only when you set Chassis Fan 1-2 Prole to [Manual].
Chassis Fan 1-2 Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the Chassis Fan 1-2
temperature. The values range from 20 to 75.
Chassis Fan 1-2 Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum Chassis Fan 1-2 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Chassis Fan 1-2 will operate at the maximum
duty cycle.
Chassis Fan 1-2 Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the Chassis Fan 1-2
temperature. The values range from 20 to 75.
Chassis Fan 1-2 Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the middle Chassis Fan 1-2 duty cycle.
The values range from 20% to 100%. When the CPU temperature reaches
the middle limit, the Chassis Fan 1-2 will operate at the middle duty cycle.
Chassis Fan 1-2 Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the Chassis Fan 1-2
temperature. The values range from 20 to 75. The Chassis Fan 1-2 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Chassis Fan 1-2 Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum Chassis Fan 1-2 fan duty
cycle. The values range from 0% to 100%. When the CPU temperature is
under the limit, the Chassis Fan 1-2 will operate at the minimum duty cycle.
Water Pump Control [Disabled]
[Disabled] Disable the Water Pump control feature.
[Auto] Detect the type of Water Pump installed and automatically switches the
mode control.
[DC mode] Enable the Water Pump control in DC mode for 3-pin Water Pump.
[PWM mode] Enable the Water Pump control in PWM mode for 4-pin Water Pump.